User manual ACR ELECTRONICS RCL-300

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ACR ELECTRONICS RCL-300. We hope that this ACR ELECTRONICS RCL-300 user guide will be useful to you.


ACR ELECTRONICS RCL-300 : Download the complete user guide (650 Ko)

Manual abstract: user guide ACR ELECTRONICS RCL-300

Detailed instructions for use are in the User's Guide.

[. . . ] The RCL-300A searchlight contains a narrow beam searchlight that produces 1, 000, 000 peak candle power by combining twin 35W metal halide HD lamps providing over 500K candela (CD) each and 1 million effective CD when combined. All functions of the searchlight can be electrically operated by remote control from the pilot area od the vessel using the URP-102 Point PadTM, URC Master Controller and interconnect cable supplied with the RCL-300A. Searchlights equipped with the URC-300 Master Controller have a self-park feature and ACR's unique XRCiZTM feature. The XRCiZTM feature routinely operates all moving parts in the searchlight to keep the motors and drive mechanisms freely running. [. . . ] Limit the total length of all coax cable used to 300 feet. Y1-03-0232D 6 SECTION 5 - URC-300 MASTER CONTROLLER Mounting The Master Controller can be mounted in any position near the searchlight that is protected from the weather. Check in advance that the coax cable from the Point Pad and the wiring harness from the searchlight can be routed to this location. General wiring scheme WARNING: The RCL-300 has a unique wiring scheme. The Master Controller is supplied with an in-line fuse-holder on the Orange power lead. WARNING: Failure to follow this arrangement may damage components. Master Controller Wire Orange Blue Yellow Green Red White Black Brown White Black Yellow Green Red White Black Brown White Black Searchlight Cable Wire Wire Gauge (AWG) 16 16 16 16 16 16 16 16 12 12 Power Source Lead +12 VDC or +24 VDC** Ground Function URC-300 Power URC-300 Ground Position Sensor Signal Position Sensor Common Up Down Right Left Lamp Power Lamp Ground Table 1 WARNING: This wire MUST be fused with a 30 amp fuse in the Master Controller's in-line fuse-holder. Y1-03-0232D 7 Wiring to the searchlight The RCL-300A searchlight is supplied with a 15-foot integral wire harness. If you must lengthen the wire harness, use heavy duty wire to minimize the voltage drop. This is especially important for the WHITE 12 AWG lamp power, BLACK 12 AWG lamp ground, ORANGE power wire and BLUE ground wires. use the supplied butt connectors to connect the Master Controller to the searchlight. Wiring the Point PadTM The RG-59 coax cable is supplied without the "F" connectors attached for ease of routing. After the Coax cable has been routed, strip the insulation and crimp the "F" connectors in place. Screw the "F" connectors to the Master Controller and the Point PadTM. Wiring to the power supply Figure 5 The power source must be a fused 12 VDC, 30-amp supply or a 24 VDC, 15amp supply. Following the wiring scheme in Table 1, use the supplied butt connectors to connect the Master Controller to the power source. Refer to Table 2 for proper wire size for connection of the input power lines. NOTE: As per the wiring scheme, the ORANGE wire is connected to the positive terminal and the BLUE wire is connected to the negative terminal of the power source. CAUTION: HID light systems, when first turned on, have a high inrush current requirement of 25 amps. If you activate the light and the lamps flicker on and off repeatedly, check the voltage being supplied. This condition can be experienced with voltage input of less than 11. 5V. Functions of the URC-300 The URC-300 Master Controller is designed to perform up to six different duties on searchlights, winches and other electrical devices. The Master Controller provides optimum voltage to ensure brightest performance and long lamp life, regardless of boat system voltage fluctuations. The Master Controller is compatible with devices requiring 12 VDC through 24 VDC operation. Y1-03-0232D 8 The URC-300 Master Controller has a searchlight motor time-out feature. If a Point PadTM rotation switch (right or left) is continually engaged for more than 50 seconds, the Master Controller will interrupt the operation until the Point Pad switch is disengaged. [. . . ] To ensure that you have the most recent version of the Product Support Manual, please visit the ACR website at www. acrelectronics. com. Reproduction in whole or in part is permitted only with permission of ACR Electronics, Inc. Ongoing product improvements may change product specifications without notice. Trademarks or registered trademarks are the property of their respective owners. Y1-03-0232D 14 EC DECLARATION OF CONFORMITY ACR Electronics, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ACR ELECTRONICS RCL-300




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ACR ELECTRONICS RCL-300 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.