User manual ADE LOGIC 6

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADE LOGIC 6. We hope that this ADE LOGIC 6 user guide will be useful to you.


ADE LOGIC 6 : Download the complete user guide (2144 Ko)

You may also download the following manuals related to this product:

   ADE LOGIC 6 BROCHURE (141 ko)
   ADE LOGIC 6 ENGINEERING INFORMATION (1863 ko)

Manual abstract: user guide ADE LOGIC 6

Detailed instructions for use are in the User's Guide.

[. . . ] Intruder alarm system Engineering Information 1 2 3 4 5 6 TA PA ZONE Power Learn Error Day Accenta/!mini LGSIX/01 Logic Six panel with two pre learnt Keyfobs The above intruder system is designed to comply with the installation requirements of BS 4737 1986/87. 4188-753 issue 1_1/03 1 Downloaded from: http://www. guardianalarms. net Engineering information Contents Features - - - - - - - - - - - - - - - - Installation Design - - - - - - - - - - - Fixing the control panel - - - - - - - - Wiring the system - - - - - - - - - - - Tamper network - - - - - - - - - - - - Security zones - - - - - - - - - - - - - PA circuit - - - - - - - - - - - - - - - Extension speaker - - - - - - - - - - - External siren Output (Bell box) - - - - 13V Supply output - - - - - - - - - - - Set - - - - - - - - - - - - - - - - - - Factory set condition - - - - - - - - - - Zone Function - - - - - - - - - - - - - First Power up - - - - - - - - - - - - - Mains Connection - - - - - - - - - - - Testing the system - - - - - - - - - - - System indications - - - - - - - - - - - Programs - - - - - - - - - - - - - - - Walk tests - - - - - - - - - - - - - - - Alarm tests - - - - - - - - - - - - - - How to learn new keyfobs - - - - - - - How to re-learn all keyfobs - - - - - - - How to learn keyfobs if non are recognised Re-arm - - - - - - - - - - - - - - - - Alarm Cycle Counter- - - - - - - - - - Faults - - - - - - - - - - - - - - - - - Specification- - - - - - - - - - - - - - Servicing organisation Details - - - - - Parts - - - - - - - - - - - - - - - - - 2 3 3 4 4 5 6 7 8 9 9 10 10 11 11 12 12 12 13 13 14 15 16 17 17 18 19 20 20 Features ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ 6 Security zones PA input Tamper input Outputs for External siren (Bell) and Strobe Pre-configured Part set program selectable by DIP switch. Entry Time duration selectable by DIP switch Entry Deviate Alarm Cycle Counter Strobe confirmation on Set Memorises first and subsequent zone intrusions in one alarm period Walk Test facilities by push button control Alarm Test facilities by push button control Battery capacity of up to 2. 1Ah Up to 8 keyfobs can be used with the panel (2 Keyfobs supplied pre learnt) Learn mode to learn new keyfobs Erase mode to disable lost or stolen keyfobs 2 4188-753 issue 1_1/03 Logic Six intruder system Installation Design The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding following the procedures and advice contained in this manual. [. . . ] Repeat to learn the new keyfob. x 2 beeps Power Day Once all the keyfobs are recognised `learnt' by the Panel wait for just over 10 seconds for the Panel to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication. 14 4188-753 issue 1_1/03 Logic Six intruder system How to re-learn all keyfobs Using a recognised learnt keyfob the Panel can re-learn up to 8 keyfobs. You may want to do this after a keyfob is lost or stolen and you want to prevent the use of it to operate the system. Keyfobs must be learnt by each Panel installed in a system By entering the learn mode in this manner you will erase all recognition of previously learnt keyfobs at the Panel, except for the one used to enter the learn mode. Power Day Ensure the Panel is in the day mode with the Day LED lit. You must have one learnt keyfob and up to 7 further keyfobs to be learnt. When an unrecognised keyfob is offered to the Panel it will cause the Error LED to be lit and continuous sound to be emitted from the local sounder. Hold for 20 seconds Panel Learnt keyfob keyfob recognised beep Learn 1 2 3 x 5 rapid beeps Hold the recognised `learnt' keyfob slighty touching the centre depression on the Panel and keep it there without movement for 20 seconds. Initially you will hear a keyfob recognition beep and 10 seconds later five rapid beeps from the local sounder. After another 10 seconds you will hear 5 rapid beep tone from the local sounder. The Learn LED will give a flashing indication and the ZONE 1 LED changes from flashing to steady On indication to recognise the learnt keyfob. The Panel is now ready to learn the next keyfob, signalled by the ZONE 2 LED flashing. In the learn mode when an already learnt keyfob is offered to the Panel, an Error indication will be given. The learn mode will timeout after 10 seconds if no actions is taken to learn the next keyfob Learn 1 2 x 5 rapid beeps Panel Next keyfob Offer the next keyfob slightly touch it on the centre depression of the Panel. A learnt indication is given of the next keyfob when the flashing ZONE LED changes to steady On indication and there is a recognition beep given by the local sounder. You now have up to 10 seconds to start learning another keyfob. keyfob recognised beep Learn 1 2 3 x 2 beeps Power Day Repeat to learn the next keyfob. Once all the keyfobs are recognised `learnt' by the Panel wait for just over 10 seconds for the Panel to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication. 4188-753 issue 1_1/03 15 Engineering information How to learn keyfobs if none are recognised You will only need to learn keyfobs in this manner if no keyfobs are recognised by the Panel. A Panel can learn up to 8 keyfobs following power up of the intruder system. Keyfobs can be learnt by each Panel installed in a system J6 1 ZONE + TA SCB Ensure the Panel is connected to the intruder system and the link is fitted on the Panel PCB between Z1 and Set. STROBE DB + BELL SET - Power up the intruder system you will hear five rapid beeps to acknowledge the Panel is in the Learn mode. The learn mode will NOT timeout until the first keyfob is learnt. POWER UP THE SYSTEM x 5 rapid beeps Learn 1 Panel Hold first keyfob keyfob recognised beep Hold the first keyfob slightly touching it on the centre depression of the Panel. Once the first keyfob is acknowledged by the Panel the ZONE 1 LED changes from flashing to steady and there is a recognition beep given by the local sounder. The Panel is now ready to learn the next keyfob, signalled by ZONE 2 LED flashing. Learn 1 2 Panel Next keyfob keyfob recognised beep Offer the next keyfob slightly touching it on the centre depression of the Panel. A learnt indication is given of the next keyfob when the flashing ZONE LED changes to steady On indication and there is a recognition beep given by the local sounder. You now have up to 10 seconds to learn the next keyfob. Learn 1 2 3 x 2 beeps Power Day Repeat to learn the next keyfob. Once all the keyfobs are recognised `learnt' by the Panel wait for just over 10 seconds and the Panel will exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication. Now remove the link between Z1 and Set. 16 4188-753 issue 1_1/03 Logic Six intruder system NVM Error A Non Volatile Memory NVM error indication is given by a flashing Error LED. If an NVM error occurs then you will need to re-learn all the keyfobs, see page 16. Alarm Cycle Counter An alarm cycle is considered as the duration of an alarm from trigger to the end of 20 minutes operation of the external siren. [. . . ] Ensure that pets do not have access to the protected areas as they can cause a false alarm, unless pet immune detectors have been used, ask your installer for more information. Power Day The Day indicator should be lit at the Panel. Offer a keyfob to the Panel and withdraw it as soon as you hear the keyfob recognition beep tone from the local sounder. Panel Offer keyfob to the Panel and withdraw Note the panel LEDs will flash consecutively from right to left, PA to Zone1 LED during Set operation. If however there is an open zone then the relevant ZONE LED will be lit and a sound indication is given. If this is the case then investigate the cause and ensure all zones are closed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADE LOGIC 6




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADE LOGIC 6 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.