User manual ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE. We hope that this ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE user guide will be useful to you.


ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE : Download the complete user guide (1598 Ko)

Manual abstract: user guide ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions for: Grade A and B Central Station Burglary, Grade A Proprietary Burglary, Grade A Local Burglary, Grade A Police Station Connected Burglary, Central Station Fire, Household Fire, Household Burglary, and Combination Household Fire & Burglary Systems (P/N: AVR PLUS) P/N 09820450 Revision A See the Advantage plus Service Manual (P/N 09820460) for operational theory and service procedures. See the SONICS Database Management Manual (P/N 09820426) for options programming procedures. ___________________________________________________________ Copyright © 1997 by Advantor Corporation. All rights reserved. No part of this document may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of Advantor Corporation. GLOSSARY OF ADVANTAGE plus TERMS Access Module - Access Modules are Base Module add-on units that provide facility access control. Each Access Module controls up to four facility doors, provides ten general purpose alarm loops and six auxiliary outputs. [. . . ] Install the 1KEOL resistors at the farthest point from the Base Module in each active alarm loop, in parallel with an alarm-on-short sensor. To meet UL requirements for annunciation supervision, unique fire sound, and power limit, the annunciators must be wired as shown on sheet 2 of Figure 7. The Wheelock MT annunciators must be set for "Code 3" pattern, or the Wheelock AS or AH sounders used with Wheelock DSM synchronizers. The relay connects between Bell (+) and the Base Module auxiliary output optioned with the Independent Zone Bell option. The Tamper alarm loop supervises the annunciator output, sending a Tamper alarm if the annunciator circuit is cut or shorted. The Tamper alarm is ignored if it is received with a FIRE alarm. Auxiliary Outputs (J4 Pins 5 Through 12) Base Module J4 pins 16 through 19 (labeled AX1- through AX4and their respective +12 outputs) are the Base Module's four Auxiliary Outputs. You may daisy-chain external device power from one "+12" line, but home run the "AX1-" through "AX4-" lines from the Base Module. NOTE: If optioned for Enable Line Monitor 2, the AX4 output is automatically dedicated to the line monitor feature. The current drawn by existing devices (i. e. , sensors and keypads) determines the current available for auxiliary devices. If the current is available, each auxiliary output can control up to 100mA. BASE MODULE J5 WIRING Alarm Loop Wiring Base Module jacks J5 and J6 contain the inputs for the Base Module's 16 alarm loops (labeled A1 through A16). NOTE: Certificated UL systems use the 1KEOL assembly from their respective UL Installation Kit. Intrusion Alarm Loop Wiring Power and ground to alarm sensors, detectors or devices requiring auxiliary power must be run on separate wires from the alarm loop. Obtain 24-hour power from Base Module board J2 pins labeled "+12" and "GND" respectively. To provide the required alarm circuit supervision, you must install one of the supplied 1KEOL end-of-line resistors in series with alarmon-open contacts (such as door switches), or in parallel with alarmon-closure contacts. Install the 1KEOL resistors at the farthest initiating device from the Base Module on each of the circuits. NOTE: The Tamper alarm loop does not require a 1KEOL resistor if the loop does not extend outside the Base Module chassis. Fire Alarm Loop Wiring Table 3 lists smoke detectors and other devices compatible with Advantage plus Fire systems. When installing 4-wire smoke detectors you must also install Power Supervision Unit(s). Recommended is the DSI EOL 200 (12VDC), or another UL Listed device of equivalent ratings. Install the power supervisory unit at the sensor farthest from the Base Module on each alarm circuit. Compatible Smoke Detectors and Devices Standby Alarm Manufacturer/Model Current (mA) Current (mA) Detection Systems, DS200-4W 0. 08 25 Detection Systems, DS200HD 0. 08 25 Detection Systems, MB4W 0. 08 48 Detection Systems, MB4WA 0. 08 56 Detection Systems, MB4WE 0. 08 80 Detection Systems, MB4WS 0. 08 63 Detection Systems, EOL200 30 30 Voltage 10-27 VDC 10-27 VDC 10-30 VDC 10-30 VDC 10-30 VDC 10-30 VDC 10-30 VDC OPTIONAL CARD READER WIRING The Base Module can support one access controlled door, but be aware that the access events cannot be uploaded for report generation. The Base Module maximum number of card holders is also restricted to 99 (employees 01-99). The application uses a Base Module auxiliary output for the door lock interface, and the Base Module's existing card reader interface. 8 Dial Telephone Line Connection To House Telephone 5 6 7 8 NOTE : All UL Fire and Burglary installations must use the fused RJ31X jack included in the ULB and ULF Installation Kits. Advantage plus Installation Diagram 11/10/97 WARNING!Electrical shock hazard present during telephone line servicing. UL LISTED POWER LIMITED CIRCUITS: 1. [. . . ] Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment; or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. User's should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. " CAUTION! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADVANTOR ADVANTAGE PLUS-4250 BASE MODULE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.