User manual ADVANTOR ADVANTAGE PLUS-BASE MODULE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADVANTOR ADVANTAGE PLUS-BASE MODULE. We hope that this ADVANTOR ADVANTAGE PLUS-BASE MODULE user guide will be useful to you.


ADVANTOR ADVANTAGE PLUS-BASE MODULE : Download the complete user guide (1144 Ko)

You may also download the following manuals related to this product:

   ADVANTOR ADVANTAGE PLUS-BASE MODULE INSTALLATION INSTRUCTIONS (907 ko)

Manual abstract: user guide ADVANTOR ADVANTAGE PLUS-BASE MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] Base Module The Advantage® plus Base Module is the primary communication processor and control unit for Advantage plus systems. Installed within the protected facilities, it is available in a standard UL version, attack version, or a military J-SIIDS version. [. . . ] Each Base Module can interface and control up to 8 SmartAudio or ListenIn Modules. Dimensions PCB Foot Print · 7. 25" W x 8. 5" H (17. 41cm x 21. 59cm) Audio · DSP processes 8 audio channels for intrusion detection · Each audio channel assignable to any of 8 separate arming partitions · Sensitivity adjustable from central station · 16 audio sensor inputs (two per audio channel) · Programmable audio sensor self-test at system arming and disarming · Balanced audio output to Base Module · Audio sensors annunciate Chime Mode & Entry/Exit Alert Stored Audio · One second pre-impact · Four seconds post-impact, followed by live audio Power Requirements · 200 mA at 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) Operating Environment · 0° F to 122° F (-18° C to 50° C) Communications · Base Module RS-485 Communication link up to 2, 000 feet maximum with 22AWG shielded twisted pair cable Auxiliary Inputs · "No AC" and "Low Battery" inputs to monitor the status of an optional APS12V1A-S Advantage PowerSource · Tamper input Mounting · Mounts locally inside Base Module enclosure or remotely inside optional enclosure up to 2, 000 ft. from Base Module Part Numbers ADV SAM Smart Audio Module with Installation Kit APS12V1A-S Power Supply, 12VDC AVR CHAS/SUR115 Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection AVR CHAS/SUR220 Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection 40003401 Enclosure Tamper Switch Kit 90228102 90237200 90258200 08610416 09820452 PCB, Smart Audio Module Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16. 5VAC, 50VA, Plug-In SmartAudio Module Installation Instructions 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820486, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com Specifications and part numbers are subject to change without notice. Expansion Module The Expansion Module provides the Advantage® plus Base Module with an additional 16 supervised, programmable alarm points, and four additional auxiliary outputs. Each Base Module can interface and control up to 8 Expansion Modules. Dimensions PCB Foot Print · 6. 87" W x 4. 125" H (17. 45cm x 10. 48cm) Alarm Points 16 programmable, supervised, hard-wired points N/C, N/O, or Both (Dry Contact) Programmable alarm codes Programmable into any of 8 separate arming partitions(protected areas) · All alarm points operate normally under ground fault conditions · · · · Operating Environment · 0° F to 122° F (-18° C to 50° C) Auxiliary Outputs · Four, 100mA, programmable hard-wired Communications · Base Module RS-485 Communication link up to 2, 000 feet maximum with 22AWG shielded twisted pair cable Power Requirements · 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) · 130mA maximum in both Normal Standby and Alarm Mounting · One mounts locally inside Base Module enclosure or remotely inside an optional enclosure up to 2, 000 feet from the Base Module Part Numbers Loop Expansion Module with Installation Kit APS12V1A-S Power Supply, 12VDC 90226101 PCB, Expansion Module 90237200 Standard Enclosure with Lock and Key AVR CHAS/SUR115 Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection AVR CHAS/SUR220 Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection ADV LEM 40003401 90258200 08610416 09820453 08061699 08061431 08061206 Enclosure Tamper Switch Attack Enclosure with Lock and Key Transformer, 16. 5VAC, 50VA, Plug-In Loop Expansion Module Installation Instructions AC Surge Protector (120VAC), hardwired AC Surge Protector (220VAC), hardwired Battery, 12V, 7AH Gel Cell 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820483, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com Specifications and part numbers are subject to change without notice. Access Module The Access Module adds access control to the Advantage® plus system. This can be used to provide security in situations where phone lines are unavailable, or to provide backup communication if regular phone service is interrupted. Dimensions PCB Foot Print · 11. 00" W x 8. 0" H (27. 94cm x 20. 32cm) Cellular Interface · Motorola 3 watt, full duplex unit · Communication with cell constantly monitored · Cable length to antenna is 15 feet Operating Environment · 0° F to 122° F (0° C to 50° C) Power Requirements · 12 VDC from Base Module backup battery(s) · 100mA in Normal Standby mode · 1, 600 mA in transmit mode Mounting · Mounts locally inside Base Module enclosure Part Numbers CELLULAR MODULE APS12V1A-S 09820457 90194102 AVRPLUSBASCELKT Cellular Module Complete with Installation Kit Power Supply, 12VDC Cellular Module Installation Instructions PCB, Cellular Interface to Base Module Factory integrated Base Module and Cellular Module, assembled in attack enclosure, with 120 VAC internal transformer. Includes AC "Level 2" surge protection and dial phone line "Level 2" surge protection shown AVR PLUSBASECELLKT shown AVR PLUSCELLKT Factory integrated Base Module, Cellular Module, and SmartAudio Module, assembled in attack enclosure, with 120 VAC internal transformer. Includes AC "Level 2" surge protection and dial phone line "Level 2" surge protection 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820485, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com Specifications and part numbers are subject to change without notice. TelPlus Module For a greater level of security, the TelPlus Module adds a second communication channel, either a dial with line supervision, or a dedicated line to the Advantage® plus system. Dual line capability to meet NFBA 72 4-2. 3-2. 1. 6. Dimensions PCB Foot Print · 2. 625" W x 2. 125" H (6. 67cm x 5. 40cm) Telco Configurations Dial Line · RJ31X jack · Pulse or DTMF dialing · Integrated cut line supervision Dedicated Line · RJ31X jack Operating Environment · 0° F to 122° F (-18° C to 50° C) Power Requirements · 12 Volts DC (from Base Module) · 0 mA in Normal Standby mode, 45 mA in transmit mode Part Numbers TEL PLUS 90227101 09820454 TelPlus Module Complete with Installation Kit PCB, TEL PLUS Module TEL PLUS Module Installation Instructions Mounting · Plugs into the J9 connector on the Base Module 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820484, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com Specifications and part numbers are subject to change without notice. ListenIn Module The ListenIn Module gives the Advantage® plus Base Module the ability to support up to 16 audio verification sensors in any of eight partitions (Advantage AudioSensor or Advantage GlassBreak). Each Base Module can interface and control up to eight ListenIn or SmartAudio Modules. Dimensions PCB Foot Print · 6. 87" W x 4. 125" H (17. 45cm x 10. 48cm) Audio · 16 audio sensor inputs · Audio sensor pairs assignable to eight separate arming partitions (protected areas) · Balanced audio output to Base Module Operating Environment · 0° F to 122° F (-18° C to 50° C) Power Requirements · 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) · 30mA in both Normal Standby and Alarm Communications · Base Module RS-485 Communication link up to 2, 000 feet maximum with 22AWG shielded twisted pair cable Mounting · One mounts locally inside Base Module enclosure or remotely inside optional enclosure up to 2, 000 feet from Base Module Part Numbers ADV LIM APS12V1A-S 90231101 90237200 90258200 08610416 09820455 ListenIn Module with Installation Kit Power Supply, 12VDC PCB, ListenIn Module Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16. 5VAC, 50VA, Plug-In ListenIn Module Installation Instructions AVR CHAS/SUR115 Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection AVR CHAS/SUR220 Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection 08061699 AC Surge Protector (120VAC), hardwired 08061431 AC Surge Protector (220VAC), hardwired 08061206 Battery, 12V, 7AH Gel Cell 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820487, Rev. A 6/98 Specifications and part numbers are subject to change without notice. BLANK 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com Specifications and part numbers are subject to change without notice. Wireless Module The Wireless Module gives the Advantage® plus Base Module the capability to interface with up to 63 supervised, programmable alarm points. Each Base Module can interface and control one Wireless Module. Interface · Inovonics 900 MHZ spread spectrum receiver. Dimensions PCB Foot Print · 5. 125" W x 2. 125" H (13. 02cm x 5. 40cm) Alarm Points · · · · 63 programmable, supervised, wireless points Optional N/C or N/O Programmable alarm codes Each transmitter assignable to any of 8 separate arming partitions (protected areas) Power Requirements · 12 VDC (from Base Module or optional APS12V1A-S Advantage PowerSource) · 250mA maximum in both Normal Standby and Alarm Supervision · Each wireless transmitter supervised for alarm and battery conditions · Wireless receiver is supervised for communications · Wireless transmitters may be supervised for communications (optional) Communications · Base Module RS-485 Communication link up to 2, 000 feet maximum with 22AWG shielded twisted pair cable Operating Environment · 0° F to 122° F (-18° C to 50° C) Mounting · Can be mounted locally inside Base Module enclosure or remotely inside an optional enclosure up to 2, 000 feet from Base Module Part Numbers ADV WIM 90239102 APS12V1A-S 90237200 90258200 08610416 09820456 AVR CHAS/SUR115 Wireless Module with Installation Kit PCB, Wireless Module Power Supply, 12VDC Standard Enclosure with Lock and Key Attack Enclosure with Lock and Key Transformer, 16. 5VAC, 5A, Plug-In Wireless Module Installation Instructions Standard Enclosure, Internal Transformer (120VAC) and AC "Level 2" surge protection Standard Enclosure, Internal Transformer (220VAC) and AC "Level 2" surge protection AC Surge Protector (120VAC), hardwired AC Surge Protector (220VAC), hardwired Universal Transmitter Door/Window Transmitter (1" Gap) Smoke Detector/Transmitter Pendant Transmitter Sharpshooter PIR/Transmitter DS776RF PIR/Transmitter ShatterPro Glass Break/Transmitter Wireless Billtrap 08061345 08061346 08061347 08061348 08061349 Wireless Billtrap for Metal register Universal transmitter (reduced Size) Door/Window Transmitter (5/8" Gap) Beltclip Transmitter, 2 Button Beltclip Transmitter, 1 Button Remote Wireless Receiver Repeater for Extended Range Box w/four 4. 5v Battery Packs for 08061337 Rechargeable 1. 2AH, 12v Battery for 08061351 3v Lithium Battery for 08061343 and 08061346 3. 6v Lithium Battery for 08061340 and 08061341 Optional holster for Pendant Transmitter Assorted lens pack (5) for 08061341 Pet Alley Lens Pack (5) for 08061341 Mirror for 08061341 installation Ceiling Mount for 08061341 Metal cage for PIR Wireless Survey Kit Receivers 08061350 08061351 08061352 08061353 08061354 08061355 08061356 08061357 08061358 08061359 08061360 08061361 08061362 Accessories and Batteries AVR CHAS/SUR220 08061699 08061431 08061337 08061338 08061339 08061340 08061341 08061342 08061343 08061344 Fully-Supervised Transmitters 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820488, Rev. [. . . ] Using in a listen-in only application may enhance the coverage area. Power Requirements · Input Voltage: 10. 2 VDC ­ 14 VDC · Input Current: 5 ma typical Tamper Switch · 500ma at 30 VDC Mounting · Wall mount · Wiring via 6-position Panduit style connector Dimensions · Size: 3. 25" L x 1. 68" W x 0. 75" D (8. 26cm x 4. 27cm x 1. 91cm) · Weight: 1. 56 oz (44g) · Housing: ABS plastic, off-white Part Numbers AUDIOSENSOR 07543002 40013401 AudioSensor Complete PCB, AudioSensor AudioSensor/GBD Backplate to mount to single gang box (package of 6) Ceiling Mounting Bracket Housing Operating Environment · 0° F to 122° F (-18° C to 50° C) 49001501 09001101 Advantage plus GlassBreak Dimensions · Size: 3. 25" L x 1. 68" W x 0. 75" D (8. 26cm x 4. 27cm x 1. 91cm) · Weight: 1. 56 oz (44g) · Housing: ABS plastic, off-white Power Requirements · Input Voltage: 10. 2 VDC ­ 14 VDC · Input Current: 5 ma typical Operating Environment · 0° F to 122° F (-18° C to 50° C) Tamper Switch · 500ma at 30 VDC Part Numbers GBD-ST 90256100 40013401 49001501 09001101 Glass Break Sensor Complete PCB, Glass Break Sensor AudioSensor/GBD Backplate to mount to single gang box Ceiling Mounting Bracket Housing Mounting · Wall mount · Wiring via 6-position Panduit style connector 6101 Lake Ellenor Drive · Orlando, Florida 32809 Tel: 800/ADVANTOR · 407/859. 3350 · Fax: 407/859. 5205 http://www. advantor. com P/N 09820489, Rev. A 6/98 Specifications and part numbers are subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADVANTOR ADVANTAGE PLUS-BASE MODULE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADVANTOR ADVANTAGE PLUS-BASE MODULE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.