User manual ADVANTOR LCD PLUS KEYPAD

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ADVANTOR LCD PLUS KEYPAD. We hope that this ADVANTOR LCD PLUS KEYPAD user guide will be useful to you.


ADVANTOR LCD PLUS KEYPAD : Download the complete user guide (465 Ko)

Manual abstract: user guide ADVANTOR LCD PLUS KEYPAD

Detailed instructions for use are in the User's Guide.

[. . . ] LCD plus Keypad Installation Instructions (P/N: LCD PLUS AVR or LCD PLUS GEN) P/N 09830030 Rev. C See the Advantage 3000 Series Systems Installation and Service Manual or the Advantage plus Service Manual for panel theory and service procedures. See the SONICS Database Management Manual or the Advantage® Access for Windows User's Guide for options programming procedures. Advantage® is a trademark of Advantor Corporation Copyright © 1996-97 by Advantor Corporation. [. . . ] Displayed status messages may include: · low battery · RPU down · memory error · options error · preamp down · cut telephone line Pressing the Quit button returns you to the initial Setup Mode screen (Figure 4). Pressing the Loops button LOOP STATUS displays the status of Loop # 16 shorted system alarm loops (open, tested shorted, normal). The word "tested" appears in Prior Quit the display if the loop was Figure 7. Loop Status Screen tested during a Walk Test (see Figure 7 for an example). While viewing the Loop Status screen pressing Prior displays the previous alarm, pressing Next displays the next alarm. Pressing Quit returns you to the Setup Mode screen (Figure 4). External Beeper Output NOTE: UL requires that there be NO CONNECTION to this output, which goes low while the keypad is beeping. LCD plus KEYPAD SETUP MODE NOTE: Only LCD plus keypad #1 operates while the system is in the Test Mode. Place a system with no options into the Test Mode by powering it up with the TEST/OPER switch (S1) in the TEST position. NOTE: 3350+ and 3250 systems enter Test Mode by powering up with the Tamper loop violated. After power up press "9+8+7+6+ENTER" on the keypad to stay in Test Mode. The keypad displays a SETUP MODE "Waiting for Master Controller" message. HHMM ENTER sets time After approximately 15 select function seconds the LCD plus Test Cal Download keypad displays the Setup Figure 4. LCD Setup Mode Screen Mode screen shown in Figure 4, indicating the system is in the Test Mode. The 3250 system and access modules have no audio detection capabilities. Walk Test WALK TEST From the Test Mode in progress screen, pressing the Walk button places the system in push ENTER when done the Walk Test Mode and Figure 8. Using Walk Test you can perform a functional system test by entering Walk Test then walking around the facility violating alarm loops. After violating the loops return to the keypad and press ENTER to exit the Walk Test. You can press the keypad "*" key (system status) to see the Walk Test results. Pressing "*" displays the TEST RESULT screen shown in Figure 7. Outputs Test SETTING SYSTEM TIME Any time the LCD plus keypad displays the "HHMM ENTER sets time" prompt you may set or change the system clock. With the phone line disconnected, pressing the On button routes audio from all system audio sensors to the TIP and RING test points on the panel. Pressing the Off button removes the audio from the TIP and RING test points. Pressing the Done button returns you to the initial Setup Mode screen (Figure 4). The Auto Calibration screen "calibrated" listing shows the audio detectors that have been calibrated. Using the Calibration Mode screen View command, check the detector(s) sensitivity (see View Calibration). Pressing Done returns you to the Calibration Mode screen (Figure 13). View Calibration Stored Audio Test Audio Calibration From the Calibration Detector number: 1 Mode screen, pressing the Sensitivity: 06 View button places the Prior Quit Next system in the View Mode and displays the View Figure 16. [. . . ] Restore Tamper From the Download Switch to operate Mode screen, pressing the Answer button places the system in the Answer Exit Mode and displays the Figure 21. The Exit button gives you the option of exiting Download Mode and returns you to the initial Setup Mode screen (Figure 4). While at the Answer Mode screen, restoring the Tamper loop (3250 and 3350+ systems) or switching the panel's TEST/OPER switch (S1) back to OPERATE (3450, 3475 and AAM4-C+) prepares the panel for options downloading. The keypad screen clears, then a "Waiting for download" message appears on the bottom display line until the central station computer contacts the panel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ADVANTOR LCD PLUS KEYPAD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ADVANTOR LCD PLUS KEYPAD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.