User manual BOWENS ESPRIT DIGITAL PRO750

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BOWENS ESPRIT DIGITAL PRO750. We hope that this BOWENS ESPRIT DIGITAL PRO750 user guide will be useful to you.


BOWENS ESPRIT DIGITAL PRO750 : Download the complete user guide (1203 Ko)

Manual abstract: user guide BOWENS ESPRIT DIGITAL PRO750

Detailed instructions for use are in the User's Guide.

[. . . ] Voltage Photocell Sounder Power On/Off Switch Figure 1 Modelling Power Control IR Remote Control Guide Number: Full power, 50° Keylite, ISO 100 Flash Colour Temperature Flash Power Control Recommended Modelling Lamp Flash Tube Assembly Dimensions Function Display IR Remote Receiver Flash Duration (Full Power) t=0. 5 1/1100s Approx. 5300K (UV coated) Full to 1/32 5 f-stop in 1/10 increments 250W 120V Halostar 275W 120V Photoflood Clear UV-Coated L =390mm W=170mm H =125mm 3. 0Kg Weight Function Display Controls Lamp Function Control Ready LED Test / Open Flash Figure 2 3. 2kg Due to our policy of constant product improvement Bowens International Limited reserve the right to change equipment specifications without notice. ACCESSORIES For details of all related products please contact your local distributor. 2 15 Esprit Digital Operating Instructions WARNINGS & FAULT FINDING If the unit appears to have developed a fault, first establish that it is a genuine internal fault and not a case of normal operation such as overheat. If no obvious problem can be found and replacement of the modelling lamp, flash tube or fuse does not effect a cure then it is likely that an internal fault has developed. Always return the unit to an authorised service centre if a fault is suspected after these checks. [. . . ] Then insert the umbrella through the hole in the Wide Angle Reflectors mounting bracket and lock in position with the knurled screw. Note: Take care when fitting and removing reflectors/accessories not to damage the flash tube assembly. The flash tube is very delicate, avoid unnecessary handling of the glass tube. Always switch off and disconnect from the supply before changing the flash tube assembly. FAST RECYCLING OPERATION As with any flash unit the useful life of the tube and the unit as a whole depends on the way it is used. The fast recycling feature of the Esprit Digital allows a rapid sequence of high power flashes to be obtained. However, this feature should be used sparingly since continuous rapid flashing can cause overheating and subsequent damage to the flash tube and possibly the internal electronics. Rapid sequences of flashes should always be followed by a reasonable cooling period, at least 10 to 20 minutes is advised either without flashing or at a substantially reduced rate. The unit is equipped with overheat protection, not to limit performance but to prevent damage under abnormal operating conditions. Repeated operation of the overheat protection should be avoided by decreasing the flash power or repetition rate. Dimming or turning the modelling lamp off will help prevent overheating. Whenever possible, avoid rapid high power flashing when using restrictive reflectors such as a snoot or grid reflector, particularly if the unit is pointing downwards. The Modelling Lamp will extinguish while the unit recharges and light again when the unit reaches `READY'. If the unit fails to flash for any reason then the LAMP will not be extinguished. When the unit reaches `READY', after being flashed, the Modelling Lamp will intensify to full brightness and then dim before returning to the previous setting (or to OFF). If the unit fails to flash for any reason then the LAMP will not follow this sequence. In. 0 Function Selection Momentarily press the `FUNCTION' button to scroll through the available functions as follows: Display Range X. X 5. 0 to 10 5. 0 to 10 0 to 12 Description Display Flash power value. Use `UP' or 'DOWN' to select. In. 1 FX. X LX. X CXX Option Selection Press and hold down the `FUNCTION' button for approximately one second until the display changes to show one of the values below. If the SOUNDER is on it will sound continuously while the `FUNCTION' button is held down. Now momentarily press the `FUNCTION' button to scroll through the options until the desired one is reached as follows: Display Range X. X 0. 0. 0 to 9. 9. 9 1 to 9 0 or 1 0 or 1 Description Firmware version. Use `UP' or 'DOWN' to select. X. X. X di. X Fd. X In. X A more detailed explanation of these options is given in the OPTIONS section. 6 11 Esprit Digital Operating Instructions If a transmitter set to a different channel number is activated within range of the unit with the IR Remote enabled then the channel number of that unit will be briefly displayed. This allows a quick channel check to be made whenever a channel number is unknown. The remote control can then be switched to that channel. UP & DOWN Buttons Select the required `FUNCTION' as detailed above. Single presses of the `UP' or `DOWN' buttons will increment or decrement the value by one. [. . . ] The resistive dump will continue to reduce any remaining energy while the unit is off. This safety feature cannot be disabled. LX. X 5. 0 to 10 If no adjustment is attempted within 4 seconds then the display will revert to the default `FLASH' mode. If the value needs to be reviewed or adjusted later then use the `FUNCTION' button to select the `LAMP' mode. The LAMP power is adjustable over a 5 f-stop range (6 f-stops) in 1/10 f-stop increments using the `UP' and `DOWN' push buttons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BOWENS ESPRIT DIGITAL PRO750




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BOWENS ESPRIT DIGITAL PRO750 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.