User manual CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G. We hope that this CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G user guide will be useful to you.


CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G : Download the complete user guide (1524 Ko)

Manual abstract: user guide CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G

Detailed instructions for use are in the User's Guide.

[. . . ] COMBINATION BOILER Heating and Instantaneous Domestic Hot Water Fanned Flue system Installation and Operating instructions These instructions Must Be Left With The Appliance. 2 1 0 bar 3 4 2 1 0 bar 3 4 c Manufactures N° 200906812037. 31 200906812027. 31 200906813037. 31 200906813027. 31 Model Type Britony SE 80 Nat Britony SE 80 L. P. G. Britony SE 100 Nat Britony SE 100 L. P. G. Gas Council N° 47 - 980 - 16 47 - 980 - 18 47 - 980 - 17 47 - 980 - 19 GB IE c These instructions are suitable for the following boilers : Britony Combi SE. Chaffoteaux & Maury supports Benchmark, the heating industry code to ensure the correct installation, commissioning and servicing of domestic central heating systems. To The Householder Make sure you have a completed Log Book for your boiler. [. . . ] 3 pin plug and unswitched socket may be used, provided it is not used in a room containing a bath or shower. It should only supply the appliance. Location The boiler can be installed on any suitable internal wall. Provision must be made to allow the correct routing of the flue and siting of the terminal to allow the safe and efficient removal of the flue products. A compartment or cupboard may be used provided that it has been purpose-built or modified for the purpose. It is not necessary to provide permanent ventilation for cooling purposes. If it is proposed that it is installed in a timber framed building then reference must be made to British Gas Document DM2, or advice sought from CORGI. Flue Detailed information on flue assembly is contained in the appropriate starter pack. The boiler must be installed so that the flue terminal is exposed to the free passage of external air at all times. It must not be allowed to discharge into another room or space such as an outhouse or closed lean-to. The minimum acceptable clearances are shown below: - A Directly below an opening, window, etc - B Above an opening, window, etc - C Horizontally to an opening, window, etc - D Below gutters, soils pipes or drain pipes - E Below eaves - F Below balconies or car port roof - G From a vertical drain pipe or soil pipe - H From an internal or external corner - I Above ground roof or balcony level - J From a surface facing the terminal - K From a terminal facing the terminal - L From an opening in the car port into the dwelling - M Vertically from a terminal on the same wall - N Horizontally from a terminal on the same wall - Q Fixed by Ubbink Rolux 4 GM flue terminal 300 mm 300 mm 300 mm 75 mm 200 mm 200 mm 150 mm 300 mm 300 mm 600 mm 1200 mm 1200 mm 1500 mm 300 mm Q Q I F J B L G A I C H H N M N M D, E Q K Fig. 8 7 Installation Installing the Boiler Method of positioning the boiler on the wall. The paper template can be used to ensure the correct positioning of kitchen cabinets etc. The paper template has to be fixed to the wall and used to locate the position of the hanging bracket, the centre for the flue hole and, if required, the fixings for the pre-piping jig. Drill and plug the wall and secure the hanging bracket using the screws provided. 9 and remove the outer case as shown in fig. 10. Please check that you are familiar with the installation requirements before commencing work. (section 6) The installation kit includes the flue components and the flue installation instructions with the boiler you have the following items : - Hanging bracket - A paper template (showing the dimensions of the boiler with 5 mm side clearances and fitting instructions) - Connection tails - Screws and wall plugs - Connection washers and filters 8 7 Installing the Boiler (continued) 2 3 1 4 0 bar A Fig. 11 for reference, connect the gas and water pipes and the valves to the base of the appliance using the tails provided. There is a 190 mm space between the valves and the wall to make these connections. Connecting the boiler to the system - Hinge down the front panel (fig. 11) to access to the valve connections - Remove the yellow caps and connect the boiler to the taps using washers provided in the plastic bag 3 x fibre washers for the C/H flow, hot water outlet and cold supply inlet 1 x washer mesh filter "F" CH return connection. This can be achieved using a filling loop or other methods approved by the local water authority. F R Fig. It should terminate below the boiler over a tundish or 22 mm pipe (see I fig 12) which should in turn discharge safely outside the premises. Care should be taken that it does not terminate over an entrance or window or where a discharge of heated water could endanger occupants or passers by. [. . . ] A filling loop can be so installed as to be hidden beneath the boiler. System capacity bar) Pf Pression à froid pour le circuit chauffage (enchart Pressure 2, 0 1, 9 1, 8 1, 7 1, 6 1, 5 1, 4 1, 3 1, 2 1, 1 1, 0 0, 9 0, 8 0, 7 40°C 50°C 60°C 70°C 80°C 20 40 60 80 100 120 140 160 180 200 220 240 260 Liters Fig. 21 12 10 User's Instructions 26 25 22 24 23 28 I Control panel 19. 29. 2 1 0 bar 3 29 reset = Domestic hot water temperature adjustment = Heating flow temperature adjustment 27 Green indicator - Power ON Orange indicator - Burner ON Red indicator - Lock out / flame failure Pressure gauge =- DHW mode indicator =- Heating mode indicator 30 20 21 19 Fig. Heating temperature indicator lights 26 "RESET" Reset button Isolating Taps (taps shown in Open position) 30. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CHAFFOTEAUX & MAURY BRITONY COMBI SE 80 L P G will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.