User manual CIAT AQUACIAT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CIAT AQUACIAT. We hope that this CIAT AQUACIAT user guide will be useful to you.


CIAT AQUACIAT : Download the complete user guide (1486 Ko)

Manual abstract: user guide CIAT AQUACIAT

Detailed instructions for use are in the User's Guide.

[. . . ] ­ The group must be perfectly accessable for ease in carrying out maintenance and servicing operations. ­ No obstacle should impede the free circulation of air on the air exchanger (intake and discharge). Sound level : our units have been designed for a low sound level operation. However, when planning the installation, take into consideration the outside environment and the type of building for radiated and transmitted noise (vibrations). [. . . ] In cooling mode, the unit starts as soon as the ambient temperature goes above P09. The ambient box tumbwheel and the outside temperature have no influence on this mode. Note : the cooling mode permits creating a temperature difference of 3 to 5°C between the indoor and outdoor temperature. To install the manual reset thermostat on the unit, you must : 1 - dismount the unit roofing and withdraw the electrical panel door. 2 - fix the 63°C manual reset thermostat on the electrical panel (position 1, next to the 78°C thermostat of the electrical auxiliary devices) For this type of installation, we recommend using the Climbox 2 programme and the cooling/heating floor kit, both of which are available in the catalogue. The cooling/heating floor kit includes : ­ 1 ambient box with ambient temperature adjustment (+/- 3°C) thumbwheel. 4 - fix the thermostat capillary on the water departure copper tube with 2 plastic clips, then cover with the insulation also held in place with 2 plastic clips. Connection recommendations : All the entries must be voltage free and of good quality. ATTENTION : do not connect a phase or a neutral on terminals 7 to 12 of terminal box J2. Plan a shrouded cable connection whose passage will be at least 30 cm distant from all lines succeptible of generating parasites, the shrouding will be connected to the mass at both ends. ­ Common If the heating and cooling entries are supplied simultaneously, the unit goes into stop mode. If the frost-free entry is supplied simultaneously with the heating and/or cooling, the unit goes into frost-free mode If there are several shrouded cables, each shrouding will be connected separately (if a risk of parasite still exists, plan the relay of several entries). Distance superior to 30 meters : Plan relaying the various entries, 1 relay per entry mounted in the vicinity of the electronic card (cables section : 0. Entries : heating/cooling operation ­ building frost free : return water temperature maintained at 30°C ­ electrical auxiliary devices shedding/repowering : closed = shedding ­ remote assistance resetting : in case of level 1 fault, the contact closing permits relaunching the electrical auxiliary devices for 48h heating (while waiting for fault repair). This entry must It offers a fault exit NO/NF (terminal box J2 of the MCAD5) and an automaticity control (terminal box J2 of the MCAD5). Automaticity control : you can connect a potential free contact (ex : clock. ;) between 1 and 2 on the terminal box J2 : closed contact : operation of the unit authorised open contact : unit is stopped. ATTENTION : do not connect a phase or a neutral on terminals 1 and 2 of terminal box J2. The green LEDs correspond to the operation of the associated symbol (compressor running, auxiliary electrical heating or cooling mode). In case of level 1 fault, the key 8 (relaunch) permits relaunching the electrical auxiliary devices for a 48 hours heating period (while waiting for repair). ­ Level 0 fault : automatic restart of the unit after fault acquittal and a time delay ­ Level 1 fault : the unit stops ; It is possible to relaunch the electrical auxiliary devices for a 48hrs heating period (while awaiting for repair). For units fitted with a switch on their supply source, the opening of the electrical door is only possible when the switch is on " off ". [. . . ] Type of fuse => 5 x 20 1A delayed D The card is not supplied with electricity or the voltage is too low, check the presence of 230V between J4. 0 and +5, then between 0 and +NR, then contact your After Sales Department. 15 is on 1 D Check that the AQUACIAT phase is connected to the ClimBox 2 phase D The lights D21 and D22 are indicators of communication with the ClimBox 2, check their state and contact the After-Sales department. (the display lights are off if there is no dialogue) D The voltage drops too much when starting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CIAT AQUACIAT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CIAT AQUACIAT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.