User manual CIAT MICROCIAT MRS 5-1 B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CIAT MICROCIAT MRS 5-1 B. We hope that this CIAT MICROCIAT MRS 5-1 B user guide will be useful to you.


CIAT MICROCIAT MRS 5-1 B : Download the complete user guide (266 Ko)

Manual abstract: user guide CIAT MICROCIAT MRS 5-1 B

Detailed instructions for use are in the User's Guide.

[. . . ] Keys To modify another parameter, press again key Pr , the LED goes off and the display panel indicates again the number of the for access to modified parameter. It permits to unroll in logical order the configuration parameters and to display only the parameters necessary for starting-up the unit. After these 3 seconds, " " display for 2 seconds, then "InSt" display for 2 seconds. Press key Pr modifying the parameter, press keys for validation of the parameter modifications. [. . . ] p00=0 : compressor , fan and electrical devices stopped (possibility of authorizing operation of electrical auxiliary devices for 48h , see remote relaunching). P00=1 : fan and compressor stopped P00=2 : fan and compressor stopped, boiler operating if required, as per selected mode (whatever P40) Level 2 : On MRS5 fault display, flashing red LED, and closing of J5. In case of fault, there is a neutral available on the terminal box J5, terminal 5 for recovering the unit fault or non fault information. When the unit is in level 1 fault in heating mode only, it is possible to put back into operation the auxiliary electrical devices for 48 hrs (while waiting for the fault repair) : through the Climbox 2 (P04 = 0) by pressing 10 sec. On the Run / Stop key through the all or nothing entries (P04 = 1) by closing the contact J2 11 12 through the MCAD5 (P04 = 2) by pressing key Reset Level or 0 : Automatic acquittal as soon as fault disappears. Level 1 or 2 : Acquittal as soon as fault dispappears and resetting of the card (reset). Trefoulement > P14 plus de 5 fois en 24h en mode chaud ou hors-gel btiment Discharge T > P14 more than 5 times within 24 hrs in heating mode or building frost free mode Trefoulement > P17 plus de 5 fois en 24h en mode froid Discharge T > P17 more than 5 times within 24 hrs in cooling mode Ouverture du contact du pressostat diffrentiel durant moins de 6mn Opening of the differential pressostat contact for at least 6 mn. Ouverture du contact du pressostat diffrentiel durant plus de 6mn Opening of the differential pressostat contact for more than 6 mn Tretour d'eau < P10 en mode chaud et hors-gel btiment (acquittement possible si Tretour d'eau >P10+2) Water return T < P10 in heating and building frost free mode (Acquittal possible if water rerurn T>P10+2) Tretour d'eau < P10 en mode froid (acquittement possible si Tretour d'eau >P10+2) Water return T < P10 in cooling mode (Acquittal possible if water rerurn T>P10+2) Tch-fron = 2C pour P00=0, 17C pour P00=1 durant moins de 7mn en mode froid Refrigerant fluid exchange T = 2C for P00 = 0, 17C for P00 = 1 for at least 7 mn in cooling mode Tch-fron = 2C pour P00=0 ou 2, 17C pour P00=1 durant 1mn en mode chaud / hors-gel ou Tch-fron = 10C pour P00=0 ou 2, 25C pour P00=1 en mode chaud / hors-gel Refrigerant fluid exchanger = 2C for P00=0 or 2, 17C for P00=1 for 1 mn in heating/frost free mode or refrigerant fluid exchanger T = 10C for P00 = 0 or 2, 25C for P00 = 1 in heating/frost free mode Tch-fron = 2C pour P00=0, 17C pour P00=1 durant plus de 7mn en mode froid Refrigerant fluid exchanger T = 2C for P00 = 0, 17C for P00 = 1 for more than 7 mn in cooling mode Coupure BP depuis moins de 15mn LP cut for less than 15 mn 5 coupures BP en 24h en mode chaud / hors-gel btiment 5 LP cuts within 24 hrs in heating/building frost free mode 5 coupures BP en 24h en mode froid 5 LP cuts within 24 hrs in cooling mode Coupure HP depuis moins de 5mn en chaud / hors-gel btiment, moins de 30mn en froid HP cut for less than 5mn in heating/building frost free, less than 30 mn in cooling 5 coupures HP en 24h en chaud / hors-gel btiment 5 HP cuts within 24 hrs in heating/building frost free mode 5 coupures HP en 24h en mode froid 5 HP cuts within 24 hrs in cooling mode Origine du dfaut Origin of fault 3 fois Trefoulement > P13 en moins de 50mn durant la phase du compteur givrage 3 times discharge T> P13 in less than 50 mn during the frosting counter phase 5 dfauts d7. 1 that was switched from the heating/building frost-free mode to cooling or stop Coupure du thermostat 78C sur les thermoplongeurs, ou du thermostat PCR 63C, ou les relais des sorties J6-2, J6-4 et J6-6 de la carte MRS5 sont bloqus en position ouverte Cutting of thermostat at 78C on the immersion heaters or of PCR thermostat at 63C, the MRS5 card exit relays J6-2, J6-4 and J6-6 are blocked in the open position Coupure ou court-circuit fil sonde fron batterie en mode chaud / hors-gel btiment Cutting or short-circuiting of coil refrigerant fluid sensor wire in heating / building frost free mode Coupure ou court-circuit fil sonde fron batterie en mode froid Cutting or short circuiting of coil refrigerant fluid sensor wire in cooling mode Groupe en d9. Which was diverted into heating / building frost free mode Coupure ou court-circuit fil sonde fron changeur en mode froid Cutting or short circuiting of exchanger refrigerant fluid sensor wire in cooling mode Coupure ou court-circuit fil sonde extrieur en mode chaud / hors-gel btiment Cutting or short circuiting of the outside sensor wire in in heating /building frost free mode Coupure ou court-circuit fil sonde extrieur en mode froid Cutting or short-circuiting of the outside sensor wire in cooling mode Coupure ou court-circuit fil sonde refoulement en mode chaud / hors-gel btiment Cutting or short-circuiting of discharge sensor wire in heating / building frost free mode Coupure ou court-circuit fil sonde refoulement en mode froid Cutting or short-circuiting of discharge sensor wire in cooling mode Coupure ou court-circuit fil sonde sur retour d'eau changeur plaques Cutting or short-circuiting of sensor wire on plate exchanger water return Sonde de refoulement compresseur com resseur Compressor discharge sensor Sonde sur retour eau changeur plaques Sensor or plate exchanger water return Sonde sur dpart eau changeur plaques Sensor or plate exchanger water departure Sonde botier d'ambiance (uniquement si P07=1) Ambient box sensor (only if P07 = 1) Potentiomtre botier d'ambiance (uniquement si P07=1) Ambient box potentiometer (only if P07 = 1) Mmoire Eeprom Eeprom memory Liaison Programmateur (uniquement si P04=0) Programmer liaison (only if P04 = 0) Liaison CAD (uniquement si P04=2) Remote control liaison (only if P04 = 2) Chaudire (uniquement si P00=2) Boiler (only if P00 = 2) Tretour d'eau = P05 en dgivrage pour P00=1 our Return water T = P05 in defrosting for P00 = 1 Coupure fil potentiomtre botier d'ambiance Ambient box potentiometer wire cut Dfaut Eeprom carte (prvoir le remplacement de la carte) Eeprom card fault Absence de communication sur le fil pilote durant plus de 48h No communication on the pilot wire for more than 48 hrs Ouverture entre chaudire (sur la carte MRS5, entre J2-5 et J2-6) Boiler entry opening (on the MRS 5, between J2. 6) Tretour d'eau = P05 avant de lancer le dgivrage sur un ILZC sans appoint (P00=1) Return water T = P05 before launching the defrosting on a ILZC without auxiliary unit (P00 = 1) Groupe en d14. In cooling mode : the fan motor assembly operates in speed variation (the speed is function of the condensing temperature models 15 to 65 or function of the pressure on models 90 and 130). In defrosting mode : the fan motor operates only when the condensing pressure is too high (HPD). Furthermore, in order to avoid the risk of HP peaks when the 4-way valve reverses (for units with R407C) it is possible to activate the fan motor by using parameter P11. This safety device is active in all cases D For the ILZHE with R22 and the ILZC with R22/R407C, the heater is controlled by the MRS5. 1B P00 = 0 and P01 = 0 , P002 : If external air T < 2C and if (water return T < 3C or water outlet T < 3C) , heater is supplied. Heater stops as soon as external air T > 4C or (water return T > 5C and water outlet T > 5C). P00 = 1 : If external air T < 13C and if (water return T < 12C or water outlet T < 12C), then the heater is supplied. The heater stops as soon as the external air T > 11C or (water return T > 10C and water outlet T > 10C). D For the ILZHE with R407C (P00 + 0 and P01 = 1) ; the heaters are not controlled by the card as the outlet controls the bypass valve. Water temperature in the water loop whatever the operating mode (cooling - heating - building frost-free mode and stop). In case of outside sensor fault, the hydraulic safety goes automatically into the scanning phase. [. . . ] To cancel this mode, press a second time on key "TEST", otherwise the mode cancels itself after a 1 hour period. The green light of the card illuminates : In the case where the factory setting of parameters is not satisfactory, it is possible to modify them . Point de mesure prvu sur la carte Measurement point planned on the card Le groupe ne fonctionne pas et il n'y a pas d'affichage sur la carte CPU The unit does not operate and there is no display on the CPU card D The fuse of the card is out of order (F1). Type of fuse => 5 x 20 1A delayed D The card is not supplied with electricity or the voltage is too low, check the presence of 230V between J4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CIAT MICROCIAT MRS 5-1 B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CIAT MICROCIAT MRS 5-1 B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.