User manual CISSELL CF 24

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL CF 24. We hope that this CISSELL CF 24 user guide will be useful to you.


CISSELL CF 24 : Download the complete user guide (705 Ko)

Manual abstract: user guide CISSELL CF 24

Detailed instructions for use are in the User's Guide.

[. . . ] Do not touch any electrical switch; do not use any phone in your building. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: In the event the user smells gas odor, instructions on what to do must be posted in a prominent location. WARNING: Purchaser must post the following notice in a prominent location: FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING: A clothes dryer produces combustible lint and should be exhausted outside the building. [. . . ] Lors des opérations dentretien des commandes, ètiqueter tous les fils avant de les dèconnecter. Toute erreur de câblage peut être une source de danger et de panne» Page 13 Gas Piping Installation GAS PIPING INSTALLATION 1. The installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI Z223. 1 or the CAN/CGA-B149, Installation Codes. Check with utilities company for proper gas pressure and gas supply line. Natural gas onlycheck the gas pressure inlet supply to dryer, 10. 5 inches water column (26. 2 mbar) maximum. gas onlycheck the gas pressure inlet supply to dryer, 13 inches water column (32. 4 mbar) maximun. A minimum 1/8 - inch NPT plugged tapping, accessible for tests gage connection, must be installed immediately upstream of the gas supply connection to the dryer. CAUTION: Low gas pressure and intermittent gas will cause gas ignition problems and inadequate drying of laundry. Page 14 Gas Piping Installation (Illustration) Gas Valve Gas Supply The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3. 5 kPa). The dryer must be isolated from the gas supply piping system by closing it's individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3. 5 kPa). Page 15 Gas Service Installation Instructions GAS SERVICE INSTALLATION INSTRUCTIONS The size of the gas service pipe is dependant upon many variables, such as tees, lengths, etc. Refer to the Gas Pipe Size chart in this manual for general gas pipe size information. CAUTION: Gas loop piping must be installed as illustrated to maintain equal gas pressure for all dryers connected to a single gas service Other gas-using appliances should be connected upstream from the loop. WARNING: LIQUIFIED PETROLEUM GASES ONLY ! GAS PRESSURE REGULATOR FOR LIQUIFIED PETROLEUM GASES A gas pressure regulator for liquified petroleum gases is not furnished on the gas heated clothes dryers. In accordance with American Gas Association (AGA) and Canadian Gas Association (CGA) standards, a gas pressure regulator, when installed indoors, must be equipped with a vent limiter or a vent line must be installed from the gas pressure regulator vent to the outdoors. Page 16 Gas Pipe Size Chart TOTAL BTU/HR (for LP Gas correct total BTU/HR below by multiplying by . 6) TOTAL KCAL HOUR (25 ft. ) 7, 62 m 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 2 2 2 2 2 2 2 2 2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 2 1/2 3 3 3 3 3 GAS PIPE SIZE FOR 1000 BTU (250 KCAL) NATURAL GAS AT 7 W. C. (17. 5 MBAR) PRESSURE In figuring total length of pipe, make allowance for tees and elbows. Exhaust duct maximum length 14 feet (5 m) of straight duct and maximum of two 90° bends. Use 2 feet (0. 6 m) of straight duct on dryer before installing an elbow on energy-saver models only. Use clean-outs in the exhaust duct and clean periodically when needed. Examine the exhaust system at least once every three months, and more frequently if indicated. Never exceed 0. 3 inches water column (. 75 mbar) static pressure in the exhaust duct. Provide opening to the out-of-doors in accordance with the following: For each dryer 6 inches (153 mm) diameter exhaust requires a 1 square feet (0. 1 m²) opening for make-up air. 8 inches (204 mm) diameter exhaust requires a 2 square feet (0. 2 m2) opening for make-up air. 12 inches (305 mm) diameter exhaust requires a 4 square feet (0. 4 m2) opening for make-up air. Use barometric shutters in the inlet air opening to control air when dryers are not running. Other Recommendations To assure compliance, consult local building code requirements. Troubleshooting Hot dryer surfaces, scorched clothes, slow drying, lint accumulations, or air switch malfunction are indicators of exhaust duct and/or make-up air problems. EXHAUST DUCT MAKE-UP AIR OTHER RECOMMENDATIONS TROUBLESHOOTING Page 21 Rules for Safe Operation of Dryer RULES FOR SAFE OPERATION OF DRYER 1. [. . . ] Switch must close before air blade engages face of opening and re-open before stop F engages. TUD0528 TUD0283 TUD0375 TU7733 TUD0258 EA-00650-0 TUD0241 TUD0239 TUD0240 TUD0134 TUD0282 Description JACKET WELDED ASSY INSULATION, TOP COIN CHUTE SCREW SELF TAP SPRING RETAINER SWITCH, LINT DRAWER SWEEP SHEET LR SWEEP SHEET UR SWEEP SHEET LL SWEEP SHEET UL INSULATION SIDE Page 35 FRONT PANEL ASSEMBLY (See next page) Page 36 FRONT PANEL ASSEMBLY (See previous page) * TUD0480WH - Front panel assembly complete -Upper * TUD0481WH - Front panel assembly complete - Lower coin * TUD0482WH - Front panel assembly complete - Lower opl Ref. Description 1 * 2 3 4 5 6 7 8 9 10 11 12 SB-00915-0 TUD0476WH TUD0477WH TU3213 TU2876 TU14992 TU7733 SB-00852-0 CA-00699-0 ESA-00862-0 SB-00975-0 TUD0475WH SB-00836-0 Screw, #10-16 self drilling Front panel - Lower coin Front panel - Lower opl Pop rivet Door catch Insulation ( 3 pcs) Screw #8 Self tapping Washer star Coin box bezel (some models) Reed switch Screw #6-32 Front panel - Upper Screw #10 pancake * * Please specify color Page 37 DOOR ASSEMBLY Ref. TU15110 1 2 3 4 5 6 7 8 9 10 CA-13218 TU15536 MD-00360-0 SB-00852-0 SB-00921-0 TU15073 TU15076 TU15107 TU15108 TU4840 Description Complete door assy (Indicate color) Catch pin Magnet - read switch Gasket - door rim gasket Washer 1/4" external starluck Screw 1/4"-20 round head Door hinge spacer Door rim w/a Door glass Door glass gasket #10-32 Crown nut Page 38 CONTROL PANEL PARTS - TUMBLER ASSEMBLY Ref. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL CF 24




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL CF 24 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.