User manual DRAKE DIGITAL MEQ1000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DRAKE DIGITAL MEQ1000. We hope that this DRAKE DIGITAL MEQ1000 user guide will be useful to you.


DRAKE DIGITAL MEQ1000 : Download the complete user guide (368 Ko)

Manual abstract: user guide DRAKE DIGITAL MEQ1000

Detailed instructions for use are in the User's Guide.

[. . . ] MEQ1000 Hybrid QAM Modulator DTD1000 Digital Tuner and Demodulator Module SDE24 Encoder module ASII ASI Input Module Instruction Manual MEQ1000 Multiplexing Edge QAM Modulator QAM OUTPUT 0. 000 Mbits/S ENTER SELECT TM is a trademark of R. L. Drake LLC P/N: 3852511_D-03-2010 Printed in U. S. A. 2 Caution Statements WARNING: TO PREVENT FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE TO RAIN OR MOISTURE A product and cart combination should be moved with care. Quick stops, excessive force and uneven surfaces may cause the product and cart combination to overturn. The lightning flash with arrow head symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. [. . . ] R6, RS232 in - Connection to a PC or modem for use with remote control / monitoring program or for firmload download. R8, AC Line Cord ­ For connection to the nominal 120 VAC power source. This unit is designed for use in Setup and Programming / Software Flow Chart Programming and viewing of the various setup and operating parameters is accomplished using the front panel back lit, two line, sixteen character wide LCD along with the two LEFT and RIGHT SELECT buttons and the five LEFT, RIGHT, UP, DOWN and ENTER buttons. The name of the parameter is on the top line of the display and the setting value is on the bottom line. To observe a certain parameter setting without intending to change its value, just use the LEFT and RIGHT SELECT buttons and the LEFT and RIGHT arrow buttons to navigate through the menus shown in the software flow chart below. The current setting for each parameter is shown on the bottom line of the display. Note that depending upon certain settings, some screens are not needed and will be skipped. 9 To make a change in the displayed parameter and its setting and if this is the initial setup, you will want to enter the `adjust' mode. To do this, press the ENTER button that is located in the center of the four arrow buttons and hold in for several seconds until the display begins to flash. After you are in the adjust mode (bottom line of screen flashing) use the left and right arrows to navigate among screens and use the up and down arrows to change the parameter setting. When ENTER is pressed, the new settings will be loaded and stored and the unit will exit the `adjust' mode. You may wish to not press ENTER until you have gone through all screens and settings and then press ENTER to save and load all changes in one step OR you can store just one or several parameters at a time and reenter adjust mode to set the next. Either method is acceptable. SELECT ENTER NORMAL MODE RS-232 BAUDRATE UNIT ID SETUP: MEQ1000 RF LEVEL MULTIPLEX INPUT B OFFSET MPEG PROGRAMS PSIP VCT TABLE MAJOR CHANNEL QAM MODE (These screens only appear if MULTIPLEX is ENABLED. ) OUTPUT CHANNEL QAM SYMRATE Mbits/S QAM SYMRATE PRESET GRAY ENCODING (This screen appears only if ITU-A is selected. ) OUTPUT CHANMAP OUTPUT FORMAT INTERLEAVER ADJUST MODE UNIT ID Select 0 - 63 RS232 BAUDRATE 2400 4800 9600 19200 MULTIPLEX USE A INPUT ONLY USE B INPUT ONLY ENABLED INPUT B OFFSET 0 - 90 MPEG PROGRAMS SELECT ALL PROGS SELECT PROGRAMS PSIP ENABLED BASIC MGT/VCT DISABLED VCT TABLE TVCT CVCT MAJOR CHANNEL ORIGINAL CHANNEL OUTPUT CHANNEL USER DEFINED QAM MODE ITU-A QAM-16A QAM-32A QAM-64A QAM-128A QAM-256A QAM-512A QAM-1024A GRAY ENCODING DAVIC DVB (This screen appears only if ITU-A is selected. ) ITU-B QAM-64B QAM-256B QAM-1024B (These screens only appear if MULTIPLEX is ENABLED. ) RF LEVEL 45 - 62 dBmV OUTPUT CHANNEL 1 - 158 OUTPUT CHANMAP BROADCAST CATV IRC HRC OUTPUT FORMAT NORMAL PRBS15 PRBS15M PRBS23 PRBS 23M CW INTERLEAVER (This screen appears only if ITU-B is selected. ) QAM SYMRATE 1. 000 7. 000 QAM SYMRATE PRESET MANUAL I128, J1 I128, J2 I64, J2 I128, J3 I132, J4 I128, J4 I16, J8 I128, J5 I8, J16 I128, J6 I4, J32 I128, J7 I2, J64 I128, J8 I1, J128 NORMAL MODE SETUP INPUT A: DTD1000 DTD1000 Lock Status Tuner AGC Demodulator ADJUST MODE DTD1000 MODE: VSB-8 QAM-64B QAM-256B NORMAL MODE DTD1000 CHANMAP DTD1000 CHANNEL DTD1000 MODE DTD1000 CHANMAP: BROADCAST CATV IRC HRC DTD1000 CHANNEL: 1 - 158 This chart assumes a DTD1000 module or a SDE24 module in Input - A and an ASII module is in Input - B. This could be different. SETUP INPUT A: SDE24 VIDEO FORMAT BITRATE: RESOLUTION BRIGHTNESS CONTRAST SATURATION AUDIO ENCODE:Exx AUDIO GAIN MAX AUDIO IN HUE PROGRAM MODE VIDEO S-VIDEO COMPOSITE FORMAT MPEG2 MPEG4 H. 264 (This screen only appears for Encoder 1 in a given SDE24 module. Encoder 2 in that module is always forced to MPEG2. ) BITRATE: 1 - 8 Mbits/S RESOLUTION 720 704 528 480 352 353 x x x x x x 480 480 480 480 480 240 BRIGHTNESS 0 - 255 CONTRAST 0 - 255 SATURATION 0 - 255 AUDIO ENCODE:Exx AC3 MP2 AUDIO GAIN MUTE + 15 dB to -15 dB in 1 dB steps MAX AUDIO IN 1 Vrms 2 Vrms HUE 0 - 255 SETUP INPUT B: ASII MODULE Indicates that ASII module is installed. ASII module has no adjustments. 10 Setup and Programming, continued Choose the SELECT PROGRAMS setting to allow the operator to pick which programs from the A and B inputs are to be included in the output multiplex. NOTE: At this point you may proceed through the remaining menus, below, before pressing the ENTER button to load the selected data OR you may press ENTER now and then come back to the rest of the menus. In any case, when the ENTER button is pressed, one of the following two actions will occur: A) If SELECT ALL PROGS has been selected, the MEQ1000 will now read PAT tables from the two input streams and discover which MPEG programs are defined. If you wish to view the MPEG program numbers of programs that were found, follow the procedure below: VIEWING MPEG PROGRAM NUMBERS In order to see the MPEG program numbers of incoming streams, the following procedure can be followed: 1) Press the ENTER button for 2 seconds to enter program mode. By continuing to hold in the ENTER button, the following display will be slowed down so that program numbers can be read as they scroll by. 3) A screen will be displayed that indicates: PMT PROG A xxxx or PMT PROG B xxxx. 4) The xxxx field will be a number that corresponds to the MPEG program number of a program found in the PMT table for the indicated (A or B) input. As the button is held, all entries for input A will scroll past and then entries for input B will scroll past. [. . . ] The unit must be sent to the following address: Service Department R. L. Be sure to include your street address which will be needed for UPS return. UPS Surface (Brown Label) takes 7-10 days to reach us depending on your location, Blue takes 2-3 days. Red is an overnight service. Send the unit in a way that it can be traced if we can't verify receipt of shipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DRAKE DIGITAL MEQ1000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DRAKE DIGITAL MEQ1000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.