User manual DSC PC 1555

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC PC 1555. We hope that this DSC PC 1555 user guide will be useful to you.


DSC PC 1555 : Download the complete user guide (640 Ko)

Manual abstract: user guide DSC PC 1555

Detailed instructions for use are in the User's Guide.

[. . . ] About Your Security System Your DSC security equipment has been designed to provide you with the greatest possible flexibility and convenience. Read this manual carefully and have your installer instruct you on your system's operation and on which features have been implemented in your system. Fill out the "System Information" page with all of you zone information and access codes and store this manual in a safe place for future reference. Fire Detection This equipment is capable of monitoring fire detection devices such as smoke detectors and providing a warning if a fire condition is detected. Good fire detection depends on having adequate number of detectors placed in appropriate locations. [. . . ] 11 Setting the System Date and Time To set the system time, enter [D] [6] followed by the Master Code. The keypad will now accept 10 consecutive digits: · Enter the Time in Hours and Minutes using the 24 Hour format (00:00 to 23:59). NOTE: If you have an LCD keypad, your installer may have programmed your system to display the time and date while the keypad is idle. If this is the case, you may have to press the [#] key to clear the date and time before entering an access code to arm the system, or before performing any other keypad function. Testing Your System Alarm Test The Alarm Test provides two second test of the keypad sounder and bell or siren. From an LED keypad, Enter [D][6][Master Code][4] then press [#] to return to the Ready state. Use the arrow (< >) keys to scroll to find "User Functions" and press [D] to select. Enter your Master Code and scroll to find the following message. . . Select Option <> Press [D] to perform an Alarm Test. System Test System Test In Progress Press [#] to return to the Ready state. Full System Test We recommend that you test your system weekly. Should the system fail to function properly, call your installation company immediately for service. NOTE: Perform system tests during off-peak hours, such as early morning or late evening. The bell and keypad buzzer will sound for two seconds and all keypad lights will turn ON. From an LED keypad, observe the zone light turn ON when the zone is activated. From an LCD keypad, the following message will be displayed when each zone is activated. . . This message will Secure System Before Arming <> disappear when the zone is restored. If the panel has any fire zones, activation will cause the alarm signal to sound in a pulsed mode. CAUTION: Do not use an open flame or burning materials to test a smoke or heat detector. Contact your installer for information on safe methods of testing detectors. NOTE: Some features described above will not be functional unless enabled by your installer. Please ensure that your installer has advised you which features are functional on your system. 12 Door Chime Feature The door chime feature is used to provide a tone from the keypad each time a door or window is opened or closed. The doors and windows which will provide this indication are programmed by your installer. To activate the door chime from an LED Keypad: Enter [D][4] to turn the door chime feature ON and OFF. When the command is entered, the keypad buzzer will beep 3 times if the door chime feature is enabled and will sound one long beep if it is disabled. To activate the door chime from an LCD Keypad: Press [D] to enter the function list, then scroll to find. . . Press (*) For<> Press [D] or [4] to enable or disable the Door Chime feature. [. . . ] This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC 1555




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC 1555 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.