User manual DSC PC-1832 REV2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC PC-1832. We hope that this DSC PC-1832 user guide will be useful to you.


DSC PC-1832 REV2: Download the complete user guide (1732 Ko)

Manual abstract: user guide DSC PC-1832REV2

Detailed instructions for use are in the User's Guide.

[. . . ] WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. PC1616/PC1832/PC1864 User Manual Table of Contents PowerSeries System Keypads . 20 ii FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. [. . . ] Partition Assignment Mask ([, ][5][Master/Supervisor Code][8][Code]) 1. There will still be 37 codes if option selected for 6-digit access codes. - [, ][5][MASTER CODE] [01 to 32, 33, 34, 40, 41, 42] to program access codes - [, ][5][MASTER CODE][8] enters the Partition Assignment Mode [01 to 32, 33, 34, 41, 42] to edit access code partition assignments - [, ][5][MASTER CODE][9] Enters the Attribute Mode [01 to 32, 33, 34, 41, 42] to edit access code Attributes. When a new code is programmed in it will be checked against all other codes in the system. If a duplicate code is found, an error tone is given and the code is returned to what it was before it was changed. This applies to both 4 and 6-digit codes. Erasing an Access Code To erase a code, select the code and enter as the first digit. is entered, the system will delete the code User Function Commands First disarm the system then enter The [Master Code] command is used to gain access to the following list of Master functions of the system. [1] Time and Date Enter 4 digits for 24 Hour System Time (HH-MM). Enter 6 digits for the Month, Day and Year (MM-DD-YY) 13 [2] Auto-arm Control Pressing [2] while in the User Function menu will enable (3 beeps) or disable (one long beep) the Auto-arm feature, by partition. With this feature enabled, the panel will automatically arm in the Away mode (Stay Away zones active) at the same time each day. The auto-arm time is programmed with the [, ][6][Master Code][3] command. [3] Auto-arm Time The system can be programmed to arm at a programmed time each day, per partition. Upon entry of this section, enter 4 digits for the 24-hour Auto-arm time for each day of the week. At the selected auto-arm time, the keypad buzzers will sound for a programmed amount of time (programmable by the installer only) to warn that an auto-arm is in progress. The bell can also be programmed to squawk once every 10 seconds during this warning period. When the warning period is complete, the system will arm with no exit delay and in the Away Mode. Auto-arming can be cancelled or postponed by entering a valid access code only, during the programmed warning period. When the auto-arming process is cancelled or postponed, the Auto-arm Cancellation Reporting Code will be transmitted (if programmed). If arming is inhibited by one of the following, the Auto-arm Cancellation transmission will be communicated. - AC / DC Inhibit Arm - Latching System Tampers - Zone Expander Supervisory Fault [4] System Test The system's Bell Output (2s), Keypad Lights and Communicator are tested. [5] Enable DLS / Allow System Service If enabled, the installer will be able to access Installer Programming by DLS. In case of DLS access this provides a window where rings will be detected by the panel. The DLS window will remain open for 6hrs, during which time the installer will be able to enter DLS an unlimited number of times. [. . . ] Every installation should be evaluated by a security professional to ensure that all access points and areas are covered. Locks and latches on windows and doors must be secure and operate as intended. Windows, doors, walls, ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected. A reevaluation must be done during and after any construction activity. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC-1832




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC-1832 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.