User manual FRIGIDAIRE FAC104P1AB

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FRIGIDAIRE FAC104P1AB. We hope that this FRIGIDAIRE FAC104P1AB user guide will be useful to you.


FRIGIDAIRE FAC104P1AB : Download the complete user guide (814 Ko)

You may also download the following manuals related to this product:

   FRIGIDAIRE FAC104P1AB (889 ko)
   FRIGIDAIRE FAC104P1AB (848 ko)

Manual abstract: user guide FRIGIDAIRE FAC104P1AB

Detailed instructions for use are in the User's Guide.

[. . . ] · Cooktop cutout height includes clearance needed beneath cooktop to allow for armored cable and installation of junction box on back wall. Position center of junction box 10" inward from right side of cooktop cutout, and 12" down from underside of countertop. · Overhead cabinetry should not exceed a 13" maximum depth. [. . . ] · Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than 30-3/4". · Allow 30" minimum clearance between top of cooktop platform and bottom of unprotected wood or metal overhead cabinet; or 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MSG sheet steel, 0. 015" stainless steel, 0. 024" aluminum or 0. 020" copper. · Allow 1-1/2" minimum clearance between rear edge of cutout and nearest combustible surface (or backsplash) above countertop. to nearest combustible wall and 7-1/2" minimum from right edge of cooktop to nearest combustible wall. · To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets. · Electric Built-In Cooktop model FPIC3095M is approved to be used over any Frigidaire® Electric Single Wall Oven. (Refer to Electric Cooktop Installation Over 30"/27" Electric Single Wall Oven Specifications page on web. ) · Electric Built-In Cooktop model FPIC3095M is approved to be used in combination with Frigidaire® 30" Downdraft Vent E30DD75ESS or PL30DD50EC. For detailed Electric Cooktop installation, refer to model-specific product page and installation guide on web. · Side filler panel height may need to be modified to accommodate the depth of approved electric cooktop models. · To route armored cable to junction box, cut minimum 4" x 4" opening in right side filler panel. · Allow 4-1/2" maximum height from oven base to floor, if cooktop is installed directly over wall oven. Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire. com for detailed instructions. AC only electrical supply with ground required on separate circuit fused on both sides of line. · For detailed electrical requirements, refer to model-specific product page and installation guide on web. · Minimum 27-1/4" clearance for oven door depth when open. [. . . ] · For detailed electrical requirements, refer to model-specific product page and installation guide on web. · Minimum 27-1/4" clearance for oven door depth when open. · Minimum 23-1/2" deep cutout dimension is critical for proper installation, to ensure that oven's faceplate will fit flush against cabinet front. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FRIGIDAIRE FAC104P1AB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FRIGIDAIRE FAC104P1AB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.