User manual FRIGIDAIRE FGMO205K B DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FRIGIDAIRE FGMO205K B. We hope that this FRIGIDAIRE FGMO205K B user guide will be useful to you.


FRIGIDAIRE FGMO205K B DATASHEET: Download the complete user guide (975 Ko)

Manual abstract: user guide FRIGIDAIRE FGMO205K BDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] · Grounded outlet should NOT be located in shaded area, as indicated, UNLESS cabinet depth is greater than 21". (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation. ) · Amps @ 120 Volts = 14. 3 Amps · Always consult local and national electric codes. · Microwave can stand alone on countertop or be built in with optional 30" or 27" Trim Kit (ordered by individual part number) which includes Bottom Duct Assembly ­ shipped in separate box. [. . . ] · To adapt oven to fit cutout height greater than 28-1/8", add one 2"-wide wood shim of appropriate height to each side of opening under oven side rails. Lifting oven will hide larger cutout opening at top and oven's 1"-high bottom trim will hide shims at bottom. (Standard 1"- High Bottom Trim included. ) · To adapt oven to fit cutout height greater than 28-5/8", optional 3"- High Bottom Trim available. Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire. com for detailed instructions. 30" Trim Kit which includes Bottom Duct Assembly ­ shipped in separate box, ordered by individual part number. · Voltage Rating ­ 120V/60 Hz/15 or 20 Amps · Connected Load (kW Rating) @ 120 Volts = 1. 7 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation. ) · Amps @ 120 Volts = 14. 3 Amps · Full oven base of solid plywood or similar material required, capable of supporting 100 Lbs. · Minimum 2-7/8" clearance required from bottom of Built-In Microwave cutout to top edge of Wall Oven's faceplate, leaving a 2" visible gap between both product faceplates. FRIGIDAIRE® USA · 250 Bobby Jones Expressway · Martinez, GA 30907 · 1-800-FRIGIDAIRE · frigidaire. com CANADA · 5855 Terry Fox Way · Mississauga, ON L5V 3E4 · 1-800-265-8352 · frigidaire. ca MOSS_EW 30INST FR 09/09 © 2009 Electrolux Home Products, Inc. Specifications subject to change. Printed in the U. S. A. 27"Combination Installation Built-In Microwave/Single Wall Oven 27" Combination Installation Specifications · Always consult local and national electric codes. 27" Electric Single Wall Oven Specifications · Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz (Refer to product-specific electrical specifications on this page. ) · Minimum 23-1/2" deep cutout dimension is critical for proper combination installation, to ensure that each built-in product's faceplate will fit flush against cabinet front. · Minimum 4-1/2" required distance from bottom of Wall Oven cutout to floor, 31" suggested. · Respect critical dimensions as noted for proper installation of built-In products. · Minimum 21" clearance needed for Wall Oven door depth when open. AC only electrical supply with ground required on separate circuit fused on both sides of line. · For detailed electrical requirements, refer to model-specific product page and installation guide on web. · Full base of solid plywood or similar material required, capable of supporting 200 Lbs. · To adapt oven to fit cutout height greater than 28-1/8", add one 2"-wide wood shim of appropriate height to each side of opening under oven side rails. Lifting oven will hide larger cutout opening at top and oven's 1"-high bottom trim will hide shims at bottom. (Standard 1"- High Bottom Trim included. ) Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire. com for detailed instructions. 27" Built-In Microwave Specifications · For built-in installation, microwave MUST be installed with optional 27" Trim Kit which includes Bottom Duct Assembly ­ shipped in separate box, ordered by individual part number. · Voltage Rating ­ 120V/60 Hz/15 or 20 Amps · Connected Load (kW Rating) @ 120 Volts = 1. 7 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation. ) · Amps @ 120 Volts = 14. 3 Amps · Full oven base of solid plywood or similar material required, capable of supporting 100 Lbs. [. . . ] · Minimum 2-7/8" clearance required from bottom of Built-In Microwave cutout to top edge of Wall Oven's faceplate, leaving a 2" visible gap between both product faceplates. FRIGIDAIRE® USA · 250 Bobby Jones Expressway · Martinez, GA 30907 · 1-800-FRIGIDAIRE · frigidaire. com CANADA · 5855 Terry Fox Way · Mississauga, ON L5V 3E4 · 1-800-265-8352 · frigidaire. ca MOSS_EW_WD 30INST FR 09/09 © 2009 Electrolux Home Products, Inc. Specifications subject to change. Printed in the U. S. A. 27"Combination Installation Built-In Microwave/Single Wall Oven/Warmer Drawer 27" Combination Installation Specifications · Always consult local and national electric codes. 27" Electric Single Wall Oven Specifications · Single phase 3- or 4-wire cable, 120/240 or 120/208 Volt, 60 Hertz (Refer to product-specific electrical specifications on this page. ) · Minimum 23-5/8" deep cutout dimension is critical for proper combination installation, to ensure that each built-in product's faceplate will fit flush against cabinet front. · Minimum 4-1/2" required distance from bottom of Warmer Drawer cutout to floor. · Respect critical dimensions as noted for proper installation of built-In products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FRIGIDAIRE FGMO205K B




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FRIGIDAIRE FGMO205K B will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.