User manual FRIGIDAIRE GLMV169 Installation Instruction

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FRIGIDAIRE GLMV169. We hope that this FRIGIDAIRE GLMV169 user guide will be useful to you.


FRIGIDAIRE GLMV169 Installation Instruction: Download the complete user guide (539 Ko)

Manual abstract: user guide FRIGIDAIRE GLMV169Installation Instruction

Detailed instructions for use are in the User's Guide.

[. . . ] Use a stud finder, a magnetic device which locates the nails in the stud. Use a hammer to tap lightly across the mounting surface to find a solid sound. The center of the stud can be located by probing the wall with a small nail to find the edges of the stud and then placing a mark halfway between the edges. The center of any adjacent studs will normally be 16" or 24" to either side of this mark. 66" or more from floor NEED HELP? For customers in the United States, call: 1-800-944-9044 For customers in Canada, call: 1-800-213-9397 (English) 1-800-668-4606 ext. 8199 (French) Figure 1 READ CAREFULLY. [. . . ] present additional resistance to air flow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total length, add the equivalent lengths of all transitions and adapters plus the length of all straight duct sections. Figure 3 shows the approximate feet of equivalent length of some typical ductwork parts. Use the values in parentheses for calculating air flow resistance equivalent, which should total less than 140 feet. Ground Receptacle Opening for Power Cord Figure 3 Figure 2 2 Installation Instructions 5 TOOLS RECOMMENDED FOR INSTALLATION · · · · · · · · · · Phillips Screwdriver Electric Drill 1/2", 5/8" and 3/32" Drill Bits 1-1/2" Wood Bit or Metal Hole Cutter (if metal cabinet is used) Saw to cut exhaust opening (if needed) Protective Drop Cloth for product and range you may also use carton for protection Scissors Pencil Measure Tape 7 PREPARATION OF THE OVEN 1. Open the bottom of the carton, bend the carton flaps back and tilt the oven over to rest on plastic foam pad. Lift carton off oven and remove all packing materials, Installation Instructions, Wall Template, Top Template, Charcoal Filter, Turntable and Turntable Support; however, DO NOT REMOVE THE WAVEGUIDE COVER, which is located on the ceiling in the oven cavity. Check the oven for any damage, such as misaligned or bent door, damaged door seals and sealing surfaces, broken or loose door hinges and latches and dents inside the cavity or on the door. If there is any damage, do not operate the oven and contact your dealer or ELECTROLUX AUTHORIZED SERVICER. Pull the louver away from the unit and set aside. 6 INSTALLATION HARDWARE The INSTALLATION HARDWARE (items 1 - 8) packed with the oven should contain the following: Item 1 2 3 4 5 6 7 8 9 Name Wood Screw 5 X 30 mm Toggle Bolt 3/16 inch Top Cabinet Screw 5 X 60 mm Flat Washer 30 mm diameter Power Cord Hanger Grommet Tapping Screw 4 x 12 mm Exhaust Damper Assembly Charcoal Filter Quantity 6 4 2 2 1 1 4 1 1 5. Loosen the two Mounting Screws (D) which secure the Mounting Plate to the rear side of the oven. See Figure 6. (A) Mounting Plate (A) (A) (A) Control Panel Side Figure 5 Mounting Plate (D) (D) Figure 4 Parts shown not to common scale. Figure 6 3 Installation Instructions 8 VENTILATION SYSTEM (PREPARING OVEN FOR INSTALLATION) This Microwave Oven/Hood is designed for adaptation to three types of hood ventilation systems. Recirculating requires the use of the Charcoal Filter, which has been installed in the oven. Replace the Fan Cover Bracket by sliding it into the slits in the same direction as the arrow on the Fan Cover Bracket. Make sure the fan blades are visible through the rear openings in the oven before proceeding. Attach Fan Cover Bracket to unit with 3 screws, which were removed in Step 1 above. Attach the Exhaust Damper Assembly to the back of the Mounting Plate by sliding it into the slits in the same direction as the arrow. Use Tapping Screw 4 X 12 from the INSTALLATION HARDWARE and tighten into place. (A) RECIRCULATING: Non-Vented, Ductless Operation 1. The Exhaust Damper Assembly is not required for recirculating exhaust. Charcoal Filter, included with the unit, is required for recirculating exhaust. Attach the Charcoal Filter to the upper side of the oven by sliding into the tabs. The Charcoal Filter should be replaced every 6 to 12 months, depending on use. Back of Oven Figure 8 Tabs Tabs Figure 9 Figure 7 (B) HORIZONTAL EXHAUST: OUTSIDE VENTILATION 1. [. . . ] Figure 16. Tapping Screw Figure 12 8 VENTILATION SYSTEM (PREPARING OVEN FOR INSTALLATION) cont. (C) VERTICAL EXHAUST: OUTSIDE VENTILATION 1. Remove and save 2 screws from back edge and 1 screw from the top center of the Fan Cover Bracket. Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket as shown in Figure 8. Rotate the Hood Fan Unit 90° so that the fan blade openings are facing upward. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FRIGIDAIRE GLMV169




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FRIGIDAIRE GLMV169 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.