User manual GEORG FISCHER PA30
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GEORG FISCHER PA30. We hope that this GEORG FISCHER PA30 user guide will be useful to you.
Manual abstract: user guide GEORG FISCHER PA30
Detailed instructions for use are in the User's Guide.
[. . . ] 3-way ball valve horizontal with pneumatic actuator Type 201, 202, 203
General
The series 201, 202 and 203 includes three-way ball valves with pneumatic actuator in their horizontal version in PVC-U, PVC-C, ABS, PP and PVDF. [. . . ] to obtain the absolute values, these values must be multiplied by the corresponding Kv 100 values.
L-port ball
Valve adjustments for L-port ball
Standard version
Flow A
B and A
C
Opening angle Kv Kv-value
T-port ball
Valve adjustments for T-port ball
Standard version
Flow C
A and C
B
Flow A
B and A
C
Opening angle Kv Kv-value
Opening angle Kv Kv-value
Kv-value p = 1bar L-port ball
Flow A C, C A, B Valve position: 90° DN mm 10 15 20 25 32 40 50
C, C Kv 100 l/min 50 75 150 280 480 620 1230
B
T-port ball
DN mm 10 15 20 25 32 40 50
Flow A B Valve position: 90° Kv 100 l/min 140 200 470 793 1290 1910 3100
Pressure drop diagram L-port ball standard
Flow C A Valve position: 90°
Y
Medium: Water, 20 °C X Flow rate (l/min) Y Pressure loss p (bar)
T-port ball standard
Flow A B Valve position: 90°
Y
Medium: Water, 20 °C X Flow rate (l/min) Y Pressure loss p (bar)
Design of Actuated valve
Actuator type PA10/PA20
Coupling Intermediate element
Ball valve type 343
Technical data for actuator PA10/PA20
Control medium Control medium temperature Control pressure (recommended values) Fail safe to close (FC) Fail safe to open (FO) Double acting (DA) Neutral, non-aggressive gas (Control by liquid media on request) max. 40 °C
Ball valve breakaway torque (Nm)
Ball valve breakaway torque (Nm)
Max. acceptable control pressure 7 bar Control connection Control time Control angle Functions G 1/4" (Sizing bushes) 15 s, with throttle valve and up to 20 s 90° Fail safe to close (FC) Fail safe to open (FO) Double acting (DA) 10 °C to + 50 °C 0100% optical, integrated PP glass fiber reinforced stainless steel external screws
Acceptable ambient temperature Acceptable air humidity Position indicator Casing material
Control volume
Control volume in dm3 DN mm PA 10 10 15 20 25 32 40 50
1) 2)
single acting (FC/FO) dm3 0. 2
double acting (DA) dm3
1) 2)
0. 15
0. 2
PA 20
0. 25 close open
0. 3
0. 25
Control diagram
Fail safe to close (FC) Double acting (DA)
1 Solenoid valve 3/2-way de-energized closed
1 Solenoid valve 3/2-way de-energized closed T-piece
1 Solenoid valve 3/2-way de-energized closed (or controlled via a 5/2-way-valve) 5/2-way valve diagram A 4 B 2
Fail safe to open (FO)
513 RPS
1 Solenoid valve 3/2-way de-energized closed
Supplementary components/Accessories for PA10/PA20
Name Kit of 2 additional auxiliary switches Kit of 2 additional auxiliary switches inductive, with LED NPN Kit of 2 additional auxiliary switches inductive, with LED PNP Kit of 2 additional auxiliary switches inductive Namur Kit of 2 additional auxiliary switches with gold contacts Kit of 2 additional auxiliary switches EExd II C T 6 Potentiometer kit Technical data 250 V~, 10 A 9, 6-55 V= 0. 2 A 9, 6-55 V= 0. 2 A 5-24 V= 10 mA 430 V= 1100 mA 250 V~, 5 A 1 k/2W Code 199 190 131 199 190 136 199 190 137 199 190 133 199 190 134 199 190 135 199 190 140
Pilot control solenoid valve Type PV 93
Functions: de-energized closed
Version for direct mounting (including base plate and hollow bolt)
200/230 V, 5060 Hz 100/115 V, 5060 Hz 24 V= 24 V, 5060 Hz
199 190 263 199 190 264 199 190 265 199 190 266
Version for mounting on a multiple connection plate. Coil with valve body
200/230 V, 5060 Hz 100/115 V, 5060 Hz 24 V= 24 V, 5060 Hz
199 190 267 199 190 268 199 190 269 199 190 270
Multiple manifold
4 position 6 position 6 position Blank cover plate with 1 O-ring and 2 screws
199 190 271 199 190 272 199 190 273 199 190 274
Diagram of connections for Accessories PA10/PA20
Mechanical auxiliary switch Wiring diagram 199 190 131 Closed Open 199 190 134 Potentiometer Wiring diagram 199 190 132
CW CCW
14
2
14
2 1 2 3
3
2
1
3
2
1
Both switches are prewelded as normally open A change in the connection welding from 4 to 2 provides a normally closed function.
Inductive auxiliary switch Wiring diagram 199 190 136 NPN 199 190 137 PNP
Closed
Open
Inductive auxiliary switch Wiring diagram 199 190 133 Namur
Closed
Open
3
2
1
2
1
3
+ + NPN PNP + +
Single parts / Spare parts Pneumatic actuator type PA10/PA20
Type PA 10 PA 10 PA 10 PA 20 PA 20 PA 20
Function FC FO DA FC FO DA
DN 1025 1025 1025 3250 3250 3250
Code 198 150 340 198 150 342 198 150 344 198 150 341 198 150 343 198 150 345
Position Cover set including: 1 2 3 4 5 6 7 8
Description Display-label PT screw PT screw Cover O-ring O-ring O-ring O-ring
Part 1 2 1 1 2 2 2 1
Material Box steel Steel Steel SAN transp. NBR NBR NBR NBR
Code 198 000 196
Spare parts set including:
198 000 197
Intermediate element for type 201/202/203
d DN Intermediate mm mm Inch element 16 20 25 32 40 50 63 10 15 20 25 32 40 50 198 198 198 1 198 11/2 198 13/4 198 2 198
3 1 3
Manual override 198 198 198 198 198 198 198 000 000 000 000 000 000 000 100 100 101 102 103 104 105
/8 /2 /4
000 000 000 000 000 000 000
360 360 361 362 363 364 365
3-way ball valve 343 see documentation Fi 5396
Integrated, Universal Fixing System
The 3-way ball valve type 343 has an integrated fixing unit (insert screws in high-grade steel). The George Fischer mounting blocks are designed to allow different size George Fischer Valves to be aligned with the same pipe centre line by equalising the different heights from the base to the centre line of the pipe. [. . . ] Mounting blocks: material PP-GF 15, black, 3 sizes
Mounting blocks 3-way ball valve type 343 horizontal Types/dimensions
d
DN
Inch
3
Code
H mm 1 3. 5 15 15 11
L2 mm 25 25 25 45
L3 mm 17 17 17 22
L1 mm 42 42 42 67
L mm 46. 5 46. 5 46. 5 80
D mm 7. 5 7. 5 7. 5 9. 5
H1 mm 8 8 9
Weight g 14 16 16 28
/81/2 167 480 423 167 482 238 2532 2025 3/41 167 482 238 1 4063 3250 1 /42 167 482 239
1)
16/20 1) 10/15
For dimensions DN 10/15, the two mounting blocks have to be ordered separately. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GEORG FISCHER PA30
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GEORG FISCHER PA30 will begin.