User manual GRACO PROCONTROL 1KS INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GRACO PROCONTROL 1KS. We hope that this GRACO PROCONTROL 1KS user guide will be useful to you.


GRACO PROCONTROL 1KS INSTALLATION: Download the complete user guide (3307 Ko)

Manual abstract: user guide GRACO PROCONTROL 1KSINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Installation ProControlTM 1KS Approved for use in explosive atmospheres (except the EasyKey). Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 3A1163A ENG Automatic system for fluid management of single component coatings. For professional use only. See pages 4-5 for model information, including maximum working pressure. [. . . ] ProControl 1KS System Layout Drawing 3A1163A Air In Optional Color Change Module Air Control Module 5/32" Color Valve Air Supply 1/4" Logic Air Supply 1/4" V/P Air Supply 1/4" Purge Air Supply Fluid In Fluid System Control Box Fluid Supply 10' Flow Control Cable Flow Control Regulator Module Fluid Supply Optional Booth Control Fluid Out 5/32" Air On/Off Lines for Dose, Air Purge, and Solvent Purge Valves Solvent Supply Meter Cable Fluid Manifold and Flow Meter EasyKey Interface (with display) 50' I/S Power Cable 50' Fiber Optic Cable Optional Color Change Valves Wall Mounting TI16329a 15 Wall Mounting 16 3A1163A Air Supply Air Supply Requirements · · Compressed air supply pressure: 75-100 psi (517-700 kPa, 5. 2-7 bar). Air hoses: use grounded hoses that are correctly sized for your system. 4. lnstall a bleed-type shutoff valve into the air purge valve inlet line. Use the air purge valve tubing (AT, supplied) to connect the air purge valve (APV) inlet to a clean, dry air supply (install filters/dryers as needed). NOTICE The ProControl potlife timer will not function properly when used with multiple guns operating simultaneously. To avoid having mixed material set in the equipment, carefully monitor potlife by some other means. Trapped air can cause a pump or dispense valve to cycle unexpectedly, which could result in serious injury from splashing or moving parts. · Air regulator and bleed-type shutoff valve: include in each air line to fluid supply equipment. Install an additional shutoff valve upstream of all air line accessories to isolate them for servicing. Air line filter: a 10 micron or better air filter is recommended to filter oil and water out of the air supply and help avoid paint contamination and clogged solenoids. If using a Graco electrostatic PROTM Gun, a shutoff valve must be installed in the gun air line to shutoff the atomizing and turbine air to the gun. Contact your Graco distributor for information on air shutoff valves for electrostatic applications. · 1 Install a bleed-type air shutoff valve here. Main Air Inlet Air Connections See the System Pneumatic Schematic on page 29. Tighten all ProControl system air and fluid line connections as they may have loosened during shipment. Install a bleed-type air shutoff valve into the control air filter inlet. NOTICE Use separate air supply lines for the following two connections to avoid contaminating the purge air line with fluid if the air purge valve and a check valve failed. This air line supplies air to operate the gun, solenoids, and dispense valves. NOTE: See Technical Data on page 35 for additional air supply/consumption information. 1 For Air Purge Valve For Air Flow Switch Air Filters FIG. Air Supply Control 1 For Fluid Station Controls TI11895a 3A1163A 17 Fluid Supply Fluid Supply Requirements Fluid Connections 1. Connect the solvent supply line to the 1/4 npt(f) solvent purge valve inlet. Multiple color system: also connect a solvent supply line to the color change stack (Q), top valve 4 or 5. 7. Do not exceed the pressure rating of the lowest rated component. To reduce the risk of injury, including fluid injection, you must install a shutoff valve between each fluid supply line and the fluid manifold assembly. ProControl models are available to operate air spray or air-assisted systems with a capacity of up to 3800 cc/min. [. . . ] 303, 304 SST, Tungsten carbide (with nickel binder), perfluoroelastomer; PTFE * Dependent on programmed K-factor and application. The maximum allowable flow meter pulse frequency is 425 Hz (pulses/sec). For more detailed information on viscosities, flow rates, or mixing ratios, consult your Graco distributor. See individual component manuals for additional technical data. 3A1163A 35 Graco Standard Warranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO PROCONTROL 1KS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO PROCONTROL 1KS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.