Detailed instructions for use are in the User's Guide.
[. . . ] Always remember to unplug the air conditioner before openning inlet grill. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment. The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after Do not damage any parts of the air adequate recycling. [. . . ] Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
POWER/SOFT
14
Air Conditioner
Edition:2006/1/10
Operation
HEALTH operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts. Health function includes health anion function, UV light degerming function.
2. Health anion function
Press HEALTH button. (It's available under any mode)
POWER/SOFT
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
BRIEF INTRODUCTION TO HEALTH ANION FUCTION
The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
15
Air Conditioner
Edition:2006/1/10
Operation
Auto Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select DRY operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature.
POWER/SOFT
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
COOL operation starts when room temp. is higher than temp. setting. Temp. setting+2oC Temp. setting
Ultra-low air flow
Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting.
5. Unit stop
On reaching temp. setting +2oC unit will run in mild DRY mode.
Press ON/OFF button, the unit stops.
18
Air Conditioner
Edition:2006/1/10
Operation
Fan Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select FAN operation
3. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
POWER/SOFT
LOW
MED
HI
4. Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available.
19
Air Conditioner
Edition:2006/1/10
Operation
Heat Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select HEAT operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature.
POWER/SOFT
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
20
Air Conditioner
Edition:2006/1/10
Operation
Air Flow Direction Adjustment
1. Status display of air sending
Vertical flap
Pos. 1 Pos. 2 Pos. 3 Pos. 4
POWER/SOFT
Pos. 5 Pos. 6
(Auto swing)
2. Up and down air flow direction
For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 6 remote controller: : HEAT: remote controller: AUTO: remote controller:
Pos. 5 Pos. 4 Pos. 3 Pos. 2 Pos. 1 Pos. 6
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pos. 5
Pos. 6
The vertical flap will swing according to the above positions Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
21
Air Conditioner
Edition:2006/1/10
Operation
Sleep Operation
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. setting so that room temperature won't be too Iow for your sleep.
SLEEP operation starts SLEEP operation stops Approx. 6hrs Rises 1OC 1 hr
1 hr
Rises 1OC
Temp. setting
Unit stop
In COOL, DRY mode
Remote Controller
2. In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. [. . . ] When the remote controller is manipulated, it gets the system back to the normal operation mode. 27
Air Conditioner
Edition:2006/1/10
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Do not block the air inlet or outlet
Close doors and windows during operation
Use the timer effectively
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch.
OFF
28
Air Conditioner
Edition:2006/1/10
Maintenance
For Smart Use of The Air Conditioner WARNING
Before maintenance, be sure to turn off the system and the circuit breaker.
Remote Controller
Indoor Body
Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth.
Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping. then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline, benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40 C(104 F) may cause discoloring or deformation.
O
O
Air Filter cleaning
Open the inlet grille by pulling it upward. Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
POWER
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects.
Once every two weeks
Close the inlet grille.
29
Air Conditioner
Edition:2006/1/10
Maintenance
Replancement of Air Purifying Filter
1. Open the lnlet Grille
Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up)
2. Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3. Detach old Air Purifying Filter 4. Attach old Air Purifying Filter
Detach old Air Purifying Filter Put air purifying filter appliances into the right and left filter frames .
5. Attach the standard air filter
(Necessary installation) Close the Grille surely
6. Close the Inlet Grille NOTE:
The air purifying filter of the bacteria-killing medium and the electrostatic air purifying filter accessories with machine will be used based on real situation. The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. [. . . ]