[. . . ] If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Indoor Unit
Selection of Installation Place
280
Outdoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. Place, possible to drain easily, where piping can be connected with the outdoor unit. Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. [. . . ] In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
3
30mm
Indoor unit
1. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Heat insulation material Lid for right piping Lid for under piping Lid for left piping Drain hose
Piping
Indoor/outdoor electric cable
Fix with adhesive tape
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
[Other direction piping]
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the mounting plate. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly.
mounting plate
Unloading of indoor unit body
When you unload the indoor unit, please use your hand to arise the body to leave agraffe, then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate.
agraffe
mounting plate
4
Indoor unit
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. If the fuse on PC board is broken please change it with the type of T. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm.
1( ) L ) N 3 4 (2
Indoor unit
Outdoor unit
1 L) 2 N) ( (
Indoor unit
HSU-07HEK03 HSU-09HEK03 HSU-12HEK03
Outdoor unit
HSU-07LEK03 HSU-09LEK03 HSU-12LEK03
HSU-09LEK13 HSU-12LEK13
connecting wiring: -mod 07-12: 3G1. 0mm Power cable: -mod 07-12: 3G1. 0mm
connecting wiring: 5G1. 0mm -mod 07-12: Power cable: -mod 07-12:
3G1. 0mm
5
Outdoor unit
Outdoor unit 1. Installation of Outdoor Unit
Install according to Drawing for the installation of indoor and outdoor units
2. Connection of pipes
To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m.
Half union
Flare nut
Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque
18N. m 42N. m 50N. m
Liquid side 6. 35mm(1/4") Gas side 9. 52mm(3/8")
Spanner
Torque wrench
Gas side 12. 7mm(1/2")
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
3. Connection
Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. [. . . ] Only for first installation, this extra 50g can be used to purge air in pipes. (This must be strictly controlled within 90o and 10 sec. )
7
1. Power Source Installation
The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible.
2. Cutting and Flaring Work of Piping
Pipe cutting is carried out with a pipe cutter and burs must be removed. [. . . ]