User manual HAIER HWR12XC5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAIER HWR12XC5. We hope that this HAIER HWR12XC5 user guide will be useful to you.


HAIER HWR12XC5 : Download the complete user guide (4084 Ko)

You may also download the following manuals related to this product:

   HAIER HWR12XC5 (1164 ko)

Manual abstract: user guide HAIER HWR12XC5

Detailed instructions for use are in the User's Guide.

[. . . ] Electrostatic Filter (not all models) The Fresh Air Vent allows the air conditioner to Being constructed of high efficiency purifying recirculate inside air, draw fresh air into the room substance, active carbon fabric, electrostatic fabric, and exhaust stale air to the outside . electrostatic active carbon net and other materials it purifies the air effectively. Its wavy structure increases the capability to filter dust and smoke effectively. [. . . ] Open the inlet grille by pulling the exposed door on the top of the unit and remove the screw which fasten the front panel. Remove the screws which fasten the cabinet at both sides and at the back. Slide the unit from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet. Caution: Never expose plastic front or grille to extreme temperatures. Shipping Screws 3 ASSEMBLE CURTAINS/TOP RAIL Install top rail with three 13/32"screws. Slide left-hand curtain assembly into left end of top and bottom rails. Fasten curtain retainer strips to sides of outer case with eight 13/32" screws. 4 Storm window installation I stormwindow frame does not allow f adequate clearancebelow sl (1/2" il required), remove stormwindow frame or createclearanceby adding a Inspect window track, sash, and sill wood strip (at least1 1/2" wide) along for its ability to support the weight of entire width of sl. to sl with at leastthreecountersunk il wood screws(not suppliedwith k t . i) Measure width between window Thisprovidesa smooth surface for moldings to ensure Instant Mount mounting air conditioner . Instant Mount 12 /" models are designed for windows Min i mum wide (the detail see page 15) 1 12 /" M n imum i W ood Si tp r SL IL I N D O O R S orm Wi ndo w t Fram e PREPARE WINDOW FOR INSTALLTION Mobile home window installation Add wood strip (at least1 1/2" wide) along entire width of window sl. il Thickness wood strip shouldmatch of height of front lp on window frame. i Fastenwood strip to sl with a il minimum of threecountersunk wood screws(not suppliedwith k t . This i) providesa smooth surface for mounting air conditioner . Mus tbe a mn mum ii o 12 t l e r f /" o c a bto m r on ui ot a i l nt 11 2 /" Minimum W ood Sr ti p Window Frame Instant Mount kit supplied with unit is designed for mounting in most double-hung windows without storm windows. For installation in window frame with storm window, modify sill by adding wood strips (not included) to inner and outer sills. This raises unit and eliminates interference of storm window frame. O U T D O O R I N D O O R O U T D O O R English 5 e t i h c h a s l a f e P s o b INSTALL OUTER CASE IN WINDOW T rail op About 5 Bottom rail i a a t r n u i c a t r hu tC o a t rt oA f . y e am wa ar u hsas wo b f d d w w n o a d p n e x i h E w t n i i i s p e a c e a n a r s a w l e l e r i l c r c s d h e : , g k E a Tm O evir uorh N d t o T s w e r c s 3 e s U English 6 lat h wod e , sem tro a o noit w s t n d a n i i i r I w w s f I A A f pm dd sl cnu INSTALL SASH BRACKET & SEAL GASKET tuC laes roodni eiey fcn ic . 7 INSTALL DRAIN TUBE 8 RETURN CHASSIS TO OUTER CASE Find someone to help you replace chassis in outer case. (Don't forget to install the attachment screws before replacing grille) Caution: For security purpose, reinstall screws at cabinet's sides. Important: Because window sash helps keep unit in window, make certain window sash contacts outer case before reinstalling chassis. English CareCleaning and Guide Always unplug your air conditioner before cleaning. The air filter behind the inlet grille should be checked and cleaned at once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. The grille may be opened from the top for easy maintenance after inst 2. [. . . ] Temperature setting may be too cold, Unit BTU may be too high for the room. English Air conditioner working but room not cooling: Room may have appliances that produce heat. Al doors and windows need to be closed so cool air does not escape the room. On extreme hot & humid days air conditioners may take a little longer to cool Vent may be in the open position. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HWR12XC5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HWR12XC5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.