User manual KUSSMAUL 091-89

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KUSSMAUL 091-89. We hope that this KUSSMAUL 091-89 user guide will be useful to you.


KUSSMAUL 091-89 : Download the complete user guide (141 Ko)

Manual abstract: user guide KUSSMAUL 091-89

Detailed instructions for use are in the User's Guide.

[. . . ] file: 091-89-12. p65 Rev. A 10-27-2004 INSTRUCTION MANUAL AUTO CHARGE 4000 AUTOMATIC BATTERY CHARGER MODEL #091-89-12 NOTE : This charger is designed for vehicles with dual batteries and negative ground. INPUT :120 volt, 50/60 Hz, 8 amps OUTPUT: 40 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO. , INC. 170 CHERRY AVE. , WEST SAYVILLE, N. Y. [. . . ] This current limits the output current to the rated 40 amperes when charging a deeply discharged battery or if the starter cranks the engine while charging. The current limiter thus eliminates the need for an ignition interlock circuit. BATTERY SAVER & INDICATOR A 5 ampere BATTERY SAVER is built into the charger. When connected as shown in the installation wiring diagram, loads on the battery such as radios and rechargeable hand lights are automatically switched to the BATTERY SAVER when power is applied to the charger. The BATTERY SAVER allows more efficient charging by removing these loads. A BATTERY SAVER overload indicator alerts the operator that the BATTERY SAVER load has exceeded 5 amperes. WHEN A BATTERY SAVER OVERLOAD OCCURS: a. Reapply the load to the BATTERY SAVER No fuses are required or provided as the BATTERY SAVER contains an automatic circuit breaker. REMOTE BATTERY CHARGE CONDITION INDICATOR This remote indicator shows the charge condition of each battery in 10 levels from "LOW CHARGE" to "FULLY CHARGED". This device indicates a defective battery when a bar graph does not rise to the "FULLY CHARGED" level after an extended period of charging. NOTE: If a battery is being discharged with an external load of 1. 5 to 6 amperes across it's terminals, the bar graph may move down 1 or 2 levels. To avoid this, connect all external loads to the BATTERY SAVER terminals. Loads connected to the BATTERY SAVER will be powered either from the BATTERY SAVER power supply when the A. C. power is "ON", or they will be connected to battery #1 when the A. C. power is "OFF". Installation Wiring Diagram Auto Charge 4000 POWER Indicator BATTERY SAVER OVERLOAD REMOTE DISPLAY 4 3 2 1 BATTERY SAVER POSITIVE COM BAT 1 BAT 2 A. C. POWER Strip insulation 15/32 so that wire strands are flush with end of eyelet, 2 places +1 2 Volt s Chassis Ground Battery Saver Loads (5 amps max. ). When the charger is disconnected from 120 volts AC the Battery Saver loads automatically are connected to battery #1. [. . . ] shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KUSSMAUL 091-89




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KUSSMAUL 091-89 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.