User manual LIFT-MASTER LM21-AFC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER LM21-AFC. We hope that this LIFT-MASTER LM21-AFC user guide will be useful to you.


LIFT-MASTER LM21-AFC : Download the complete user guide (629 Ko)

Manual abstract: user guide LIFT-MASTER LM21-AFC

Detailed instructions for use are in the User's Guide.

[. . . ] RELEASE DEVICES MADE IN THE U. S. A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL The LiftMaster Fire Control (LM21-AFC) Release Device/Control Panel is UL/CUL listed normally energized fail-safe device incorporating state of the art electronic control circuitry. The LM21-AFC is designed to be used with manual doors or motorized doors incorporating a reversing feature safety edge to create an automated door closing system. The LM21-AFC high performance control panel responds to emergency conditions generated by manual or automatic initiating devices. Upon activation from such a device, the unit will then automatically close a motorized door or release a manual door. [. . . ] limit to toggle 3 before operator limit when door is traveling toward open position. (Supervised, current-limited circuit) Note: Electrical loops must be provided as dry contacts and may not be used in conjunction with the simultaneous switching of a motor control or any other voltage through the same contacts. Connections of this type will result in immediate damage to the release device. Figure 5 Auxiliary Limit Switch Connections 8. Motor control relay (Motorized doors only) - Connect wiring from 7, 8, 9 & 10 across motor control 3-button station (For use with N/O `Close' switch, N/O `Open' switch and N/C `Stop' switch). The Close relay output latches to initiate a door closure through the operator after a 10-second delay (20-sec. (Figure 6) The Open relay is used to open the door when the Auto-Open feature is enabled. Figure 6 - Operator Electrical Connections Remote test station. - (Optional) This optional device (part number SSRT) disables the cycle counter to allow testing of the door without a mechanical release after 3 cycles. Connect N/O remote test switch common to 21 and 22 as illustrated in Figure 7. Annunciator - (Optional) Connect annunciator (part number SSHS2475ADA) to 16 (+) & 20 (-) as illustrated in Figure 7. UL/CUL listed end-of-line resistor (2. 2k Ohm @ ¼ Watt) must be placed installed as illustrated. Multiple annunciators may be connected but the maximum output current of the devices must not exceed . 75A DC. Additional dry contact relay is provided between 17 (Input) and 18 (N/C Output) and 19 (N/O Output) as illustrated in Figure 7. 9. Figure 7 - Electrical Connections for Annunciator and Test Plate 4 DIP-Switch Options The LM21-AFC has six DIP-switch selectable options. The options DIP-switch is located next to terminal block 5 as illustrated in Figure 2. The selection of positions is listed below. DIP Sw itch Position 1 Sw itch 'On' Motorized door. The LM21-AFC will attempt to close the door with the motor before releasing. If a motorized door is used, the LM21-AFC will attempt to close the door but will reverse if the safety edge is triggered. The LM21-AFC will stop the door on the obstruction when it is sensed the third time. The LM21-AFC will have a 20 second delay after an alarm is sensed before performing a door closure or drop. The LM21-AFC will drop the door after 6 minutes if close limit is not achieved by a motorized closure. Treat a loss of line power as an alarm, which leads to door closure, or drop. The LM21-AFC will drop the door without attempting to close it with a motor. [. . . ] Depress and continue to hold the "Test" button on side of release device. Annunciator will sound indicating a door closure is about to occur and after factory set 10-second alarm verification delay (or 20-sec. This test verifies a mechanical release in absence of power to the motor. Reset fire door release mechanism, then reset LM21-AFC release mechanism by pressing mechanical reset plunger. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LM21-AFC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LM21-AFC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.