User manual MITSUBISHI LMAP03U-E NETWORK VARIABLE SPECS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MITSUBISHI LMAP03U-E. We hope that this MITSUBISHI LMAP03U-E user guide will be useful to you.


MITSUBISHI LMAP03U-E NETWORK VARIABLE SPECS: Download the complete user guide (1336 Ko)

Manual abstract: user guide MITSUBISHI LMAP03U-ENETWORK VARIABLE SPECS

Detailed instructions for use are in the User's Guide.

[. . . ] 03_NVspec_ver304e Version3. 04 2003. 02. 05 AIR CONDITIONER INTERFACE LM ADAPTER MODEL: LMAP03U-E Network Variables Specification 1 2 3 4 5 6 Specification Object Details SNVT Table Network Variables Configuration Properties Node Object P. 2 - 3 P. 4 - 9 P. 10 - 13 P. 14 - 35 P. 36 - 48 P. 49 Appendix A: Fahrenheit conversion of Centigrade data ProgramID: 9-000A2-0076-0003-03 XIF: 0303lm30. xif *1. LONWORKS® , and the Echelon logo are trademarks of Echelon Corporation registered in the United States and other countries. *4. XIF is of operation check settled in LonMaker for Windows 3. 0(SP2). MITSUBISHI ELECTRIC MITSUBISHI ELECTRIC CORPORATION AIR-CONDITIONING & REFRIGERATION SYSTEMS WORKS WSN02-2124 -1- 03_NVspec_ver304e 1. Specification 1-1. Object Model These specifications apply to the communication interface used to connect the LonWorks network and the Mitsubishi Electric M-NET compatible products. <Model name> 1. Split-type air conditioners Mr. SLIM NOTE:A-M Converter(PAC-SF48MA-E) is necessary. 3. Heat recovery ventilators LOSSNAY NOTE:LOSSNAY Adapter(PZ-53ADF-E) is necessary. 1-2. Explanation of Function Setting This product requires a function setting switch because of the connected model, system configuration and control functions. SW NO. [. . . ] If an error occurs in an outdoor unit, the indoor unit will also stop with an error. Thus, the error will be output from all indoor units in the same refrigerant system. (However indoor units under stopping are excluded. ) Valid Range 0255 = Error Unit Address 65, 535 = Normal *The value is 0 while LM ADAPTER is initialized. When Transmitted This variable is transmitted promptly as the state changes. This variable is also transmitted as the state changes by the operation from the local side such as a local remote controller. This variable is output by the ncilnitStartTm (Initialize Start Time) at the powering of LM ADAPTER. Update Rate The maximum update rate is not available. Default Service Type Acknowledged NOTE: 1: The release of the indoor unit nvoErrAdrs_n(Error Unit Address) results in the "Off" command of the nviOnOff_n (Request On/Off). For the nvoErrAdrs_n(Error Unit Address) when the indoor unit is under stopping, transmit "Off", after transmitting "On". 2: The error is not output when the indoor unit is stopped, so always use together with the local remote controller or system controller. WSN02-2124 - 26 - 03_NVspec_ver304e 26n Thermo On/Off state_1 network output SNVT_state nvoThermo_n; This output network variable indicates the On/Off state of the indoor unit , the thermostat and the auxiliary heater for heating. This variable is used to calculate the electric charge. Valid Range bit[2] bit[1] 0 1 bit[0] 0 1 status Indoor OFF Indoor ON Indoor thermostat OFF Indoor thermostat ON Supplementary heater OFF Supplementary heater ON 0 1 *The value is 0 while LM ADAPTER is initialized. When Transmitted This variable is transmitted promptly when the state changes. This variable is output by the ncilnitStartTm (Initialize Start Time) at the powering of LM ADAPTER. Update Rate The value designated by nciMinOutTm (Minimum Send Time) is valid. Default Service Type Acknowledged NOTE: This output value is not the addition value or proportional division value of electric charge. It is necessary to perform addition and proportional division based on this output value. 26n Thermo On/Off state 2 network output SNVT_switch nvoThermo_n; This output network variable indicates the On/Off state of the indoor unit. This variable is used to calculate the electric charge. Valid Range Thermostat State Indoor thermostat OFF SW1-7OFF state 0 value 0 0 state 0 1 SW1-7O value 0 100% Indoor thermostat ON 1 *The value is 0 while LM ADAPTER is initialized. When Transmitted This variable is transmitted promptly when the state changes. This variable is output by the ncilnitStartTm (Initialize Start Time) at the powering of LM ADAPTER. Update Rate The value designated by nciMinOutTm (Minimum Send Time) is valid. Default Service Type Acknowledged NOTE: This output value is not the addition value or proportional division value of electric charge. It is necessary to perform addition and proportional division based on this output value. WSN02-2124 - 27 - 03_NVspec_ver304e 28n Model Code network output SNVT_count nvoIcMdlSize_n; This output network variable indicates the model code that indicates the indoor unit. This variable is used to calculate the electric charge. Valid Range 065, 534 *The value is 0 while LM ADAPTER is initialized. When Transmitted This variable is transmitted promptly when the state changes. Monitoring with a Poll request or Fetch request is required. Update Rate The maximum update rate is not available. Default Service Type Acknowledged WSN02-2124 - 28 - 03_NVspec_ver304e 29n Group number network output SNVT_count nvoGroupNo_n; This output network variable indicates the group number of the indoor unit. Valid Range 050 *The value is 0 while LM ADAPTER is initialized. When Transmitted This variable is transmitted promptly when the state changes. Monitoring with a Poll request or Fetch request is required. Update Rate The maximum update rate is not available. Default Service Type Acknowledged NOTE: The group number set up by the system controller is outputted. WSN02-2124 - 29 - 03_NVspec_ver304e 1 Request All Off network input SNVT_switch nviAllOff; This input network variable is used for the emergency Off of the indoor unit and all ventilation. Under the output of "Emergency OFF" of nvoAllOff cannot operate from other remote controller , system controller. The ON/OFF input for each indoor unit from the master system will be ignored. The emergency stop valid time is set with nciEffectTm_1 (Effective time 1). The indoor unit will not start even if the emergency stop is cancelled. Valid Range SW1-7OFF state emergency OFF 0 value not used state 0 SW1-7O value not used 0 1 (*1) *1:The setting to state=0x02-0xFE is interpreted as state=0x01. *This operation is not carried out when there are inputs other than the above. [. . . ] *2:The setting to over 100% is interpreted as 100%. Default Value 0(All switches) NOTE: It is possible to use with an "ME" remote controller. WSN02-2124 - 46 - 03_NVspec_ver304e 37 Local Display_1 network input config SNVT_switch nciRmDsp_1; This configuration property defines the presence of the automatic actual operation mode display on the local remote controller. The value is set according to nviRmLck (Request Simplified Locking) and nviRmLim (Request Limit Temperature Setting Range). Valid Range Display display no display SW1-7OFF state 0 else value not used state 0 SW1-7O value not used not used 1 (*1) 0 1 not used 1 (*1) 0. 5% - 100% (*2) *1:The setting to state=0x02-0xFE is interpreted as state=0x01. *2:The setting to over 100% is interpreted as 100%. Default Value 0(display) NOTE: It is possible to use with an "ME" remote controller. 38 Local Display_2 network input config SNVT_switch nciRmDsp_2; This configuration property defines the presence of the automatic actual operation mode display on the local remote controller. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MITSUBISHI LMAP03U-E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MITSUBISHI LMAP03U-E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.