User manual REGIN OPTIGO OP10-230

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual REGIN OPTIGO OP10-230. We hope that this REGIN OPTIGO OP10-230 user guide will be useful to you.


REGIN OPTIGO OP10-230 : Download the complete user guide (2980 Ko)

Manual abstract: user guide REGIN OPTIGO OP10-230

Detailed instructions for use are in the User's Guide.

[. . . ] Radiator circuit control with outdoor curve The water temperature setpoint is changed according to the outdoor temperature. A room temperature sensor can be added to give corrective action if the room temperature differs from the setpoint. The display menu system is divided into three levels, the configuration level (10-second level), the clock and scheduler level (3-second level) and the basic level. The configuration level (10-second level) This level is shown the first time the unit is connected. [. . . ] Set the first on-time to day 8 (which corresponds to every day Monday through Friday) and 7:30, the first off-time to day 8 and 18:00. Set the second on-time to day 6 (the sixth day of the week) and 8:00 and the second off-time to day 6 and 14:00. There the present output status of the scheduler is shown and you can manually override the setting. If, for example, the switch is shown as ON and you change it to OFF it will remain off either until you manually change it to On again or until the next timer ON-point is reached. A click on the encoder knob will exit the Time and Scheduler level and return you to the Base Display. Control mode 4 Control mode 4 uses the scheduler for switching to economy mode (ECO) where the temperature is lowered by a settable number of degrees. The ON-points will switch ECOnomy period on and the OFFpoints will switch back to comfort temperature. Example: Every weekday morning you want the temperature to start rising at 06:00 and remain at comfort level until 21:00. Set first on-time to day 8 and 21:00, the first off-time to day 8 and 06:00. Set the second on-time to day 6 and 23:30 and the second offtime to day 6 and 07:00. Set the third on-time to day 7 and 23:30 and the third off-time to day 7 and 07:00. In this menu you set the number of degrees you wish to lower the room temperature setpoint during the economy periods. If no room sensor is connected the supply water setpoint will be lowered by 3 times the set value. A click on the encoder knob will exit the Clock and Scheduler level and return you to the Base Display. The basic level The Base Display is shown when there is no operator activity. Choose control mode in menu level 0 by clicking on the knob so the "Menu holds changeable values" symbol (see the section Display symbols below) starts flashing, and then turning the knob. When the control mode you want to choose is displayed, click once more on the knob so the "Menu holds changeable values" symbol stops flashing. When you have chosen the control mode, you move between the menu levels by turning the knob when the "Menu holds changeable values" symbol is not flashing. This sample display shows that the time is 13:48 on a Friday, the fifth day of the week. to set the clock , click the knob and the day-of-the-week number will start flashing. Turn the knob until the correct day is shown, Monday is 1, Tuesday 2 etc, and then click the knob again to acknowledge the choice. After confirming the minutes the menu will change to show the first of the scheduler menus. [. . . ] OP10 can be reset to factory settings by configuring Domestic hot water control (mode 5) and setting the D-factor to 99. When power is reapplied all configuration and scheduler settings will be reset to factory setting. Sätt den andra till-tiden till dag 6 (veckans sjätte dag) och 8:00 och den andra från-tiden till dag 6 och 14:00. Om man till exempel ändrar omkopplaren från ON till OFF kommer den att vara från tills man manuellt ändrar tillbaka den till ON, eller till nästa ON-punkt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE REGIN OPTIGO OP10-230




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual REGIN OPTIGO OP10-230 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.