User manual SABINE GRQ3122-S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SABINE GRQ3122-S. We hope that this SABINE GRQ3122-S user guide will be useful to you.


SABINE GRQ3122-S : Download the complete user guide (3853 Ko)

Manual abstract: user guide SABINE GRQ3122-S

Detailed instructions for use are in the User's Guide.

[. . . ] SUMMARY Summary of Features OF FEATURES GRQ3121 (1U, single channel, one input, two outputs) GRQ3122 (2U, dual channel, one input & output per channel) GRQ3121-S (1U, blank front panel slave, single channel, one input, two outputs) GRQ3122-S (1U, blank front panel slave, dual channel, one input & output per channel) GRQ2 Remote for WindowsTM Software included with every unit; runs up to 8 Graphi-Q2s per COM port (maximum of 2 COM ports) · All front panel controls are analog-style; signal path is digital · "Tweek-n-Peek" feature: Front panel adjustments of all parameters are shown in LED display screen · 24-bit A/D and D/A conversion, 32-bit processing · 20 to 20 KHz Frequency Response · +18 dBV Maximum Signal Input & Output · Floating Point SHARC Processor · >110 dB dynamic range Each channel provides (now with fully independent processing on 1x2 units): · 31-band graphic EQ, with ± 6 or 12 dB range (selectable) · Crossover: Bessel, Butterworth, and Linkwitz Reily filters; slopes to 48 dB/octave (Software only) · High Cut Filter (3KHz to 20KHz) and Low Cut Filter (20 Hz to 1KHz) · FBX Feedback Exterminator: up to 12 Filters, with Setup Mode (Auto Setup Mode via remote control) · Parametric Filters: up to 12 filters, numeric or graphic control (Software only) · Compressor/Limiter, with controls for ratio, threshold, and gain (attack, release, and knee adjustable with remote) · Digital Delay, with up to 1 second delay, adjustable in 20 microsecond increments · Bypass: dedicated switches for FBX, EQ, and Delay with built in LED indicators · LED Segmented Indicators: FBX Filters, Level, Gain Reduction · LED Point Indicators: FBX Setup, Remote, EQ Range · LED Character Display: Delay setting, EQ fader boost/cut, High Cut Filter setting Low Cut Filter setting, Compressor Ratio, Threshold, Gain, and Staus Messages. Back Panel: · XLR & 1/4" TRS inputs & outputs · RS-232 Serial input & output (additional serial input on the slave front panels) · Remote switching (8-position contact closure switch; allows switch selection of all 20 stored GraphiQ2 presets) Graphi-Q2 Remote Software Features: All front panel controls, plus more, including: · FBX filter depth & width adjustments; switchable to parametric filters (depth, width & frequency adjustments) · Graphic EQ filter width adjustments · Password protection · View & edit frequency response curves · 20 user-defined stored presets · · Control and link up to 8 Graphi-Q2s (16 channels of audio) per COM port (1 or 2 ports can be used) Future-proof FREE Flash RAM upgrade capability: upgrade your firmware and software from the Sabine website (www. Sabine. com)! Operating Guide Version 1: for Sabine Graphi-Q2s with: · GRQ2 Firmware Version 2. 20 · GRQ2 Remote Software Version 5. 0 1 B1-GRQ-2-OpGuide-v1-050125. pmd DECLARATION OF CONFORMITY EC - DECLARATION OF CONFORMITY CE MARKING We, the Manufacturer SABINE, INC. 13301 NW US HIGHWAY 441 ALACHUA, FLORIDA USA declare that the product EQUALIZER SABINE MODEL GRQ3100 Is in conformity with Council Directive: 73/23/EEC and 89/336/EEC (EMC Directives) Standards to which conformity is declared: EN 60065: 1993 EN 60742: 1995 EN 55103-1: 1997 EN 55022: 08:94 + a1:05:05 EN 55103-2: 1997 Manufacturer's Signature: Date: October 31, 2002 Name: Doran Oster, Sabine President 2 TABLE OF CONTENTS Summary of Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Section One: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Compressor Linking Options for GRQ3122 and GRQ3122-S Models Just as with any other parameter setting, you may link compressor channels, left or right, within the same unit, or between multiple units, in either ABS or REL linked networks. However, for stereo programs, simply linking compressor settings of the left and right channels to be identical may not be appropriate. For example, if both channel A and channel B begin to compress when a peak level exceeds a certain threshold, and the sound engineer intentionally designs his audio program to have more sound in the left channel, that channel's sound will be compressed more readily than the right channel program. Since compression affects sound levels, such a setup will result in a difference in the balance of left-right channel output levels -- the stereo image will shift. To preserve channel balance yet still allow compression, Sabine offers another method of linking left and right channels of GRQ3102 and GRQ3102-S models: True Stereo compression. In True Stereo mode, both channels are compressed equally if the threshold is exceeded in either channel. There are two methods by which True Stereo compression can be selected (note that changing compressor link status by either method will automatically update the status report in the other screen): 1. In the Link Table, enter the letter "S" in the appropriate channel boxes, and click "Apply. " 2. In the Compressor/Limiter screen, you may toggle the box below the CLOSE button to engage either True Stereo or Dual Mono compressor modes. Because these models do not offer two discrete channel signal paths, True Stereo linking will not apply to such units. In a multiple unit Graphi-Q network, you may NOT apply a True Stereo link from one unit to another, but only between the left and right channels of a single unit. All the units in a network may have their L-R channels linked, but each link will be independent of other units. A GRQ3122 or GRQ3122-S unit with channels linked in True Stereo may not also be part of an ABS or REL link for compressor values. Of course other parameters may be linked (ABS or REL) independently of compressor relationships. Crossover Settings Because crossover settings are unique to a specific set of speakers and their environment, these settings are not available in the link table. When a crossover is in effect, be careful about linking other filters - you may attempt to control a filter that is not appropriate for the frequency response of a given output. Relative Linking and Scale Values All changes made to cells that are REL LINKED will increment or decrement by an identical number of steps in the scale of the parameter. For example, changing the compressor ratio in one REL LINKED cell from 1:1 to 1. 4:1 will result in a change in another REL LINKED cell from 10:1 to 16:1. Loading Memory Presets to Linked Units If you try to recall and load a stored memory (see Section 8. 6) to a unit with cells linked to any other unit, the screen shown at below will appear. 31 B2-GRQ-OpGuide-v9-031020. pmd SECTION EIGHT: USING GRQ2 REMOTE SOFTWARE If you elect to continue, the value your loaded memory puts into any linked cell on the chosen GraphiQ 2 will affect all other linked values as well. If you don't want this to happen, you must open the Link Table and remove the appropriate linking. Loading a preset that changes a linked parametric or sets an FBX filter back to an unset FBX filter will NOT load a corresponding filter change to linked channels. Linked channel FBX or parametric filters will remain unchanged unless your reset or manually program a change. [. . . ] The serial number affixed to the product is altered, defaced or removed; or e. In the event of a defect in material and/or workmanship covered by this limited warranty, Sabine will repair the defect in material or workmanship or replace the product, at Sabine's option; and provided, however, that, in any case, all costs of shipping, if necessary, are paid by you, the purchaser. THE WARRANTY REGISTRATION CARD SHOULD BE ACCURATELY COMPLETED, MAILED TO AND RECEIVED BY SABINE WITHIN FOURTEEN (14) DAYS FROM THE DATE OF YOUR PURCHASE. Bring the defective item to any Authorized SABINE DEALER and present therewith the ORIGINAL PROOF OF PURCHASE supplied to you by the AUTHORIZED SABINE DEALER in connection with your purchase from him of this product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SABINE GRQ3122-S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SABINE GRQ3122-S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.