User manual SATO CL608E SERVICE MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SATO CL608E. We hope that this SATO CL608E user guide will be useful to you.


SATO CL608E SERVICE MANUAL: Download the complete user guide (3431 Ko)

You may also download the following manuals related to this product:

   SATO CL608E OPERATOR MANUAL (877 ko)

Manual abstract: user guide SATO CL608ESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Charlotte, NC 28273 Main Phone: (704) 644-1650 Technical Support Hotline: (704) 644-1660 Fax: (704) 644-1661 http:\\www. satoamerica. com ã Copyright 2002 SATO America, Inc. The information supplied in this manual was current at time of publication. If you come across procedures that need clarification or find errors or have suggestions contact us at qc@satoamerica. com Warning: This equipment complies with the requirements in Part 15 of . CC rules for a Class B computing device. Operation of this equipment in a residential area may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps are necessary to correct the interference. No part of this document may be reproduced or issued to third parties in any form whatever without the express permission of SATO America, Inc. [. . . ] 9. print size small large test print press the feed key Press the . EED key for a test print. Press the . EED key again to stop printing. 10. Adjust the position using the VR1 potentiometer and feed another label. If the print position can't be adjusted with the VR1, replace the Main PCB. Refer to Section 6. SATO CL608e/CL612e Service Manual PN 9001079 Rev. Electric Checks and Adjustments 4. 6 Label Gap Adjustment Additional equipment required: TP Test Module Digital Multimeter STEP PROCEDURE Refer to Section 4. 2 for access to main PCB 1. 2. Turn VR4 (GAP) potentiometer on the main PCB all the way to the left. Attach the connector from the TP Test Module to the test port on the main PCB. Nibs on the connector are placed down in the receptacle on the PCB in the forward position. . or Low level (Label Gap part with backing only) adjustment, put label gap part in the sensor. Then adjust the electrical level with VR4 on the main PCB so that it will measure less than 0. 5 V . . or High level (paper part) adjustment, put paper part in the sensor and check the electrical level. If the level difference is +1. 0 V more than the Low level, it is acceptable. Standard values: Low level (gap): below 0. 5 V High level (paper part): Low level +1. 0 V or higher. If these values do not result, try the following: a) Repeat the process b) Clean the sensor c) Verify sensor is operational d) Replace labels with higher quality labels e) Perform factory reset 3. 4. 5. 6 Page 4-10 SATO CL608e/CL612e Service Manual PN 9001079 Rev. Electric Checks and Adjustments 4. 7 Eye-Mark Adjustment Additional equipment required: TP Test Module Digital Multimeter STEP PROCEDURE Refer to Section 4. 2 for access to main PCB 1. 2. Turn VR5 (IM) potentiometer on the main PCB all the way to the left. Attach the connector from the TP Test Module to the test port on the main PCB. Nibs on the connector are placed down in the receptacle on the PCB in the forward position. . or Low level (no "Eye-Mark" part) adjustment, put paper part in the sensor. Then adjust the electrical level with VR5 on the main PCB so that it will measure less than 0. 5 V . . or High level ("Eye-Mark" part) adjustment, put paper part with the "Eye-Mark" part in the sensor and check the electrical level. [. . . ] 1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30 CODE PA1721700 MA0301221 MT1300522 PA1721800 PA1721200 PL2720100 MD4300821 PD1720400 MD3401021 PA1721500 MD4300821 PB2720100 MD3401021 PR1720100 ND0060030 PR0720700 PL2720400 PE8720100 ND0040030 PE1720100 PB0720600 ND0040030 PE1720200 PE6720500 MD4300821 PV9720100 PC0720100 DESCRIPTION Head frame (LH) Pan head screw Hex nut Head frame (RH) Plate (adjust C) Adjust collar Pan head screw Stay Pan head screw Support plate (B) Pan head screw Collar Pan head screw Roller E-Ring Feed roller Bush Gear E-Ring Cam (head pressure) Shaft (head pressure) E-Ring Knob Protecter (B) Pan head screw Bush Spring (open) QTY 1 2 2 1 1 1 2 1 4 1 2 2 2 1 1 1 4 1 2 2 1 2 1 1 1 1 1 Page 10-20 SATO CL608e/CL612e Service Manual PN 9001079 Rev. 31 32 33 34 35 36 37 38 39 40 41 43 44 45 46 47 48 49 50 51 52 53 54 55 56 CODE PA1727100 PA1727200 PC1720100 PB2720200 PB2720300 PB2720400 MD4402021 MD4401021 PR1720200 MD4300821 PR1721400 PA1721400 MD4300621 PC1690201 MN1301630 RH1727700 RH1775201 GH000661A PB0723400 PR4721000 PR4721100 PA1721900 PA1722000 PC1720400 GH000511A DESCRIPTION Head Bracket (A) (CL608) Head Bracket (B) (CL608) Spring (head) (CL608) Collar Collar Collar Pan head screw Pan head screw Head sub holder (CL608) Pan head screw Head sub holder(CL612) Head cable cover Pan head screw Spring Hex hole bolt Power & Head Power Cord Set Print Head Cable Assy Print Head (CL608) Post (Head) Plate(Ribbon) (CL608) Plate(Ribbon) (CL612) Head bracket (A) (CL612) Head bracket (B) (CL612 Spring (head) (CL612) Print Head (CL612) QTY 1 1 2 1 2 1 1 3 1 2 1 1 2 2 2 1 1 1 2 1 1 1 1 2 1 PN 9001079 Rev. Parts List 10. 5 Ribbon Assembly Page 10-22 SATO CL608e/CL612e Service Manual PN 9001079 Rev. Parts List Ribbon Assembly Page 10-24 SATO CL608e/CL612e Service Manual PN 9001079 Rev. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SATO CL608E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SATO CL608E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.