User manual SMEG KIV90XT-1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SMEG KIV90XT-1. We hope that this SMEG KIV90XT-1 user guide will be useful to you.


SMEG KIV90XT-1 : Download the complete user guide (715 Ko)

You may also download the following manuals related to this product:

   SMEG KIV90XT-1 (836 ko)
   SMEG KIV90XT-1 (870 ko)

Manual abstract: user guide SMEG KIV90XT-1

Detailed instructions for use are in the User's Guide.

[. . . ] 21 NDICE PT CONSELHOS E SUGESTES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 CARACTERSTICAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 INSTALAO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 UTILIZAO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. EN 3 3 CHARACTERISTICS Dimensions Min 780 700 Max 1070 132 90 Min. 500mm 650mm 310 70 350 150 650 290 36 EN 4 4 Components Ref. 11 12c 12e 12f 12g 12h 12q 21 22 23 Q. ty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 Q. ty 4 6 2 2 4 4 4 1 8 4 Product Components Hood Canopy complete with: Controls, Lights, Filters Telescopic chimney made up of: Upper chimney Lower chimney Telescopic frame complete with Suction fan, made up of: Upper frame Lower frame Rh Air Outlet Directional Grille Lh Air Outlet Directional Grille Reduction flange 150-120 mm Dumper Air Outlet Connector Extension Air Outlet Connector Connection box Pipe clamps (not included) Cable clamps Finishing plug Installation Components Wall Plugs 10 Screws 2, 9 x 6, 5 Screws 2, 9 x 9, 5 Screws M4 x 80 Screws M6 x 80 Screws 5, 2 x 70 Screws 3, 5 x 9, 5 Drilling template 6. 4 mm int. dia washers M6 nuts 21 23 22 11 12h 7. 1a 12g 7. 1 14. 1 10 7. 1b 12c 2. 1 2 2. 2 8b 8a 12e 24 9 25 26 27 15 12c 1 12c 12f 22 12q Q. ty Documentation 1 Instruction booklet EN 5 5 INSTALLATION Drilling the Ceiling/shelf and fixing the frame DRILLING THE CEILING/SHELF ?Use a plumb line to mark the centre of the hob on the ceiling/support shelf. Place the drilling template 21 provided on the ceiling/support shelf, making sure that the template is in the correct position by lining up the axes of the template with those of the hob. For hollow brick ceilings with wall thickness of 20 mm: drill 10 mm(immediately insert the Dowels 11 supplied). For the air outlet (Ducted Version), drill according to the diameter of the external air exhaust duct connection. Insert two screws of the following type, crossing them and leaving 4-5 mm from the ceiling: ?For concrete ceilings, use the appropriate plugs for the screw size (not provided). For wooden shelf, use 4 screws 12g with washers 22 and nuts 23, provided. EN 6 6 Fixing the frame ?Loosen the two screws fastening the lower chimney and remove this from the lower frame. Loosen the two screws fastening the upper chimney and remove this from the upper frame. Unfasten the metric screws joining the two columns, located at the sides of the frame. Adjust the frame to the height required, then refit all the screws removed as above. Insert the upper chimney stack from above, and leave it running free on the frame. Lift up the frame, fit the frame slots onto the screws up to the slot end positions. Tighten the two screws and fasten the other two screws provided with the hood. Before tightening the screws completely it is possible to adjust the frame by turning it. [. . . ] Wash the Filters without bending them, and leave them to dry completely before replacing. Replace, taking care to ensure that the handle faces forwards. EN 1 11 Activated Charcoal Filter (Recirculation Version) ?This cannot be washed or regenerated, and must be changed when all the command LEDs start to flash, or at least once every 4 months. In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG KIV90XT-1




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG KIV90XT-1 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.