User manual SMEG WD5090

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SMEG WD5090. We hope that this SMEG WD5090 user guide will be useful to you.


SMEG WD5090 : Download the complete user guide (2841 Ko)

You may also download the following manuals related to this product:

   SMEG WD5090 ISTRUZIONI VARIE (1033 ko)

Manual abstract: user guide SMEG WD5090

Detailed instructions for use are in the User's Guide.

[. . . ] The product label, with the serial number, is sticked under the hob. The manufacturer refuses all responsibility for possible damages to things or people, resulting from a wrong installation or from an improper, incorrect or unreasonable use of this equipment 10 DESCRIPTION MOD. WD5090 2 Semi-rapid burner 1650 W 4 Wok burner 7 Battery housing 8 Control knob for burner 4000 W 11 INSTRUCTIONS FOR THE USER IT IS NECESSARY THAT ALL THE OPERATIONS REGARDING THE INSTALLATION, ADJUSTMENT AND ADAPTATION TO THE TYPE OF GAS AVAILABLE ARE CARRIED OUT BY QUALIFIED PERSONNEL, IN CONFORMITY WITH THE REGULATIONS IN FORCE. THE SPECIFIC INSTRUCTIONS ARE DESCRIBED IN THE BOOKLET SECTION INTENDED FOR THE INSTALLER USING THE BURNERS The symbols silk-screen printed on the side of the knob indicate the correspondence between the knob and the burner. Automatic start-up with valves Turn the corresponding knob anticlockwise up to the maximum position (large flame, fig. 1) and press the knob. [. . . ] Once the burner has been started up, keep the knob pressed for about 6 seconds. Using the burners In order to obtain the maximum yield without waste of gas, it is important that the diameter of the pot is suitable for the burner potential (see the following table), so as to avoid that the flame goes out of the pot bottom (fig. 2). Use the maximum capacity to quickly make the liquids reach the boiling temperature, and the reduced capacity to heat food or maintain boiling. All of the operating positions must be chosen between the maximum and the minimum ones, never between the minimum position and the closing point. The gas supply can be interrupted by turning the knob clockwise up to the closing position. closing position If there is no power supply, it is possible to light the burners with matches, setting the knob to the startup point (large flame). BURNERS Semi-rapid Wok Power W 1650 4000 Ø of pots 16 - 18 cm 24 - 26 cm Notice - When the equipment is not working, always check that the knobs are in the closing position (see fig. 1). - With the models with the safety valve, if the flame should blow out accidentally, the safety valve will automatically stop the gas supply, after a few seconds. To restore operation, set the knob to the lighting point (large flame, fig. 1). - While cooking with fat or oil, pay the utmost attention as these substances can catch fire when overheated. - Do not place unstable or deformed pots on the burner, so as to prevent them from overturning or overflowing. Air must come from permanent openings made on the room walls that communicate with the outside. Gas connection Make sure that the appliance is adjusted for the gas type available (see the label under the appliance). Follow the instructions indicated in the chapter "gas transformations and adjustments" for the possible adaptation to different gases. The appliance must be connected to the gas system by means of stiff metal pipes or flexible steel pipes having continuous walls, in compliance with the regulations in force. Gas enters the appliance through a cylindrical threaded male gas union (1/2"). Once the installation is over, check the connection seal with a soapy solution. Electric connection The appliances without supply cable, does not require to be connected to the mains power supply as it is provided with a low voltage ignition generator supplied by a 1, 5 V battery. 5 15 6 GAS TRANSFORMATIONS AND ADJUSTMENTS Replacing the nozzles If the equipment is adjusted for a type of gas that is different from the one available, it is necessary to replace the burner nozzles. The choice of the nozzles to replace must be made according to the table of the "technical characteristics". - by means of a straight spanner L, unscrew the nozzle U (fig. 7) and substitute it with the corresponding one. Adjusting the burners The lowest flame point must always be properly adjusted and the flame must remain on even if there is an abrupt shift from the maximum to the minimum position. [. . . ] - by means of a straight spanner L, unscrew the nozzle U (fig. 7) and substitute it with the corresponding one. Adjusting the burners The lowest flame point must always be properly adjusted and the flame must remain on even if there is an abrupt shift from the maximum to the minimum position. If this is not so, it is necessary to adjust the lowest flame point as follows: - start the burner up - turn the tap up to the minimum position (small flame) - remove the knob from the tap rod - introduce a flat-tip screwdriver C in the hole F of the tap (fig. 8) and turn the by-pass screw up to a proper adjustment of the lowest flame point. As regards G30 gas burners, the by-pass screw must be tightened completely. 7 8 Replacing the battery (fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SMEG WD5090




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SMEG WD5090 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.