If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TANDBERG MSERIES FC USER. We hope that this TANDBERG MSERIES FC USER user guide will be useful to you.
Manual abstract: user guide TANDBERG MSERIES FC USER
Detailed instructions for use are in the User's Guide.
[. . . ] Tandberg Data FC420 Bridge Option User's Guide
Introduction
3 Fibre Channel Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Library Operation After FC420 Bridge Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cabling the M2500 Library for Fibre Channel
4
One- and Two-Drive Library Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Cabling with Three or More Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The mask is a byte value with the following bit patterns corresponding to the currently supported subsystems: 0x01 FCP Processor /i960 Interaction 0x02 SCSI Processor/i960 Interaction 0x04 Ethernet (Future) 0x20 NVRAM & Flash To display the events from several different subsystems, use a mask value equal to the logical OR of the corresponding subsystem values. To display events from all subsystems enter the value 3Fh for the mask. [event_level] switch: mask that controls what reporting level events are displayed. The mask is a byte value with the following bit patterns corresponding to the currently supported reporting levels: 0x01 Info; general information 0x02 Warning; unexpected situation/condition 0x04 Critical; operation limited/curtailed 0x08 Failure; hard failure 0x10 Other; otherwise not categorized 0x20 Debug; tracking events To display events from several different reporting levels, use a mask value equal to the logical OR of the corresponding reporting levels. To display events for all reporting levels enter the value 3Fh for the mask. [status] switch: has the following two values which correspond to the status of the events to be displayed: all: All events, regardless of their status values are displayed. ngood: Only events with a status other than good are displayed.
DispFcPortDB (Immediate)
0x00
0x00
ngood
Displays the contents of the specified Fibre port's internal database.
dispfcportdb <fp>
FC420 Services Software Commands
15
Tandberg Data FC420 Bridge Option User's Guide Document T6423053-01, Ver. 0 November 2002
Command
DisplayEvent (Immediate)
Description Displays the current contents of the event log. The log is filtered by the current switch settings as described in the DispEvent section. If the optional all is selected, the display filtering is temporarily suspended and all logged events are displayed. The get command displays the statistics; the set command resets the statistic counters to zero. The get command displays the logs; the set command resets the logs to zero.
Default
Syntax displayevent < all >
EccLog
set ecclog clear get ecclog
ErrorLog
set errorlog clear get errorlog
EthernetSpeed
Sets/displays the Ethernet speed of the auto Fibre connection. If auto is selected, the current speed of the connection is indicated in parentheses in the response to the get ethernetspeed command. Specifies whether ACK0 or ACK1 will be returned in response to a Class 2 Fibre Channel data frame or sequence. When enabled, this option sends ACK0; when disabled, this options sends ACK1. Specifies whether the Fibre bridge will support Fibre Channel Class 2 (Multiplexed) or Class 3 service. Sets/displays the connection mode for the FC420 to arbitrated loop or pointto-point. Sets/displays the data rate (in GB/s) at which the Fibre bridge will operate. disabled
set ethernetspeed [10 | 100 |auto] get ethernetspeed
Exit (Immediate)
exit
FcAck0
set fcack0 [enabled | disabled] get fcack0
FcClass2
disabled
set fcclass2 [enabled | disabled] get fcclass2
FcConnMode
loop
set fcconnmode [loop | ptp] get fcconnmode
FcDataRate
auto
set fcdatarate [1gb | 2gb | auto] get fcdatarate
16
FC420 Services Software Commands
Tandberg Data FC420 Bridge Option User's Guide Document T6423053-01, Ver. 0 November 2002
Command
FcFairArb
Description Turns on or off the FC-AL arbitration fairness. Enables/disables full duplex communication between the Fibre bridge and other Fibre Channel devices. Under soft addressing the FC420 loop address is assigned during loop initialization.
Default enabled
Syntax set fcfairarb [enabled | disabled] get fcfairarb
FcFullDuplex
enabled
set fcfullduplex [enabled | disabled] get fcfullduplex
FcHard
disabled
set fchard [enabled | disabled] get fchard
FcHardAddress
Sets/displays the value used as the FC- FC port 0 set fchardaddress [fp [address]] AL hard address. [. . . ] Resets the specified SCSI bus.
Default
Syntax saveconfiguration < restart | nonrestart >
ScsiInitID
0x07
set scsiinitid [sb [0-15]] get scsiinitid [sb]
ScsiPortBusSpeed
ultra3
set scsiportbusspeed [portnumber [fast | ultra | ultra2 | ultra3]] get scsiportbusspeed [portnumber] scsiportlist scsiportreset [sb]
ScsiPortList (Immediate) ScsiPortReset (Immediate)
ScsiPortResetOnStartup Specify whether the SCSI port should
be reset on power-up.
enabled
set scsiportresetonstartup [sb [enabled | disabled]] get scsiportresetonstartup [sb]
ScsiPortSelTimeout
Show the time (msec) that the bridge waits for a response from a SCSI device on the selected port after a selection request. Specify whether synchronous SCSI transfers should be negotiated with devices on the specified SCSI port. Specify whether tagged command queuing is allowed on the SCSI port.
256 msec
set scsiportseltimeout [sb [256 | 128 | 64 | 32 | 16 | 8 | 4 | 2 | 1]] get scsiportseltimeout [sb]
ScsiPortSyncTransfer
enabled
set scsiportsynctransfer [[sb] [enabled | disabled]] get scsiportsynctransfer [sb]
ScsiPortTaggedQueuing
disabled
set scsiporttaggedqueuing [sb [enabled | disabled]] get scsiporttaggedqueuing [sb]
ScsiPortWideTransfer
Specify whether wide SCSI transfers should be negotiated. Set the internal termination of the referenced SCSI port.
enabled
set scsiportwidetransfer [sb [enabled | disabled]] get scsitargets [sb]
ScsiTargets
ScsiTermination
enabled
set scsitermination [sb [enabled | disabled]] get scsitermination [sb]
22
FC420 Services Software Commands
Tandberg Data FC420 Bridge Option User's Guide Document T6423053-01, Ver. [. . . ]