User manual TANDBERG MSERIES INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TANDBERG MSERIES INSTALLATION. We hope that this TANDBERG MSERIES INSTALLATION user guide will be useful to you.


TANDBERG MSERIES INSTALLATION : Download the complete user guide (1890 Ko)

Manual abstract: user guide TANDBERG MSERIES INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Tandberg Data M-Series Installation Guide Introduction Site Requirements 3 3 Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cooling Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Environmental Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Power and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installing a Desktop or Deskside Library 5 Installing a Desktop M1500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installing a Deskside M2500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installing a Rack Mount Library 6 Determining the Position of the Shelves in the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installing the M1500 Rack Mount Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installing the M2500 Rack Mount Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Installing the Library in the Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Installing Drives in the Library 31 Installing Tape Drives in an M1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Installing Tape Drives in an M2500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Preparing and Inserting Tape Cartridges 34 Labeling Tape Cartridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Document T6423046-02 A01, February 2004 1 Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 Setting the Write-Protect Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Placing Cartridges in the Library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Connecting the Library to AC Power 41 M1500 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 M2500 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Connecting the Library to the Host Computer 45 SCSI Cabling Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Terminator Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 SCSI Cabling Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Powering Up the Library Disabling Unused Drive Bays 48 50 2 6207947-04fN 26 Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 Introduction This document explains how to install a stand-alone M1500 or M2500. Note: To install an M1500 or M2500 module in a multiple library stack, refer to the Tandberg StackLink Installation Instructions (PN T6423049). 0 Site Requirements When selecting an installation site for the library, consider the following requirements: · · · · Space Requirements Cooling Considerations Environmental Requirements Power and Grounding 0 Space Requirements 0 Table 1 lists the dimensions of the M1500 and M2500 libraries. Caution: Allow at least 5 inches (12. 7 cm) of space behind the library to allow proper ventilation. Table 1 Library Dimensions M1500 Height Width Depth 6. 9 in. (726 mm) Cooling Considerations 0 Cooling is one of the most important factors to consider when selecting a location for the library. [. . . ] You will need a #2 POZIDRIV® screwdriver for this procedure. Installing an M1500 To install an M1500 in a rack: 1 Take precautions to ensure that the rack is stable: · 0 If you are installing the library at the top of a rack with no equipment at the bottom of the rack, purchase a rack stabilization kit from the rack manufacturer and install it before installing the library. If you are installing the library in a rack with other equipment, place the heaviest equipment at the bottom of the rack. · 2 Verify that the rack mount shelves are level and securely fastened to the rack. At least two people are required to lift and install the library. 3 With the help of another person, lift the library onto the rack mount shelves. 5 Press the button next to the left magazine access door and open the door. 6 Notice the hole behind the magazine access door, at the lower edge of the library (see figure 25). This hole provides access to the rack mount clamp screw. Figure 25 Securing the M1500 to the Rack Magazine access door Access hole for rack mount clamp screw 28 Installing a Rack Mount Library Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 7 Insert a #2 POZIDRIV screwdriver into the hole and turn the rack mount clamp screw clockwise to tighten it. When the screw begins to feel tight, turn it an additional quarter turn and then stop. As you tighten this screw, a lever protrudes from the side of the library and presses against the back side of the rack rail. 8 Repeat steps 5 through 7 to secure the right side of the library to the rack. Proceed to Installing Drives in the Library on page 31 to continue the installation procedure. Installing an M2500 To install an M2500 in a rack: Warning: The M2500 weighs approximately 152 lbs. At least two people are required to lift and install the library. 0 1 Take precautions to ensure that the rack is stable: · If you are installing the library at the top of a rack with no equipment at the bottom of the rack, purchase a rack stabilization kit from the rack manufacturer and install it before installing the library. If you are installing the library in a rack with other equipment, place the heaviest equipment at the bottom of the rack. · 2 Verify that the rack mount shelves are level and securely fastened to the rack. 3 With the help of another person, lift the library onto the rack mount shelves. 5 Press the two buttons next to the left magazine access doors and open the doors. 6 Notice the two holes behind the left magazine access doors (see figure 26). These holes provide access to the rack mount clamp screws. Installing a Rack Mount Library 29 Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 Figure 26 Securing the Library to the Rack Magazine access doors Access holes for the rack mount clamp screws 7 Insert a #2 POZIDRIV screwdriver into one of the holes and turn the rack mount clamp screw clockwise to tighten it fully. When the screw begins to feel tight, turn it an additional quarter turn and then stop. As you tighten this screw, a lever protrudes from the side of the library and presses against the back side of the rack rail. 10 Repeat steps 6 through 8 to secure the right side of the library to the rack. 11 Close the magazine access doors. 30 Installing a Rack Mount Library Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 Installing Drives in the Library This section explains how to install tape drives in the library. You will need the following tools for this procedure: · · · · #2 PHILLIPS® screwdriver (if you are installing drives in an M1500) TORX® T-20 screwdriver (if you are installing drives in an M2500) TORX T-8 screwdriver (if you are installing drives in drive bays 3 through 6 of an M2500) Flat blade screwdriver 0 Installing Tape Drives in an M1500 0 To install tape drives in an M1500: 1 At the back of the library, use a #2 PHILLIPS screwdriver to remove the cover plate protecting the drive bay in which you will install the tape drive. 2 Insert the tape drive into the drive bay slowly until the connectors are seated (see figure 27). 4 Repeat steps 1 through 3 to install another tape drive, if desired. Figure 27 Installing a Tape Drive in an M1500 Tape drive Thumbscrew Installing Drives in the Library 31 Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 Installing Tape Drives in an M2500 0 To install tape drives in an M2500: 1 At the back of the library, use a TORX T-20 screwdriver to remove the cover plate protecting the drive bay in which you will install the tape drive. Note: The cover plates for drive bays 3 through 6 also have a TORX T-8 screw that must be removed to access the drive bay. [. . . ] · Connect all libraries to one AC distribution unit rated minimum 20A, with a minimum 14AWG three wire cord, permanently wired to the electrical supply. 2 3 44 Connecting the Library to AC Power Tandberg Data M-Series Installation Guide Document T6423046-02 A01 February 2004 Connecting the Library to the Host Computer The library robotics and tape drives are independent SCSI devices with independent SCSI connections. The M1500 and M2500 provide two 68-pin high density connectors for each device. You can connect these devices to a single SCSI bus or divide them between two or more SCSI buses. To connect the library or libraries to the host computer(s), refer to the following sections: · · · SCSI Cabling Guidelines Terminator Power SCSI Cabling Diagrams 0 SCSI Cabling Guidelines Refer to these SCSI cabling guidelines when completing the SCSI cabling: 0 · Each device on the SCSI bus must have a unique SCSI ID. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TANDBERG MSERIES INSTALLATION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TANDBERG MSERIES INSTALLATION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.