User manual THOMSON MEC 2 V1.4

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON MEC 2. We hope that this THOMSON MEC 2 user guide will be useful to you.


THOMSON MEC 2 V1.4: Download the complete user guide (538 Ko)

You may also download the following manuals related to this product:

   THOMSON MEC 2 V1.4 (579 ko)

Manual abstract: user guide THOMSON MEC 2V1.4

Detailed instructions for use are in the User's Guide.

[. . . ] MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER (WITH EAP 110 REMOTE ANNUNCIATOR OPTIONS) INSTALLATION, OPERATING & SERVICE MANUAL Software Version 1. 4 PM056 Rev 6 05/10/15 9087A ­ 198th Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER CONTENTS 1. 1. 1. 1. 2. INTRODUCTION PRODUCT REVISION HISTORY GENERAL DESCRIPTION 1 1 3 2. 2. 1. 2. 9. INSTALLATION GENERAL INFORMATION BATTERY SUPPLY INPUT SPEED SENSING INPUT DC VOLTAGE INPUTS AC VOLTAGE INPUT AC CURRENT INPUT OUTPUTS EXTERNAL PANEL CONTROL WIRING REMOTE START CONTACT FIELD WIRING MEC MOUNTING LOCATION/INSTALLATION FACEPLATE MOUNTING DIMENSIONS MEC 2 ASSEMBLY - SIDE VIEW DIELECTRIC TESTING 4 4 4 5 6 6 8 8 8 9 9 10 11 12 2. 10. 3. 2. DESCRIPTION LEXAN FACEPLATE PRINTED CIRCUIT BOARD 13 13 15 PM056 Rev 6 05/10/15 3 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 4. 4. 1. [. . . ] LCD DISPLAY Amps a 408 b 451 c 415 PM056 Rev 6 05/10/15 40 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER Displays generator load current as follows: 3-phase system: PHASE A CURRENT 1-phase system: PHASE A CURRENT Displays generator load current as follows: 3-phase system: PHASE B CURRENT 1-phase system: PHASE B CURRENT Displays generator load current as follows: 3-phase system: PHASE C CURRENT 1-phase system: not applicable 8. 2. 4. 6. GENERATOR FREQUENCY/HOURMETER DISPLAY The generator frequency and operating hours are displayed simultaneously on this screen. LCD DISPLAY FREQ HOURS 60. 1Hz 56783 Hrs Displays generator frequency in hertz (HZ). ENGINE PARAMETER DISPLAY Two engine operating parameter screens are provided as described below. 8. 2. 5. 1. BATTERY VOLTAGE/ENGINE SPEED (tachometer) The battery voltage and engine speed are displayed simultaneously on this screen. LCD DISPLAY BATTERY SPEED 27. 0Vdc 1800rpm PM056 Rev 6 05/10/15 41 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER Displays battery voltage in DC volts. 8. 2. 5. 2. ENGINE TEMPERATURE/OIL PRESSURE The engines operating temperature and oil pressure are displayed simultaneously on this screen. LCD DISPLAY ENG TEMP OIL PRESS 57 Deg C 200 KPA Displays engine temperature in either degrees Celsius or Fahrenheit (as selected). Displays engine oil pressure in either pounds per square inch (PSI) or in Kilopascals (KPA) (as selected). 8. 2. 6. PROGRAM MENU The programming menu is used to access the MEC 2 programmable functions such as time delays, analog fault settings, digital fault settings and calibration. Access to the programming sub-menus may only be obtained with a security password number. The sub menus are organized as follows: PROGRAMMING MENU LCD DISPLAY NO YES PASSWORD PROGRAM MENU?NO Displays two messages that may be toggled between YES and NO by pressing the INCREMENT pushbutton. Their functions are described as follows: NO YES Programming sub-menus are disabled when NO is displayed. Programming sub-menus are enabled when YES is displayed and a valid password number is entered. PM056 Rev 6 05/10/15 42 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 8. 3. SEQUENCE OF OPERATION 8. 3. 1. GENERAL The MEC 2 Engine-generator controller is designed to start and stop an engine from either a local ("manual") or remote ("automatic") command. When this command is issued, the controller issues a run and crank output signal. The controller then monitors engine speed and when crank disconnect speed is reached, the crank signal is terminated. While the engine accelerates to normal speed, the controller continuously monitors the engines speed signal. Should the engine speed exceed the maximum predetermined setpoint, the over speed shutdown fault circuit will activate, terminating the run signal. In addition to over speed shutdown, the engine controller also monitors many other engine protection circuits and should they be activated, the engine will be stopped and/or alarm initiated. The engine will automatically stop for any shutdown condition, or when the remote and/or local start signal is removed. The engine controller operation includes time delay circuits for normal operating conditions such as start delays, cooldown and cranking periods. 8. 3. 2. MANUAL START/STOP SEQUENCE When the "RUN" pushbutton on the front faceplate keypad is pressed, an ENGINE START DELAY timer will be initiated. [. . . ] CALIBRATION MENU CALIBRATION MENU VOLTS ZERO XXX VOLTS SPAN XXX VOLTS ZERO XXX A-B XXXVAC A-B XXXVAC B-C XXXVAC PM056 Rev 6 05/10/15 77 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER CALIBRATION MENU VOLTS SPAN XXX VOLTS ZERO XXX VOLTS SPAN XXX VOLTS ZERO XXX VOLTS ZERO XXX VOLTS ZERO XXX VOLTS ZERO XXX VOLTS ZERO XXX VOLTS ZERO XXX CURRENT ZERO XXX CURRENT SPAN XXX CURRENT ZERO XXX CURRENT SPAN XXX CURRENT B XXXAAC C B-C XXXVAC C-A XXXVAC C-A XXXVAC A-N XXXVAC A-N XXXVAC B-N XXXVAC B-N XXXVAC C-N XXXVAC C-N XXXVAC A XXXAAC A XXXAAC B XXXAAC PM056 Rev 6 05/10/15 78 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER CALIBRATION MENU ZERO XXX CURRENT SPAN XXX XXXAAC C XXXAAC BATTERY VOLTAGE SPAN XXX XX. X VDC ENGINE TEMPERATURE XXX XXX C/F OIL PRESSURE XXX XXXX PSI/KPA PM056 Rev 6 05/10/15 79 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 12. · · SPECIFICATIONS 10 to 30Vdc, negative ground -15°C to +50°C1 Power supply: Operating temperature: 1 Extended temperature ratings are available using the VFD display option. Extended ratings are: Operating -40°C to +85°C, Storage -50°C to +85°C NEMA 1 4g, 5-250Hz 5 watts (max. ) -20°C to +70°C1 5 to 95% non-condensing 10. 75"W x 6. 75"H x 2. 0"D ± 1. 0%, @ 25°C Volts, Amps ± 2% @25°C KVA Inputs: Engine Speed Sensing AC Voltage AC Current Engine Parameters Digital Fault Contacts 100 - 10, 000Hz, 3. 0 - 20VAC, rms 120 - 600VAC (nominal), 0. 1VA, 3 phase, 50/60Hz 0 - 5Aac (nominal), 1. 5VA, 3 phase Dedicated Senders (supplied loose) Open or close to DC Negative 10A/240VAC, 8A/24Vdc resistive (3A inductive, 0. 4pf), Form A 10A/240VAC, 8A/24Vdc resistive (3A inductive, 0. 4pf), Form A · · · · · · · · Environmental (Faceplate): Vibration: Power consumption: Storage temperature: Humidity: Dimensions: AC Metering Accuracy: · Output contacts: Run, Crank Programmable · Analog Oil Pressure Measurement: Range: 15 PSI ­ 150 PSI (maximum) Pressure Accuracy Operating range 15 - 59 PSI = +-6 PSI Operating range 60 - 75 PSI = +-2 PSI Operating range 76-150 PSI = +-7 PSI · Analog Engine Temperature Measurement: Range: 0-200°C (maximum) Operating range 0 - 30°C = +-8°C Operating range 30 -100°C = +-2°C Operating range 100 -200°C = +-8°C Specifications subject to change without notice. Temperature Accuracy PM056 Rev 6 05/10/15 80 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 13. CONNECTION DIAGRAM 12/24Vdc BATTERY ­ + 10A 1A B+ B­ 7 GRD VA 1A VB 1A VC VA VB VC N GENERATOR OUTPUT VOLTAGE 120Vac TO 600Vac 3 PHASE OR SINGLE PHASE 4 (DELETE PHASE VC FOR SINGLE PHASE SYSTEM S) 5 GRD 23 CRANK 1 6 CRANK PILOT RELAY CR 24 18 VN IA 6 RUN CIRCUIT RUN CIRCUIT (FUEL SOL. , GOV. ) RUN 19 M P1 M P2 G RD 1 ØA ØB ØC IB 6 SPEED SENSING M AGNETIC PICKUP M EC 2 IC IN GRD GENERATOR OUTPUT CURRENT SENSING TRANSFORMERS 5 Aac SECONDARY (DELETE PHASE C FOR SINGLE PHASE SYSTEM S) 2 2 6 6 OIL PRESSURE SENDER ENGINE TEM PERATURE SENDER 37 38 13 14 15 REM OTE EM ERGENCY STOP (CLOSE TO INITIATE) REM OTE FAULT RESET (CLOSE TO INITIATE) REM OTE START CONTACT 6 3 28 16 17 1 2 3 4 33 34 1 1 1 29 30 31 32 PROGRAM M ABLE CONTACT #1 DIGITAL FAULT INPUT CONTACTS #1 TO #4 PROGRAM M ABLE CONTACT #2 35 36 22 PROGRAM M ABLE CONTACT #3 1 21 20 PROGRAM M ABLE CONTACT #4 N O TE S : 1 2 CONTACTS RATED M AXIM UM 10A, 240Vac, 8A, 24Vdc RESISTIVE SENDER INPUTS M AY BE PROGRAM M ED FOR ALARM AND/OR SHUTDOW N CONDITIONS OF LOW OIL PRESSURE OR HIGH ENGINE TEM PERATURE LOGIC IS SOFTW ARE PROGRAM M ABLE FOR OPEN OR CLOSE ON FAIL GENERATOR SUPPLY M UST UTILIZE A SOLIDLY GROUNDED NEUTRAL SYSTEM ­ REFER TO INSTRUCTION M ANUAL FOR ALTERNATE CONNECTIONS NEUTRAL CONNECTION IS REQUIRED FOR DISPLAY ON PHASE TO NEUTRAL VOLTAGES ENGINE M OUNTED COM PONENTS "GRD" CONNECTION TO BE M ADE TO COM M ON CHASSIS/ENCLOSURE GROUND BOND SYSTEM G :\ENG INEER\PRO DUCTS\M EC2M EC2_04. VSD REV 4 02/01/24 3 4 5 6 7 PM056 Rev 6 05/10/15 81 Thomson Technology MEC 2 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 14. TROUBLE SHOOTING A number of problems can cause the MEC 2 controller not to function properly. Consult the factory for any detailed information or for any problems not listed. CAUTION!!! Before opening the enclosure to perform any service task, it is imperative to isolate the control system from any possible source of power. Failure to do so may result in serious personal injury or death due to electrical shock. Service procedures must be undertaken by qualified personnel only! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON MEC 2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON MEC 2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.