User manual THOMSON MEC 20 V1.82

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON MEC 20. We hope that this THOMSON MEC 20 user guide will be useful to you.


THOMSON MEC 20 V1.82: Download the complete user guide (589 Ko)

You may also download the following manuals related to this product:

   THOMSON MEC 20 V1.82 (644 ko)
   THOMSON MEC 20 V1.82 (599 ko)

Manual abstract: user guide THOMSON MEC 20V1.82

Detailed instructions for use are in the User's Guide.

[. . . ] MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER (WITH REMOTE COMMUNICATION, EXPANSION OUTPUT MODULE & EAP 110 REMOTE ANNUNCIATOR OPTIONS) INSTALLATION, OPERATING & SERVICE MANUAL Software Version 1. 82 PM047 Rev 13 05/03/30 9087A ­ 198th Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER CONTENTS 1. 1. 1. 1. 2. INTRODUCTION PRODUCT REVISION HISTORY GENERAL DESCRIPTION 1 1 3 2. 2. 1. 2. 9. INSTALLATION GENERAL INFORMATION BATTERY SUPPLY INPUT SPEED SENSING INPUT DC VOLTAGE INPUTS AC VOLTAGE INPUT AC CURRENT INPUT OUTPUTS EXTERNAL PANEL CONTROL WIRING REMOTE START CONTACT FIELD WIRING REMOTE COMMUNICATION WIRING EXPANSION OUTPUT MODULE LOCATION/INSTALLATION MEC MOUNTING LOCATION/INSTALLATION FACEPLATE MOUNTING DIMENSIONS MEC 20 ASSEMBLY - SIDE VIEW DIELECTRIC TESTING 5 5 5 6 6 7 8 8 8 9 9 10 11 11 13 14 2. 10. 2. 15. 3. DESCRIPTION 14 PM047 Rev 12 03/03/04 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 3. 1. [. . . ] The Utility Read to Load programmable output will energize if the remote start contact is open. 9. 2. MEC 20 DISPLAY MENUS The MEC 20 contains a Liquid Crystal Display (LCD) which is visible through the front lexan faceplate viewing window. The LCD has pre-programmed display screens and menus that may be selected by pressing the ENTER or EXIT push-buttons in succession until the desired screen or menu is displayed. The display screen types and order in which they are programmed are as follows: PM047 Rev 13 05/03/30 41 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER OPERATING STATUS TIMER COUNTDOWN FAULT DISPLAY GENERATOR METERING (Average) GENERATOR PHASE VOLTAGES GENERATOR LINE TO NEUTRAL VOLTAGES GENERATOR PHASE CURRENTS GENERATOR KVA GENERATOR FREQUENCY/HOURMETER BATTERY VOLTAGE/ENGINE SPEED (TACH) ENGINE TEMPERATURE/OIL PRESSURE PROGRAM MENU FAULT DISPLAY (Multiple Faults) 9. 2. 1. OPERATING STATUS MENU The operating status menu provides the operator with detailed information as to the status of the engine-generator set. NOTE: The operating status screen may be momentarily replaced with a time delay countdown screen when a start or stop sequence is initiated. The display will automatically return to the previous menu following expiry of the timing sequence. PM047 Rev 13 05/03/30 42 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER The operating status sub-menus are organized as follows: OPERATING STATUS UNIT READY SWITCH IN OFF UNIT RUNNING UNIT SHUTDOWN UNIT ALARM 9. 2. 1. 1. UNIT READY This indicates that the controller is in "Auto" position and there are no active shutdowns or alarms. 9. 2. 1. 2. SWITCH IN OFF This indicates that the controller has been selected to the "off" position from the front panel keypad push-button. 9. 2. 1. 3. UNIT RUNNING This indicates that the engine is running and all conditions are normal. 9. 2. 1. 4. UNIT SHUTDOWN This indicates that a shutdown fault is active. The specific fault condition will be automatically displayed. 9. 2. 1. 5. UNIT ALARM This indicates that one or more alarm fault circuits are active The display will automatically scroll through all active faults at a rate of every two seconds. 9. 2. 2. FAULT DISPLAY MENU The fault display menu is automatically displayed when either an alarm or shutdown circuit is activated. The specific alarm or shutdown fault label will be displayed and if multiple alarm conditions are present, the display will automatically scroll through all active faults. 9. 2. 3. TIMER COUNTDOWN MENUS Timer countdown menus are automatically displayed when a specific time delay function occurs during a control sequence. When a time delay begins, the LCD display will indicate the time delay function name (i. e. ENGINE START DELAY) PM047 Rev 13 05/03/30 43 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER and the current time remaining in the countdown sequence. When the timing function has expired, the LCD display will automatically change to either the next timing sequence countdown display or return to the original system status menu. LCD DISPLAY ENGINE START DELAY 45 SEC Displays specific time delay function currently in operation Displays current time in seconds or minutes that are left in the specific timing sequence. NOTE: During a timer countdown sequence, a different display screen may be selected by pressing the "ENTER" push-button. The following timer countdown screens are provided: ENG START DELAY CRANK PERIOD REST PERIOD STARTER RE-ENGAGE DELAY BYPASS DELAY COOLDOWN DELAY WARMUP DELAY* RETURN DELAY* NEUTRAL DELAY* programmed. XX SEC. ** Countdown screens only appear if Utility Gen Ready to Load outputs are 9. 2. 4. GENERATOR AC METERING Four generator AC metering screens are provided as described below. 9. 2. 4. 1. AVERAGE DISPLAY VOLTAGE/CURRENT & FREQUENCY The generator average voltage/current & frequency metering screen allows the operator to simultaneously view all the listed parameters. PM047 Rev 13 05/03/30 44 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER LCD DISPLAY Vavg 432 Aavg 60. 1 Freq 600 Displays the average generator voltage as follows: 3-phase system: AVERAGE LINE TO LINE VOLTAGE--Phases AB, BC, CA 1-phase system: LINE TO LINE VOLTAGE--Phases A to B Displays 3-phase the system: average AVERAGE generator LINE current as follows: A, B, C CURRENT--Phases 1-phase system: AVERAGE LINE CURRENT--Phases A, B Displays generator frequency in hertz (HZ). GENERATOR KVA DISPLAY The generator's total power output in kilo-voltamperes (KVA) is displayed. GENERATOR PHASE VOLTAGE DISPLAY (LINE TO LINE) The generator phase voltage screen allows the operator to view the generator AC voltage on all 3 phases (or single phase system as selected). LCD DISPLAY Vab Vbc 600 Vca 600 600 PM047 Rev 13 05/03/30 45 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER Displays generator voltage as follows: 3-phase system: LINE TO LINE VOLTAGE--Phases A to B 1-phase system: LINE TO LINE VOLTAGE--Phases A to B Displays generator voltage as follows: 3-phase system: LINE TO LINE VOLTAGE--Phases B to C 1-phase system: LINE TO NEUTRAL VOLTAGE--Phases A-N Displays generator voltage as follows: 3-phase system: LINE TO LINE VOLTAGE--Phases C-A 1-phase system: LINE TO NEUTRAL VOLTAGE--Phases B-N 9. 2. 4. 4. GENERATOR PHASE/NEUTRAL VOLTAGE DISPLAY (LINE TO NEUTRAL) The generator phase/neutral display allows the operator to view the generator line to neutral voltage for all 3 phases of the system. Note: The generators neutral must be connected to MEC 20 terminal TB1-VN and the "neutral connected" prompt in the main program menu must be selected as "Yes". LCD DISPLAY Van 347 Vbn 347 Vcn 347 Displays generator voltage Phase A to Neutral. GENERATOR PHASE CURRENT DISPLAY The generator phase current screen allows the operator to view the generator load current on all 3 phases (or single phase system as selected). [. . . ] DIGITAL FAULT PROGRAMMING MENU TYPICAL PROGRAM FACTORY DEFAULT SETTINGS DIGITAL FAULT PROGRAMMING MENU FAULT NAME INPUT # ACTION S=SHUTDOWN A=ALARM ALARM LATCH Y=YES N=NO POLARITY O=OPEN C=CLOSE BYPASS ON START Y=YES N=NO TRANSIENT DELAY (SEC) LOW OIL PRESSURE HIGH ENG TEMP BATT CHGR INPUT FAIL LOW FUEL LEVEL "blank" "blank" "blank" "blank" "blank" "blank" REMOTE EMERG STOP IDLE 1 2 3 4 5 6 7 8 9 10 11 S S A A A A A A A A S __ __ Y N N N N N N N N O O C C C C C C C C C Y Y N N N N N N N N N 0. 5 1. 0 30. 0 0. 1 0. 0 0. 0 0. 0 0. 0 0. 0 0. 0 0. 1 12 A N C N 0. 1 PM047 Rev 13 05/03/30 85 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 11. 5. CALIBRATION MENU CALIBRATION MENU VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS VOLTS CURRENT CURRENT CURRENT CURRENT CURRENT CURRENT A-B A-B B-C B-C C-A C-A A-N A-N B-N B-N C-N C-N A A B B C C ZERO SPAN ZERO SPAN ZERO SPAN ZERO SPAN ZERO SPAN ZERO SPAN ZERO SPAN ZERO SPAN ZERO SPAN SPAN XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX C/F XXXX PSI/KPA XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC XXXVAC BATTERY VOLTAGE ENGINE TEMPERATURE OIL PRESSURE PM047 Rev 13 05/03/30 86 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 12. · · 1 SPECIFICATIONS 10 to 30Vdc, negative ground -15°C to +50°C1 Extended ratings are: Power supply: Operating temperature: Extended temperature ratings are available using the VFD display option. Operating -40°C to +70°C, Storage -50°C to +85°C · · · · · · · · Environmental (Faceplate): Vibration: Power consumption: Storage temperature: Humidity: Dimensions: AC Metering Accuracy: Inputs: Engine Speed Sensing AC Voltage AC Current Engine Parameters Digital Fault Contacts · Output contacts: Run, Crank Programmable · Analog Oil Pressure Measurement: Range: 15 PSI ­ 150 PSI (maximum) Pressure Accuracy NEMA 12 4g, 5-250Hz 5 watts (max. ) -20°C to +70°C1 5 to 95% non-condensing 10. 75"W x 6. 75"H x 2. 0"D ± 1. 0%, @ 25°C Volts, Amps ± 2% @25°C KVA 100 - 10, 000Hz, 3. 0 - 20Vac, rms 120 - 600Vac (nominal), 0. 1VA, 3 phase, 50/60Hz 0 - 5Aac (nominal), 1. 5VA, 3 phase Dedicated Senders (supplied loose) Open or close to DC Negative 10A/240Vac, 8A/24Vdc resistive (3A inductive, 0. 4pf), Form A 10A/240Vac, 8A/24Vdc resistive (3A inductive, 0. 4pf), Form A Operating range 15 - 59 PSI = +-6 PSI Operating range 60 - 75 PSI = +-2 PSI Operating range 76-150 PSI = +-7 PSI · Analog Engine Temperature Measurement: Range: 0-200°C (maximum) Temperature Accuracy Operating range 0 - 30°C = +-8°C Operating range 30 -100°C = +-2°C Operating range 100 -200°C = +-8°C Specifications subject to change without notice. PM047 Rev 13 05/03/30 87 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 13. CONNECTION DIAGRAM GRD 12/24Vdc BATTERY ­ + 10A 1A B+ B­ 5 VA VB VC 1A 1A VA VB VC N GRD 23 CRANK 24 18 RUN 19 MP1 MP2 1 1 4 CRANK PILOT RELAY CR VN IA IB GENERATOR OUTPUT VOLTAGE 120Vac TO 600Vac 3 PHASE OR SINGLE PHASE 3 (DELETE PHASE VC FOR SINGLE PHASE SYSTEMS) 4 4 RUN CIRCUIT (FUEL SOL. , GOV. ) RUN CIRCUIT ØA ØB ØC GRD SPEED SENSING MAGNETIC PICKUP GRD MEC 20 IC IN 25 GENERATOR OUTPUT CURRENT SENSING TRANSFORMERS 5 Aac SECONDARY (DELETE PHASE C FOR SINGLE PHASE SYSTEMS) 4 4 OIL PRESSURE SENDER ENGINE TEMPERATURE SENDER 37 38 13 14 15 1 REMOTE EMERGENCY STOP (CLOSE TO INITIATE) REMOTE FAULT RESET (CLOSE TO INITIATE) REMOTE START CONTACT 4 2 26 27 28 COMMON FAIL CONTACT (OPERATES ON AN ALARM OR SHUTDOWN CONDITION) 16 17 1 2 3 4 5 6 7 8 9 10 11 12 1 1 1 1 29 30 31 32 33 34 24 35 36 22 21 20 PROGRAMMABLE CONTACT #1 DIGITAL FAULT INPUT CONTACTS #1 TO #12 PROGRAMMABLE CONTACT #2 PROGRAMMABLE CONTACT #3 PROGRAMMABLE CONTACT #4 NOTES: 1 2 3 CONTACTS RATED MAXIMUM 10A/240Vac, 8A/24Vdc RESISTIVE LOGIC IS SOFTWARE PROGRAMMABLE FOR OPEN OR CLOSE ON FAIL GENERATOR SUPPLY MUST UTILIZE A SOLIDLY GROUNDED NEUTRAL SYSTEM ­ REFER TO INSTRUCTION MANUAL FOR ALTERNATE CONNECTIONS ENGINE MOUNTED COMPONENTS "GRD" CONNECTION TO BE MADE TO COMMON CHASSIS/ENCLOSURE GROUND BOND SYSTEM 4 5 G:\ENGINEER\PRODUCTS\MEC20_04. VSD REV 3 02/02/20 PM047 Rev 13 05/03/30 88 Thomson Technology MEC 20 MICROPROCESSOR ENGINE/GENERATOR CONTROLLER 14. TROUBLE SHOOTING A number of problems can cause the MEC 20 controller not to function properly. Consult the factory for any detailed information or for any problems not listed. CAUTION!!! Before opening the enclosure to perform any service task, it is imperative to isolate the control system from any possible source of power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON MEC 20




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON MEC 20 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.