User manual THOMSON TSC 80E V2.1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual THOMSON TSC 80E. We hope that this THOMSON TSC 80E user guide will be useful to you.


THOMSON TSC 80E V2.1: Download the complete user guide (1873 Ko)

You may also download the following manuals related to this product:

   THOMSON TSC 80E V2.2 (1738 ko)
   THOMSON TSC 80E V2.2 (1873 ko)

Manual abstract: user guide THOMSON TSC 80EV2.1

Detailed instructions for use are in the User's Guide.

[. . . ] TSC 80e TRANSFER SWITCH CONTROLLER INSTALLATION, OPERATING & SERVICE MANUAL Software Version 2. 1 PM091 Rev 0 09/01/21 9087A ­ 198 Street, Langley, BC Canada V1M 3B1 Telephone (604) 888-0110 Telefax (604) 888-3381 E-Mail: info@thomsontechnology. com www. thomsontechnology. com th TSC 80e TRANSFER SWITCH CONTROLLER TABLE OF CONTENTS 1. SYSTEM VOLTAGE SYSTEM PHASING - HIGH LEG DELTA SYSTEMS REMOTE START CONTACT FIELD WIRING DIELECTRIC TESTING 1 1 2 2 2 3 4 4 2. DESCRIPTION 2. 1. UTILITY POWER FAIL SIMULATION (LOAD TEST) AUTOMATIC PLANT EXERCISE TEST FOUR FUNCTION REMOTE TEST (FTS4 OPTION) REMOTE TEST 17 17 18 19 20 3. 3. SYSTEM STATISTICS PM091 Rev 0 09/01/21 20 21 21 22 22 25 25 Thomson Technology TSC 80e TRANSFER SWITCH CONTROLLER 3. 6. 4. [. . . ] 3. 6. 1. 15. GENERATOR MODE STATUS The LCD screen displays the present operating mode the generator is in. 3. 6. 1. 16. UTILITY FAULT STATUS The LCD screen displays the current status of the Utility Supply. The following statuses can be displayed: Normal Utility Limit Switch Fail Utility Switching Device Failed PM091 Rev 0 09/01/21 24 Thomson Technology TSC 80e TRANSFER SWITCH CONTROLLER 3. 6. 1. 17. GENERATOR FAULT STATUS The LCD screen displays the current status of the Generator Supply. The following statuses can be displayed: Normal Gen Limit Switch Fail Gen Switching Device Failed 3. 6. 2. LCD DISPLAY MODE OPERATION The Lexan faceplate Up & Down arrow pushbuttons can be used for control or navigation of the LCD screens as follows: LCD Display Auto Scroll Halt: The automatic scrolling feature can be halted by pressing and holding the DOWN arrow pushbutton for approximately 2 seconds (2 LED flashes). The display will remain at the screen that was displayed when the pushbutton was activated for 255 seconds, and then it will return to the auto scroll mode. Manual Advance & Lock-on to Next LCD Display Screen: To manually advance the LCD to the next screen, press and hold the DOWN arrow pushbutton for approximately 1 second until the screen changes. Note: The LCD display will return to the automatic scrolling mode in 255 seconds if no other pushbuttons are used. Note: For quick advancement to the next display screen, momentarily press the DOWN arrow pushbutton until the screen changes. Manual Return & Lock-on to Previous LCD Display Screen: To manually return to the previous LCD screen, press and hold the UP arrow pushbutton for approximately 1 second until the screen changes. Note: The LCD display will return to the automatic scrolling mode in 255 seconds if no other pushbuttons are used. Note: For quick advancement to the previous display screen, momentarily press the UP arrow pushbutton until the screen changes. 3. 6. 3. SYSTEM STATISTICS The SYSTEM STATISTICS menu displays the following events: o Total Number of Transfers PM091 Rev 0 09/01/21 25 Thomson Technology TSC 80e TRANSFER SWITCH CONTROLLER o o o o Number of Hours Controller is energized Number of Hours Load is on Generator Number of Hours Load is on Utility Total Number of Transfers due to source failure Hours Max = 65, 535 Hours 59 Minutes 59 seconds for Load on Gen Hours Max = 65, 535 Hours 59 Minutes 59 seconds for Load on Util Total Transfers = 65, 535 The TSC 80e has the maximum number of events memory as follows: o o o o Maximum Logged Events = 32 - Ring buffer 3. 6. 4. DATALOG MENU The DATALOG menu displays the recorded data logging for the following events: The TSC 80e will record the following data, and will time/date stamp when the event occurred. System Power On DST Activated DST De-Activated Load on Gen Load on Util Black Start Util Black Start Gen Data Log Cleared Fault on Util Xfr Fault: Util Limit Fault: Util Switch Fault on Gen Xfr Fault: Gen Limit Fault: Gen Switch Fault Reset For Each phase (A, B, C) of Gen and Utility; Under Voltage, Over Voltage, Under Frequency, Over Frequency Gen Test Start Gen Test Stop Util Test Start Util Test Stop PM091 Rev 0 09/01/21 26 Thomson Technology TSC 80e TRANSFER SWITCH CONTROLLER 4. TSC 80e SOFTWARE PROGRAMMING INSTRUCTIONS 4. 1. PASSWORDS Access to the programmable parameters of the TSC 80e Transfer Controller is via a security password number. Two levels of security passwords are provided as described below: 4. 1. 1. USER READ (VIEW ONLY MODE) User can view any programming parameter as required. To enter the VIEW ONLY MODE to review programming settings, follow the procedure as listed below: 1. Press the DOWN or UP keys to scroll through the available programming menus. Once the selected program menu is displayed, press the ENTER key to view the sub-menus available. Press the DOWN or UP keys to scroll through the programming sub-menus available. Once the selected program sub-menu item is displayed, press the ENTER key to view the selected value. [. . . ] MAX. 24 SYSTEM GROUND 28 ENGINE START CONTACT (Contact closes to start engine on power failure) RATED 10A, 120/250VAC, 5A, 30VDC RES. MAX. A (L1) 27 1 34 UTILITY SUPPLY SENSING 120-600VAC 50/60Hz 3 PHASE 1 B (L2) 2 33 PROG #3 FAIL TO TRANSFER (DEFAULT) RATED 10A, 120/250VAC, 5A, 30VDC RES. MAX. C (L3) 3 32 37 A (L1) 4 36 PROG #2 LOAD DISCONNECT CONTACT (DEFAULT) RATED 10A, 120/250VAC, 5A, 30VDC RES. MAX. GENERATOR SUPPLY SENSING 120-600VAC 50/60Hz 3 PHASE 1 35 B (L2) 5 31 C (L3) 6 30 PROG #1 ATS NOT IN AUTO (DEFAULT) RATED 10A, 120/250VAC, 5A, 30VDC RES. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE THOMSON TSC 80E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual THOMSON TSC 80E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.