User manual VISONIC DISCOVERY K9-80 MCW INSTALLER GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VISONIC DISCOVERY K9-80 MCW. We hope that this VISONIC DISCOVERY K9-80 MCW user guide will be useful to you.


VISONIC DISCOVERY K9-80 MCW INSTALLER GUIDE: Download the complete user guide (446 Ko)

Manual abstract: user guide VISONIC DISCOVERY K9-80 MCWINSTALLER GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Transmit Current Drain: 20mA (including LED) Coverage Pattern Battery Life Expectancy (with LED jumper in ON position): Typically over 3 years (regular version); 2 years (DD243 version). Battery Supervision: Automatic reporting of battery status with each alarm and with periodic supervision message. FUNCTIONAL True Motion Event Verification: 2 position selector - 1 (OFF) or 2 (ON) motion events. Alarm Period: 3 seconds Visual Indications: LED lights for about 3 seconds upon transmission of alarm & tamper messages and upon each motion detection in the walk test mode. [. . . ] Loosen the vertical adjustment screw, slide the PCB down and remove it via the "keyhole" (see Figure 4). Rotate the bracket to the desired position (see Figure 7) but do not yet tighten the screw fully. 2 DE3638 Note: At power up or reset, the LED flashes for 30 seconds regardless of the jumper position and then enters walk-test mode. After 15 minutes the detector enters normal mode in which the LED functions according to the LED control jumper position. 3. 8 Vertical Adjustment Figure 7. Mark the points for drilling through the two mounting holes of the bracket. Pet-Immune Applications To maintain maximum coverage range and pet immunity, the vertical adjustment scale must be adjusted in accordance with the actual mounting height (refer to Figure 10). Loosen the vertical adjustment screw and slide the printed circuit board up or down until the pointer shows the actual mounting height on the scale. Pet-Free Locations To obtain the best coverage possible where no pets are present, mount the detector with the integral bracket at any desired height between 1. 8 m (6 ft) and 2. 4 m (8 ft). Then set the vertical adjustment scale to the 2. 4 m (8 ft) position and tilt the detector 20° down. Figure 8. Tilt/Swivel Limits 3. 6 Setting the Motion Event Counter The location of the motion event jumper is shown in Figure 4. Refer to Figure 9 below and mount the jumper as desired. 3. 9 Walk Testing Figure 9. Motion Event Counter Setting Options 3. 7 Setting the LED Control Jumper ON Position: Setting the jumper as shown enables the LED. Remember that the detector disables itself for 2-minutes after detection!OFF Position: Setting the jumper as shown disables the LED. Upon battery insertion or closing of the cover (which results in closing of the tamper switch) the detector goes into walk-test mode and automatically exits the mode after 15 minutes. This results in the resetting of the detector and the start of walktest mode. Walk-test the entire protected area by walking slowly across the detector's field of view, observing the LED. Pause for 5 seconds after each detection to allow the detector to complete its 3transmission sequence; the LED will light for about 3 seconds. When the walk-test is completed (after 15 minutes), the detector's setting automatically changes according to the LED control jumper setting. The OFF setting is recommended to prevent unauthorized people from tracing the detector's coverage pattern. If the LED is disabled, you may use the control panel's visual and audible indicators to verify proper function of the detector. To assure proper function of the detector, the range and coverage area should be checked at least twice a year. Furthermore, the user should be instructed to perform a walk test at the far end of the coverage pattern to assure an alarm signal prior to each time the alarm system is armed. 4. However, due to their low transmitting power and limited range (required by FCC and other regulatory authorities), there are some limitations to be considered: A. [. . . ] Any provision in this warranty which is contrary to the Law in the state or country were the Product is supplied shall not apply. Warning: The user must follow the Manufacturer's installation and operational instructions including testing the Product and its whole system at least once a week and to take all necessary precautions for his/her safety and the protection of his/her property. Product Recycling Declaration For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC DISCOVERY K9-80 MCW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VISONIC DISCOVERY K9-80 MCW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.