User manual WHIRLPOOL HV303 INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL HV303. We hope that this WHIRLPOOL HV303 user guide will be useful to you.


WHIRLPOOL HV303 INSTALLATION: Download the complete user guide (329 Ko)

Manual abstract: user guide WHIRLPOOL HV303INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent backdrafting manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Do not install this product with the activating switch directly behind a burner or element. Minimum distance between the switch and the edge of the burner should be 4 inches. [. . . ] Plan to provide a grounded outlet in a location which will allow the unit's power cord to reach. (Note: If the Model HV303 is being installed in a 30" wide cabinet or the Model HV363 is being installed in a 36" wide cabinet, the outlet cannot be located on the back wall of cabinet. ) Outlet may also be wallmounted, with access hole in cabinet. 2 PREPARATION CHANGING BLOWER DISCHARGE (Optional) The blower is shipped with its discharge facing DOWN. Lay out and cut the cooktop cut-out far enough FORWARD so downdraft will fit behind it. Center and square it with edges of countertop. · · the position of the blower discharge needs to be moved so ductwork does not interfere with floor joists, plumbing or wiring below. it is necessary to rotate the blower discharge to the RIGHT or LEFT. Place the unit on its back on a table or work surface. DOWN DISCHARGE - MOVING BLOWER LEFT OR RIGHT NUTS CLAMP CHANNEL BLOWER SHEET METAL SCREW 3. Place the plastic template against the back flange of the cooktop and center it. Tighten nuts to secure top of blower and use sheet metal screws through bottom flange to secure bottom of blower. BOTTOM FLANGE 5. Be careful not to chip edges of countertop. MOUNT THE UNIT MOUNTING SCREWS LEVELING BRACKET FLANGE FACING OUT LEFT OR RIGHT DISCHARGE BLOWER NUT CLAMP CHANNEL MOTOR PLUG SHEET METAL SCREW LEVELING BRACKET FLANGE FACING IN COVER PLATE 1. Replace clamp channels and use nuts to secure the blower in its new position. Use sheet metal screws through bottom flange to secure bottom of blower. 1. Extend leveling brackets to floor of cabinet so downdraft sits straight. (Note: Leveling brackets can be removed and re-attached in other positions. Bottom flange may have to face inward in tight cabinet installations. ) 2. Secure the downdraft to the countertop as follows: Hold the downdraft against the back of countertop cut-out and tightening the 2 mounting screws (one on each end of unit) on underside of countertop. Use a wood shim between screw and underside of granite countertops. 3 3. Tighten screws holding leveling bracket to unit on each side. INSTALL DUCTWORK CAUTION - BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK: Check for interference with floor joists, wall studs, electrical wiring or plumbing. WIRING DIAGRAM BLOWER 3-1/4" X 10" TO 6" RD. Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered. There should be a gap of 1/32"-1/16" between the back of the cooktop and the front of the downdraft cover. 1. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Note: A 3-1/4" x 10" collar is provided for installers who prefer to rivet the ductwork to the unit. [. . . ] IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW. MAYTAG CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS, SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY STATE TO STATE OR PROVINCE TO PROVINCE. If You Need Service First see the Troubleshooting section in your Use and Care Guide or call the dealer from whom your appliance was purchased or call Maytag Services, LLC, Customer Assistance at 1-800-688-9900 USA and 1-800-688-2002 Canada to locate an authorized servicer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL HV303




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL HV303 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.