User manual WHIRLPOOL WRF535SWBB DIMENSION GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WRF535SWBB. We hope that this WHIRLPOOL WRF535SWBB user guide will be useful to you.


WHIRLPOOL WRF535SWBB DIMENSION GUIDE: Download the complete user guide (156 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WRF535SWBB ENERGY GUIDE (117 ko)
   WHIRLPOOL WRF535SWBB USE & CARE GUIDE (1539 ko)
   WHIRLPOOL WRF535SWBB WARRANTY INFORMATION (93 ko)

Manual abstract: user guide WHIRLPOOL WRF535SWBBDIMENSION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Fuse Size 15 28. 56 X 18 X 20. 5 The finish is stainless steel with a galvanized back panel. Minimum circuit ampacity is used to determine wire size per national electric code. OPERATING REQUIREMENTS: MINIMUM MAXIMUM Air Temperature Water Temperature Water Pressure Voltage 500 F. 100 PSIG 126. 5V Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. [. . . ] After about 20 minutes the machine will begin to release the ice, this is called the harvest cycle. Observe the first cube harvest: ·Ice making spray nozzles. ·Check the size of the ice cubes. Note: The normal size of the ice cube has a 1/4" depression in the wide end. If the cubes are not filled out, adjust the machine to make larger ice cubes by turning the cube size control shaft clockwise. June 2001 Page 6 HOW IT WORKS: COMPONENT DESCRIPTION Cube Size Control The cube size control is located in front of the control box, behind the front panel. The sensing capillary tube of the cube size control is routed out of the control box into its bulb holder on the evaporator coil. It is a reverse acting temperature control with double throw contacts. Turning its knob all the way counterclockwise also shuts off the ice maker. The control determines the length of the freezing cycle and correspondingly the size of the cube. A lower setting will produce a smaller cube, and a higher setting will make a larger cube. The cube size control changes its contacts when the evaporator reaches its preset temperature, starting the harvest cycle. When the sensing tube of the cube size control reaches the high preset temperature, the contacts change again, restarting the freeze cycle. Harvest cycle The hot gas valve opens and hot refrigerant gas is discharged into the evaporator. The refrigerant, now a low pressure, low temperature vapor, flows into the accumulator, which traps excess liquid refrigerant. The vapor, now primarily a gas, goes through the suction line tube to the compressor where the cycle is repeated. EVAPORATOR ACCUMULATOR CAPILLARY TUBE SUCTION LINE DISCHARG E LINE CONDENSER LIQUID LINE STRAINER Refrigeration System Schematic June 2001 Page 10 COMPRESSOR FILTER-DRIER HOW IT WORKS: REFRIGERATION HARVEST CYCLE (When the cubes are released) The ice cubes have been formed in an inverted mold that was refrigerated. Now the refrigeration system will change to warm the cube mold and release the cubes. There, refrigerant vapor is compressed and flows from the compressor through the discharge line as a high temperature, high pressure gas. Before the gas gets to the condenser, it goes through a strainer, the strainer outlet is connected to two tubes, one of which leads to an electric valve, the hot gas solenoid. When this valve opens, the refrigerant gas follows the path of least resistance and flows through the tubing from the EVAPORATOR WRF535SWBB hot gas valve to the evaporator, where the ice cubes are frozen. At the evaporator, the high temperature gases are cooled by the cold temperatures of the cube mold, and condense into liquid, transferring heat to the mold which warms up and releases the cubes. The refrigerant, now a low pressure, low temperature vapor, flows into the accumulator, which traps excess liquid refrigerant. The vapor, now primarily a gas, goes through the suction line tube to the compressor where the cycle is repeated. ACCUMULATOR CAPILLARY TUBE SUCTION LINE HOT GAS SOLENOID (OPEN) DISCHARGE LINE CONDENSER LIQUID LINE STRAINER COMPRESSOR FILTER-DRIER June 2001 Page 11 WRF535SWBB OPERATION & ADJUSTMENT: OPERATING CHARACTERISTICS The information shown below covers a wide range of air and water temperatures. It is intended as a guideline only, and is based on data compiled from NEW CLEAN units. [. . . ] Operate the machine with the cleaning toggle switch in the Operation position for 4 minutes. Switch the cleaning toggle switch to the Cleaning position and operate the machine for 1 minute. After the fifth time rotate the control knob counter clockwise to the Off position. Pour sanitizer solution over the entire surface of the evaporator section and wash or spray the evaporator cover bottom with sanitizer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRF535SWBB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRF535SWBB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.