Detailed instructions for use are in the User's Guide.
[. . . ] Fuse Size 15
28. 56 X 18 X 20. 5
The finish is stainless steel with a galvanized back panel. Minimum circuit ampacity is used to determine wire size per national electric code. OPERATING REQUIREMENTS: MINIMUM MAXIMUM Air Temperature Water Temperature Water Pressure Voltage 500 F. 100 PSIG 126. 5V
Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance. [. . . ] After about 20 minutes the machine will begin to release the ice, this is called the harvest cycle. Observe the first cube harvest:
·Ice making
spray nozzles.
·Check the size of the ice cubes. Note: The normal size of the ice cube has a 1/4" depression in the wide end.
If the cubes are not filled out, adjust the machine to make larger ice cubes by turning the cube size control shaft clockwise. June 2001
Page 6
HOW IT WORKS:
COMPONENT DESCRIPTION
Cube Size Control The cube size control is located in front of the control box, behind the front panel. The sensing capillary tube of the cube size control is routed out of the control box into its bulb holder on the evaporator coil. It is a reverse acting temperature control with double throw contacts. Turning its knob all the way counterclockwise also shuts off the ice maker. The control determines the length of the freezing cycle and correspondingly the size of the cube. A lower setting will produce a smaller cube, and a higher setting will make a larger cube. The cube size control changes its contacts when the evaporator reaches its preset temperature, starting the harvest cycle. When the sensing tube of the cube size control reaches the high preset temperature, the contacts change again, restarting the freeze cycle. Harvest cycle The hot gas valve opens and hot refrigerant gas is discharged into the evaporator. The refrigerant, now a low pressure, low temperature vapor, flows into the accumulator, which traps excess liquid refrigerant. The vapor, now primarily a gas, goes through the suction line tube to the compressor where the cycle is repeated.
EVAPORATOR
ACCUMULATOR
CAPILLARY TUBE SUCTION LINE
DISCHARG E LINE
CONDENSER
LIQUID LINE
STRAINER Refrigeration System Schematic June 2001 Page 10
COMPRESSOR
FILTER-DRIER
HOW IT WORKS:
REFRIGERATION
HARVEST CYCLE (When the cubes are released) The ice cubes have been formed in an inverted mold that was refrigerated. Now the refrigeration system will change to warm the cube mold and release the cubes. There, refrigerant vapor is compressed and flows from the compressor through the discharge line as a high temperature, high pressure gas. Before the gas gets to the condenser, it goes through a strainer, the strainer outlet is connected to two tubes, one of which leads to an electric valve, the hot gas solenoid. When this valve opens, the refrigerant gas follows the path of least resistance and flows through the tubing from the
EVAPORATOR
WRF535SWBB
hot gas valve to the evaporator, where the ice cubes are frozen. At the evaporator, the high temperature gases are cooled by the cold temperatures of the cube mold, and condense into liquid, transferring heat to the mold which warms up and releases the cubes. The refrigerant, now a low pressure, low temperature vapor, flows into the accumulator, which traps excess liquid refrigerant. The vapor, now primarily a gas, goes through the suction line tube to the compressor where the cycle is repeated.
ACCUMULATOR
CAPILLARY TUBE SUCTION LINE
HOT GAS SOLENOID (OPEN)
DISCHARGE LINE
CONDENSER
LIQUID LINE
STRAINER
COMPRESSOR
FILTER-DRIER
June 2001 Page 11
WRF535SWBB
OPERATION & ADJUSTMENT: OPERATING CHARACTERISTICS
The information shown below covers a wide range of air and water temperatures. It is intended as a guideline only, and is based on data compiled from NEW CLEAN units. [. . . ] Operate the machine with the cleaning toggle switch in the Operation position for 4 minutes. Switch the cleaning toggle switch to the Cleaning position and operate the machine for 1 minute. After the fifth time rotate the control knob counter clockwise to the Off position. Pour sanitizer solution over the entire surface of the evaporator section and wash or spray the evaporator cover bottom with sanitizer. [. . . ]