User manual WHIRLPOOL WRS325FDAW WARRANTY INFORMATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WRS325FDAW. We hope that this WHIRLPOOL WRS325FDAW user guide will be useful to you.


WHIRLPOOL WRS325FDAW WARRANTY INFORMATION: Download the complete user guide (85 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WRS325FDAW ENERGY GUIDE (403 ko)
   WHIRLPOOL WRS325FDAW DIMENSION GUIDE (88 ko)
   WHIRLPOOL WRS325FDAW USE & CARE GUIDE (1362 ko)
   WHIRLPOOL WRS325FDAW INSTALLATION GUIDE (793 ko)

Manual abstract: user guide WHIRLPOOL WRS325FDAWWARRANTY INFORMATION

Detailed instructions for use are in the User's Guide.

[. . . ] Keep this manual for future reference. Note this symbol when it appears. It is an alert for important safety information on a potential hazard. August 1993 Page 1 WRS325FDAW FOR THE INSTALLER The WRS325FDAW is designed to fit the following Scotsman storage bins: · BH550 using bin top KBT14 or KBT20 · B90 with bin top KBT18. · BH900 using bin top KBT24 When installing a new system, check to be sure that you have everything you need before beginning: · Correct Bin · Correct Ice Machine · Correct Bin Top · All kits, legs, and information required for the specific job. SPECIFICATIONS: ICEMAKER Ice Type Refrigerant Refrigerant Max. Type Charge Size Circuit Ampacity WRS325FDAWE-1A 21" x 24" x 27" 115/60/1 Nugget R-404a 208 ounces 35 22. 5 * Minimum Circuit Ampacity is used to determine wire size and type per National Electric Code. [. . . ] Repeat steps 8-11 using the sanitizer solution in place of the cleaning solution. Continue ice making for at least 15 minutes, to flush out any cleaning solution. ///////////////////////////////CAUTION/////////////////////////////// DO NOT USE any ice produced from the cleaning solution. /////////////////////////////////////////////////////////////////////////////// 15. Add warm water to the ice storage bin and thoroughly wash and rinse all surfaces within the bin. Sanitize the bin interior with an approved sanitizer using the directions for that sanitizer. Replace the panels. WRS325FDAW MAINTENANCE AND CLEANING ICE CHUTE Electrical Shock Hazard. The bin control uses devices that sense light, therefore they must be kept clean enough so that they can "see". At least twice a year, remove the bin control sensors from the base of the ice chute, and wipe the inside clean, as illustrated. The ice machine senses water level by a probe located in the water reservoir. At least twice a year, the probe should be removed from the reservoir, and the tip wiped clean of mineral build-up. SLIDE UP TO REMOVE ICE LEVEL SENSORS SLIDE LEFT TO REMOVE Inspect the assembly, looking for wear 4. If the line side has the correct voltage and the load side does not, replace the transformer. If the transformer is good, and the bin empty light is OFF, check the ice level sensors. Look through the ice chute "eye" hole for something blocking the ice chute. Unplug "opto trans" and "LED" connectors from the circuit board. Plug "opto trans" and "LED" connectors from the Scotsman Electronic Control Tester Model NM1 into the circuit board (see page 36). Move the "bin full" switch on the tester to the full position. The bin full light on the tester should be ON, if not, replace the circuit board. If the bin full light on the tester is ON, move the tester switch to "bin empty" the light on the tester should go OFF and the bin empty light on the circuit board should go ON. If it does as above, and the machine still does not run, replace the ice level sensors. If the transformer is fine, and the "no water" light is ON, check the water level sensor. Remove the water level sensor from the reservoir and clean the tip if dirty. [. . . ] Allen · If gauges must be used, use very short hoses Wrench to minimize refrigerant discharged into the air. · Refrigerant should not be added except as a way to determine the proper operation of the product. If the system was low on refrigerant, Torque Stem to there is a leak, and it must be found and Torque 6-8 ft. · This system has a critical charge, it must be Torque Stem Cap to 8-12 ft. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRS325FDAW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRS325FDAW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.