User manual WHISTLER PP750

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHISTLER PP750. We hope that this WHISTLER PP750 user guide will be useful to you.


WHISTLER PP750 : Download the complete user guide (147 Ko)

Manual abstract: user guide WHISTLER PP750

Detailed instructions for use are in the User's Guide.

[. . . ] PP750 Manual 3/6/02 2:25 PM Page 1 OWNER'S MANUAL 750 WATT HIGH SURGE POWER INVERTER THE WHISTLER GROUP CORPORATE HEADQUARTERS 13016 N. Bentonville, AR 72712 TEL (479) 273-6012 FX (479) 273-2927 www. whistlergroup. com PRODUCT DEVELOPMENT CENTER 25 Industrial Ave. Chelmsford, MA 01824 TEL (978) 244-1400 FX (978) 244-1491 CUSTOMER RETURN CENTER 1201 N. Rogers, AR 72756 Consumer Relations Tel (800) 531-0004 Email: info@whistlergroup. com P/N PP750MAN/2 ©WHISTLER 2002 PP750 Manual 3/6/02 2:25 PM Page 3 INTRODUCTION If you have questions concerning the operation of this Whistler product please call consumer relations: Dear Whistler Owner, For many of us, a vehicle is more than just transportation. [. . . ] Note: · As indicated in Step 7 above, the audible alarm may make a momentary "chirp" when the inverter is turned OFF (O). The same alarm may also sound when the inverter is being connected to or disconnected from the 12 volt power source. · The use of an extension cord from the inverter to the appliance or equipment being operated will not significantly decrease the power being generated by the inverter. For best operating results, the extension cord should be no more than 50 feet long. · Check frequently to ensure that the input and output connections are secure. Loose connections may damage the inverter, the power source, or may generate excessive heat. 7. OPERATION Important Information on Battery Chargers Using your inverter to recharge units designed to charge such portable equipment as power tools, flashlights, video cameras and laptop computers may cause damage to the inverter or the charging unit. Check with the appliance manufacturer for compatibility with sine wave inverters if you're unsure. Although we advise against it, if you attempt to recharge a charging unit, monitor the temperature of the charging unit for approximately 10 minutes. If the charging unit becomes unusually warm, disconnect it from the inverter immediately. With reasonable care, it should not be necessary to replace the fuse(s) in your inverter. Thermal Cut Off: Automatic shut down when the internal circuit temperature exceeds standard design parameters for safe operation. 12 13 PP750 Manual 3/6/02 2:25 PM Page 17 ADDITIONAL FEATURES 2. Low Battery Voltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power source drops below 10. 5 volts, an audible tone will be heard. b) The inverter will automatically shut down when the input voltage drops below 9. 5 volts. In the event of automatic shut down or continuous audible alarm, turn the inverter rocker switch to the OFF (O) position until the source of the related problem has been identified and resolved. Wall Mounting: Whistler inverters have provisions for wall mounting; two slotted holes in the handle area and a notched area at the power cord end allow for easy wall mounting of the unit. Your Whistler GO AC inverter will work best when placed on a reasonably flat surface. When driving with the inverter in operation, make certain that neither the inverter nor the power cords will impede safe operation of your vehicle. Keep the unit and all cords clear of the steering wheel, gas, brake and clutch pedals and gear shift. · CARE AND MAINTENANCE To maintain your inverter in proper working condition, note the following important safety precautions: · MOISTURE. Do not operate the inverter if you, the inverter, the device being operated or any other surfaces that may come in contact with any power sources are wet. Water and many other liquids can conduct electricity which may lead to serious injury or death. [. . . ] Three 3 Prong Fuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three 35 Amp (Spade Type) Approximate Dimensions. . . . . 14" H x 7. 25" W x 3" D Approximate Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. 5 lbs Problem TV does not turn on 22 23 PP750 Manual 3/6/02 2:25 PM Page 27 WARRANTY Consumer Warranty The Whistler PP750AC is warranteed to the original purchaser for a period of two years, from the date of original purchase, against all defects in materials and workmanship. This limited warranty is void if the unit is abused, modified, installed improperly, had its housing removed, or has a missing serial number. There are no express warranties covering this product other than those set forth in this warranty. All express or implied warranties for this product are limited to two years. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHISTLER PP750




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHISTLER PP750 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.